Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 10:00:19 on January 31, 2008

    Entry number 228299

    keyword=End_of_Run_6044
    ****************************
     Run Number: 6044
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.500,leftarm_theta=20.428,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_l.txt
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=1   ps4=2   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 15001        
    TIME     : 10.258 mins  
    
    DEAD TIME: -20.82%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.0/9.9  Hz   T2: 0.0/0.0  Hz   T3:15.2/15.2 Hz   T4: 5.0/10.0 Hz   T5: 0.0/0.0  Hz   T6: 0.0/24.4 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:      0/6106     T2:      0/0        T3:   9325/9325     T4:   3081/6163     T5:      0/0        T6:      0/15001    T7:      0/0        T8:      9/630255   T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 0.0011 uA  BCM x3 : -0.0000uA  BCM x10: -0.0006uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 9.935E-07      BCM u3 : 6.486E-07      BCM u10: 5.627E-07      
    
    BCM d1 : 3.323E-07      BCM d3 : -6.766E-07     BCM d10: -1.343E-06     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6044 at Thu Jan 31 10:00:15 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.500002
    Left Arm arm angle : 20.4276
    Right Arm D1 momentum : 0.967941
    Right Arm arm angle : 14.9999
    HALLA:p : 957.504
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 957.504
    Left Arm Top VDC Current : 4.83398
    Left Arm Bottom VDC Current : 1.26953
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03178
    Left Arm Q2 gauss meter : 0.08557
    Left Arm Q2 power supply current : 215.303
    Left Arm Q2 momentum : 0.500007
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.751
    Left Arm D1 momentum : 0.500003
    Left Arm D1 NMR : 0.185241
    Left Arm Q3 gauss meter : -0.10096
    Left Arm Q3 power supply current : 199.059
    Left Arm Q3 momentum : 0.499999
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018358
    Right Arm Q2 power supply current : 416.566
    Right Arm Q2 momentum : 0.967932
    Right Arm Q2 gauss meter : 0.2183
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.96794
    Right Arm D1 NMR : 0.359191
    Right Arm Q3 power supply current : 424.188
    Right Arm Q3 momentum : 1.06604
    Right Arm Q3 gauss meter : 0.18957
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0237921
    Current on Unser monitor : 12.6423
    Current on Upstream bcm : 0.0354847
    Current on Downstream bcm : 0.0120995
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 0.00312079
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.504
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.504
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.138672
    HacL_HPE1313A:0_Ch55 : 23.6328
    HacL_HPE1313A:0_Ch54 : -0.145508
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.02733
    SLI vert. size mm : 0
    SLI y position : 1.40469
    -----
    Target : Carbon
    Vacuum Pressure : 4.14435e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 1.55285e+06
    Target type : 1.55285e+06
    temperature loop 1(1) : 110.36
    temperature loop 1(3) : 96.6
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.37
    temperature loop 3(3) : 19.62
    Heat exchange H2 : 19.1
    HPH He loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721