Run Number: 3716
End of Run Comment:
Run_type=Cosmics,target_type=Carbon,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Carbon, -- 0.5 cm thin detector, Current 3uA
PRESCALE FACTORS:ps1=1 ps2=1 ps3=9999 ps4=1 ps5=99999 ps6=65535 ps7=65535 ps8=65535
EVENTS : 876714
TIME : 12.053 mins
DEAD TIME: 96.84%
TRIGGER RATES: PRES/REAL
T1:38250.1/38250.1 Hz T2:127.2/127.2 Hz T3: 0.0/0.0 Hz T4: 0.0/0.0 Hz T5: 0.0/0.0 Hz T6: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:27660730/27660730 T2: 91990/91990 T3: 0/0 T4: 0/0 T5: 0/0 T6: 0/0 T8: 11/740511
AVERAGE CURRENT
BCM x1 : 1.2270 uA BCM x3 : 1.2272 uA BCM x10: 1.2368 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.0008851 BCM u3 : 0.0008854 BCM u10: 0.000892
BCM d1 : 0.0008894 BCM d3 : 0.0008895 BCM d10: 0.0008967
****************************
End-of-run EPICS data for Run Number 3716 at Thu Jan 31 12:27:19 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.500002
Left Arm arm angle : 20.4276
Right Arm D1 momentum : 0.967938
Right Arm arm angle : 12.4999
HALLA:p : 957.417
HALLA:dpp : -9.09531e-05
Tiefenbach Hall A energy : 957.417
Left Arm Top VDC Current : -1.41602
Left Arm Bottom VDC Current : 2.88086
Left Arm Q1 momentum : 0.50004
Left Arm Q1 power supply : 376.196
Left Arm Q1 gauss meter : -0.03177
Left Arm Q2 gauss meter : 0.08557
Left Arm Q2 power supply current : 215.299
Left Arm Q2 momentum : 0.499998
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 164.754
Left Arm D1 momentum : 0.500002
Left Arm D1 NMR : 0.185241
Left Arm Q3 gauss meter : -0.10095
Left Arm Q3 power supply current : 199.058
Left Arm Q3 momentum : 0.499998
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.967936
Right Arm Q1 power supply : 727.771
Right Arm Q1 gauss meter : -0.018345
Right Arm Q2 power supply current : 416.562
Right Arm Q2 momentum : 0.967923
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 330.967
Right Arm D1 momentum : 0.967937
Right Arm D1 NMR : 0.35919
Right Arm Q3 power supply current : 424.166
Right Arm Q3 momentum : 1.06599
Right Arm Q3 gauss meter : 0.18956
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 5.04725
Current on Unser monitor : 17.2137
Current on Upstream bcm : 5.033
Current on Downstream bcm : 5.0615
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 5.02938
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.415
Hall A momentum orbit correction (dpp) : -9.26214e-05
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.415
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.14318
IPM1C12.XPOS : -0.000138044
IPM1H04A.XPOS : -0.0426171
IPM1H04A.YPOS : 0.0798951
IPM1H04B.XPOS : 0.0416411
IPM1H04B.YPOS : -0.0640521
Left Arm Collimator : 0.87168
HacL_HPE1313A:0_Ch58 : -0.135742
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.152832
SLI data valid? : Yes
SLI horiz size mm : 0.413254
SLI Energy spread *10^5 : 10.3314
SLI x position : 1.50559
SLI vert. size mm : 0.250352
SLI y position : 1.53239
-----
Target : Carbon
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 1.55285e+06
Target type : 1.55285e+06
temperature loop 1(1) : 110.31
temperature loop 1(3) : 96.58
Heat exchange He : 92.8
temperature loop 3(1) : 19.31
temperature loop 3(3) : 19.55
Heat exchange H2 : 19
HPH He loop 1 : 0.0540192
HPH He loop 2 : 0.00710569
HPH H2 loop 3 : 0.00293052
-----