Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 15:21:58 on January 31, 2008

    Entry number 228346

    keyword=End_of_Run_3721
    ****************************
     Run Number: 3721
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=12.5,rightarm_colli=out,comment_text=Tantalum target -- 0.5 cm thin detector, Current 5uA T1 triggers only
     
    
    PRESCALE FACTORS:ps1=10   ps2=999999   ps3=9999   ps4=999999   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 866931       
    TIME     : 10.626 mins  
    
    DEAD TIME:   0.82%      
    
    TRIGGER RATES:   PRES/REAL
    T1:1371.1/13710.9 Hz   T2: 0.0/170.3 Hz   T3: 0.0/0.0  Hz   T4: 0.0/870.7 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 874122/8741228  T2:      0/108561   T3:      0/0        T4:      0/555100   T5:      0/0        T6:      0/0        T8:      9/652840   
    
    AVERAGE CURRENT
    BCM x1 : 4.9343 uA  BCM x3 : 4.9373 uA  BCM x10: 4.9773 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.00314        BCM u3 : 0.003141       BCM u10: 0.003164       
    
    BCM d1 : 0.003152       BCM d3 : 0.003154       BCM d10: 0.003182       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3721 at Thu Jan 31 15:21:55 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.500001
    Left Arm arm angle : 20.4276
    Right Arm D1 momentum : 0.967937
    Right Arm arm angle : 12.4999
    HALLA:p : 957.404
    HALLA:dpp : -0.000104313
    Tiefenbach Hall A energy : 957.404
    Left Arm Top VDC Current : 1.66016
    Left Arm Bottom VDC Current : 3.66211
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03177
    Left Arm Q2 gauss meter : 0.08556
    Left Arm Q2 power supply current : 215.301
    Left Arm Q2 momentum : 0.500003
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.755
    Left Arm D1 momentum : 0.500001
    Left Arm D1 NMR : 0.185241
    Left Arm Q3 gauss meter : -0.10095
    Left Arm Q3 power supply current : 199.058
    Left Arm Q3 momentum : 0.499997
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967865
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018343
    Right Arm Q2 power supply current : 416.563
    Right Arm Q2 momentum : 0.967925
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.966
    Right Arm D1 momentum : 0.967937
    Right Arm D1 NMR : 0.35919
    Right Arm Q3 power supply current : 424.168
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 4.92107
    Current on Unser monitor : 18.0435
    Current on Upstream bcm : 4.91472
    Current on Downstream bcm : 4.92741
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 4.92906
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.405
    Hall A momentum orbit correction (dpp) : -0.000103256
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.405
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.12514
    IPM1C12.XPOS : 0.00162464
    IPM1H04A.XPOS : -0.0939619
    IPM1H04A.YPOS : 0.0701442
    IPM1H04B.XPOS : -0.0929698
    IPM1H04B.YPOS : -0.01603
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.135254
    HacL_HPE1313A:0_Ch55 : 23.584
    HacL_HPE1313A:0_Ch54 : -0.15332
    SLI data valid? : Yes
    SLI horiz size mm : 0.339523
    SLI Energy spread *10^5 : 8.48809
    SLI x position : 1.49068
    SLI vert. size mm : 0.395625
    SLI y position : 1.51737
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : -72740
    Target type : -72740
    temperature loop 1(1) : 110.4
    temperature loop 1(3) : 96.7
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.22
    temperature loop 3(3) : 19.46
    Heat exchange H2 : 18.9
    HPH He loop 1 : 0.0970926
    HPH He loop 2 : 0.00356948
    HPH H2 loop 3 : 0.00634721
    -----