    keyword=End_of_Run_3707
    ****************************
     Run Number: 3707
     End of Run Comment:
    Run_type=Cosmics,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, -- 0.5 cm thin detector
     
    
    PRESCALE FACTORS:ps1=6   ps2=99999   ps3=9999   ps4=2   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 339488       
    TIME     : 6.791 mins  
    
    DEAD TIME:   4.04%      
    
    TRIGGER RATES:   PRES/REAL
    T1:785.7/4714.4 Hz   T2: 0.0/265.5 Hz   T3: 0.0/0.0  Hz   T4:82.6/165.1 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 320143/1920861  T2:      1/108174   T3:      0/0        T4:  33643/67287    T5:      0/0        T6:      0/0        T8:      6/417223   
    
    AVERAGE CURRENT
    BCM x1 : 7.9458 uA  BCM x3 : 7.9496 uA  BCM x10: 8.0140 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.003233       BCM u3 : 0.003234       BCM u10: 0.003258       
    
    BCM d1 : 0.003242       BCM d3 : 0.003244       BCM d10: 0.003273       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3707 at Thu Jan 31 08:12:12 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.499983
    Left Arm arm angle : 20.4276
    Right Arm D1 momentum : 0.967942
    Right Arm arm angle : 15.9953
    HALLA:p : 957.411
    HALLA:dpp : -9.72144e-05
    Tiefenbach Hall A energy : 957.411
    Left Arm Top VDC Current : -2.19727
    Left Arm Bottom VDC Current : 2.29492
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03178
    Left Arm Q2 gauss meter : 0.08559
    Left Arm Q2 power supply current : 215.299
    Left Arm Q2 momentum : 0.499999
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.747
    Left Arm D1 momentum : 0.499983
    Left Arm D1 NMR : 0.185234
    Left Arm Q3 gauss meter : -0.10095
    Left Arm Q3 power supply current : 199.059
    Left Arm Q3 momentum : 0.5
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.01836
    Right Arm Q2 power supply current : 416.563
    Right Arm Q2 momentum : 0.967925
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967941
    Right Arm D1 NMR : 0.359191
    Right Arm Q3 power supply current : 424.167
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 7.91718
    Current on Unser monitor : 19.3406
    Current on Upstream bcm : 7.9241
    Current on Downstream bcm : 7.91026
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 7.86347
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.409
    Hall A momentum orbit correction (dpp) : -9.88313e-05
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.409
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.10261
    IPM1C12.XPOS : -0.0307872
    IPM1H04A.XPOS : 0.00661522
    IPM1H04A.YPOS : 0.922996
    IPM1H04B.XPOS : 0.00055939
    IPM1H04B.YPOS : 0.985887
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.140137
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : -0.145996
    SLI data valid? : Yes
    SLI horiz size mm : 0.188008
    SLI Energy spread *10^5 : 4.7002
    SLI x position : 1.50559
    SLI vert. size mm : 0.278602
    SLI y position : 1.53239
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.46
    temperature loop 1(3) : 96.89
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.35
    temperature loop 3(3) : 19.59
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.0118473
    HPH H2 loop 3 : 0.011068
    -----