NEXT
User name a-onl
Log entry time 16:01:33 on January 31, 2008
Entry number 228358
keyword=End_of_Run_3724
****************************
Run Number: 3724
End of Run Comment:
Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=12.5,rightarm_colli=out,comment_text=Tantalum target -- 0.5 cm thin detector, 25 uA Stack triggers only at 100 mV
PRESCALE FACTORS:ps1=9999999 ps2=999999 ps3=9999 ps4=2 ps5=99999 ps6=65535 ps7=65535 ps8=65535
EVENTS : 1006126
TIME : 10.865 mins
DEAD TIME: 12.83%
TRIGGER RATES: PRES/REAL
T1: 0.0/57941.2 Hz T2: 0.0/588.5 Hz T3: 0.0/0.0 Hz T4:1770.7/3541.5 Hz T5: 0.0/0.0 Hz T6: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 3/37770908 T2: 0/383653 T3: 0/0 T4:1154320/2308640 T5: 0/0 T6: 0/0 T8: 10/667529
AVERAGE CURRENT
BCM x1 : 21.1470uA BCM x3 : 21.1503uA BCM x10: 21.2382uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01375 BCM u3 : 0.01375 BCM u10: 0.01385
BCM d1 : 0.01382 BCM d3 : 0.01382 BCM d10: 0.01384
****************************
End-of-run EPICS data for Run Number 3724 at Thu Jan 31 16:01:29 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.500001
Left Arm arm angle : 20.4276
Right Arm D1 momentum : 0.967938
Right Arm arm angle : 12.4999
HALLA:p : 957.407
HALLA:dpp : -0.000100746
Tiefenbach Hall A energy : 957.408
Left Arm Top VDC Current : 3.85742
Left Arm Bottom VDC Current : 4.05273
Left Arm Q1 momentum : 0.50004
Left Arm Q1 power supply : 376.143
Left Arm Q1 gauss meter : -0.03178
Left Arm Q2 gauss meter : 0.08558
Left Arm Q2 power supply current : 215.301
Left Arm Q2 momentum : 0.500002
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 164.751
Left Arm D1 momentum : 0.500002
Left Arm D1 NMR : 0.185241
Left Arm Q3 gauss meter : -0.10095
Left Arm Q3 power supply current : 199.058
Left Arm Q3 momentum : 0.499997
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.967936
Right Arm Q1 power supply : 727.825
Right Arm Q1 gauss meter : -0.01835
Right Arm Q2 power supply current : 416.565
Right Arm Q2 momentum : 0.967929
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 330.967
Right Arm D1 momentum : 0.967938
Right Arm D1 NMR : 0.35919
Right Arm Q3 power supply current : 424.169
Right Arm Q3 momentum : 1.066
Right Arm Q3 gauss meter : 0.18956
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 25.0069
Current on Unser monitor : 36.9379
Current on Upstream bcm : 24.9896
Current on Downstream bcm : 25.0242
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 24.7341
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.402
Hall A momentum orbit correction (dpp) : -0.000106582
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.402
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.12383
IPM1C12.XPOS : 0.00400561
IPM1H04A.XPOS : -0.0858802
IPM1H04A.YPOS : 0.0822619
IPM1H04B.XPOS : -0.0928201
IPM1H04B.YPOS : -0.00362051
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.135254
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.152344
SLI data valid? : Yes
SLI horiz size mm : 0.142182
SLI Energy spread *10^5 : 3.55455
SLI x position : 1.50559
SLI vert. size mm : 0.167827
SLI y position : 1.53239
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 37
Encoder position : -72740
Target type : -72740
temperature loop 1(1) : 110.4
temperature loop 1(3) : 96.56
Heat exchange He : 92.8
temperature loop 3(1) : 19.22
temperature loop 3(3) : 19.45
Heat exchange H2 : 18.9
HPH He loop 1 : 0.0813417
HPH He loop 2 : 0.00710569
HPH H2 loop 3 : 0.00293052
-----