    keyword=End_of_Run_3723
    ****************************
     Run Number: 3723
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=12.5,rightarm_colli=out,comment_text=Tantalum target -- 0.5 cm thin detector, pulser trigger only
     
    
    PRESCALE FACTORS:ps1=9999999   ps2=999999   ps3=9999   ps4=999999   ps5=99999   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : 675952       
    TIME     : 11.002 mins  
    
    DEAD TIME:  -0.01%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.0/64923.6 Hz   T2: 0.0/680.2 Hz   T3: 0.0/0.0  Hz   T4: 0.0/4082.4 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8:1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:      4/42856285  T2:      0/449027   T3:      0/0        T4:      2/2694774  T5:      0/0        T6:      0/0        T8: 675946/675946   
    
    AVERAGE CURRENT
    BCM x1 : 23.7207uA  BCM x3 : 23.7246uA  BCM x10: 23.8243uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01562        BCM u3 : 0.01563        BCM u10: 0.01573        
    
    BCM d1 : 0.01569        BCM d3 : 0.01569        BCM d10: 0.01572        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3723 at Thu Jan 31 15:49:20 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.500001
    Left Arm arm angle : 20.4276
    Right Arm D1 momentum : 0.967937
    Right Arm arm angle : 12.4999
    HALLA:p : 957.406
    HALLA:dpp : -0.000102175
    Tiefenbach Hall A energy : 957.405
    Left Arm Top VDC Current : -2.19727
    Left Arm Bottom VDC Current : 0.634766
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03178
    Left Arm Q2 gauss meter : 0.08558
    Left Arm Q2 power supply current : 215.3
    Left Arm Q2 momentum : 0.500001
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.753
    Left Arm D1 momentum : 0.500001
    Left Arm D1 NMR : 0.185241
    Left Arm Q3 gauss meter : -0.10096
    Left Arm Q3 power supply current : 199.058
    Left Arm Q3 momentum : 0.499997
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967865
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018361
    Right Arm Q2 power supply current : 416.562
    Right Arm Q2 momentum : 0.967923
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.966
    Right Arm D1 momentum : 0.967938
    Right Arm D1 NMR : 0.35919
    Right Arm Q3 power supply current : 424.166
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 24.889
    Current on Unser monitor : 36.8657
    Current on Upstream bcm : 24.9084
    Current on Downstream bcm : 24.8695
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 24.6517
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.402
    Hall A momentum orbit correction (dpp) : -0.000106539
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.402
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.12558
    IPM1C12.XPOS : 0.00138131
    IPM1H04A.XPOS : -0.0811085
    IPM1H04A.YPOS : 0.0921291
    IPM1H04B.XPOS : -0.0964085
    IPM1H04B.YPOS : 0.0105606
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.135742
    HacL_HPE1313A:0_Ch55 : 23.6328
    HacL_HPE1313A:0_Ch54 : -0.152832
    SLI data valid? : Yes
    SLI horiz size mm : 0.184792
    SLI Energy spread *10^5 : 4.61979
    SLI x position : 1.50559
    SLI vert. size mm : 0.158919
    SLI y position : 1.53239
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72740
    Target type : -72740
    temperature loop 1(1) : 110.4
    temperature loop 1(3) : 96.68
    Heat exchange He : 92.7
    temperature loop 3(1) : 19.23
    temperature loop 3(3) : 19.47
    Heat exchange H2 : 18.9
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00634721
    -----