     Run Number: 3708
     End of Run Comment:
    Run_type=Cosmics,target_type=Carbon,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Carbon, -- 0.5 cm thin detector, Current 8uA
     
    
    PRESCALE FACTORS:ps1=6   ps2=99999   ps3=9999   ps4=2   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 705284       
    TIME     : 2.525 mins  
    
    DEAD TIME:  53.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1:9899.5/59397.0 Hz   T2: 0.0/509.8 Hz   T3: 0.0/0.0  Hz   T4: 4.0/8.0  Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:1499997/8999982  T2:      0/77244    T3:      0/0        T4:    607/1215     T5:      0/0        T6:      0/0        T8:      2/155159   
    
    AVERAGE CURRENT
    BCM x1 : 8.1410 uA  BCM x3 : 8.1449 uA  BCM x10: 8.2107 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.001231       BCM u3 : 0.001232       BCM u10: 0.001241       
    
    BCM d1 : 0.001236       BCM d3 : 0.001236       BCM d10: 0.001247       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3708 at Thu Jan 31 08:22:48 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.499983
    Left Arm arm angle : 20.4276
    Right Arm D1 momentum : 0.967941
    Right Arm arm angle : 14.9999
    HALLA:p : 957.407
    HALLA:dpp : -0.000101719
    Tiefenbach Hall A energy : 957.407
    Left Arm Top VDC Current : 3.07617
    Left Arm Bottom VDC Current : 0.341797
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03178
    Left Arm Q2 gauss meter : 0.08554
    Left Arm Q2 power supply current : 215.3
    Left Arm Q2 momentum : 0.5
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.745
    Left Arm D1 momentum : 0.499983
    Left Arm D1 NMR : 0.185234
    Left Arm Q3 gauss meter : -0.10095
    Left Arm Q3 power supply current : 199.059
    Left Arm Q3 momentum : 0.499999
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.771
    Right Arm Q1 gauss meter : -0.018361
    Right Arm Q2 power supply current : 416.563
    Right Arm Q2 momentum : 0.967925
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967941
    Right Arm D1 NMR : 0.359191
    Right Arm Q3 power supply current : 424.167
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 8.02842
    Current on Unser monitor : 21.4543
    Current on Upstream bcm : 8.01017
    Current on Downstream bcm : 8.04667
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 7.95819
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.411
    Hall A momentum orbit correction (dpp) : -9.71733e-05
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.411
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.08983
    IPM1C12.XPOS : 0.0117943
    IPM1H04A.XPOS : 0.0150511
    IPM1H04A.YPOS : 0.938383
    IPM1H04B.XPOS : 0.00273252
    IPM1H04B.YPOS : 1.00377
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.13916
    HacL_HPE1313A:0_Ch55 : 23.7305
    HacL_HPE1313A:0_Ch54 : -0.14502
    SLI data valid? : Yes
    SLI horiz size mm : 0.0592234
    SLI Energy spread *10^5 : 1.48059
    SLI x position : 1.50559
    SLI vert. size mm : 0.12909
    SLI y position : 1.53239
    -----
    Target : Carbon
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36.5
    Encoder position : 1.55285e+06
    Target type : 1.55285e+06
    temperature loop 1(1) : 110.46
    temperature loop 1(3) : 96.8
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.35
    temperature loop 3(3) : 19.59
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00123869
    HPH H2 loop 3 : 0.011068
    -----