Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 15:37:10 on January 31, 2008

    Entry number 228349

    keyword=End_of_Run_3722
    ****************************
     Run Number: 3722
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=12.5,rightarm_colli=out,comment_text=Tantalum target -- 0.5 cm thin detector, pulser trigger only
     
    
    PRESCALE FACTORS:ps1=9999999   ps2=999999   ps3=9999   ps4=999999   ps5=99999   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : 759288       
    TIME     : 12.358 mins  
    
    DEAD TIME:  -0.01%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.0/12909.2 Hz   T2: 0.0/158.6 Hz   T3: 0.0/0.0  Hz   T4: 0.0/808.0 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8:1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:      0/9572048  T2:      0/117605   T3:      0/0        T4:      0/599136   T5:      0/0        T6:      0/0        T8: 759288/759288   
    
    AVERAGE CURRENT
    BCM x1 : 4.6641 uA  BCM x3 : 4.6668 uA  BCM x10: 4.7046 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.003451       BCM u3 : 0.003453       BCM u10: 0.003478       
    
    BCM d1 : 0.003465       BCM d3 : 0.003468       BCM d10: 0.003499       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3722 at Thu Jan 31 15:37:06 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.500001
    Left Arm arm angle : 20.4276
    Right Arm D1 momentum : 0.967938
    Right Arm arm angle : 12.4999
    HALLA:p : 957.504
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 957.504
    Left Arm Top VDC Current : 1.07422
    Left Arm Bottom VDC Current : 0.878906
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03177
    Left Arm Q2 gauss meter : 0.08553
    Left Arm Q2 power supply current : 215.301
    Left Arm Q2 momentum : 0.500001
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.751
    Left Arm D1 momentum : 0.500001
    Left Arm D1 NMR : 0.185241
    Left Arm Q3 gauss meter : -0.10096
    Left Arm Q3 power supply current : 199.058
    Left Arm Q3 momentum : 0.499997
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018349
    Right Arm Q2 power supply current : 416.563
    Right Arm Q2 momentum : 0.967924
    Right Arm Q2 gauss meter : 0.2183
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967938
    Right Arm D1 NMR : 0.35919
    Right Arm Q3 power supply current : 424.167
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0242266
    Current on Unser monitor : 12.6853
    Current on Upstream bcm : 0.0358329
    Current on Downstream bcm : 0.0126202
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 303.387
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.504
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.504
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.135254
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : -0.152832
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.49814
    SLI vert. size mm : 0
    SLI y position : 1.05164
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72740
    Target type : -72740
    temperature loop 1(1) : 110.39
    temperature loop 1(3) : 96.51
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.23
    temperature loop 3(3) : 19.46
    Heat exchange H2 : 18.9
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00356948
    HPH H2 loop 3 : 0.011068
    -----