User name D. Parno
Log entry time 12:47:15 on January31,2008
Entry number 228323
This entry is a followup to: 228155
keyword=No asymmetry for beam outside Compton chicane
FADC integration run 60337 was taken with the Compton laser off and the
electron beam NOT routed through the Compton chicane. I calculated all three
accumulator asymmetries (acc1, acc3, acc5 -- see Fig. 1) and found that they
were consistent with zero, as one would hope.
Note that, although the laser diode was turned off, the only asymmetry
histograms that were filled were for cavity "on." The cut was made on the
real-time cavity power variable. Fig. 2 shows a plot of the EPICS cavity power
variable, which shows a mean cavity power of 68 mW. This is consistent with the
values EPICS is showing today for a laser diode that is off. This seems to
indicate a problem with the real-time variable.
FIGURE 1