NEXT
User name a-onl
Log entry time 16:13:18 on January 31, 2008
Entry number 228366
keyword=Start_Run_3726,Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=12.5,rightarm_colli=out,comment_text=Tantalum target -- 0.5 cm thin detector, 50 uA pulser trigger
Run Timestamp: Thu Jan 31 16:10:54 EST 2008
Beginning-of-run EPICS data for Run Number 3726 at Thu Jan 31 16:13:08 EST 2008
Run_type=Test
target_type=Tantalum
beam_e0=0.956
beam_raster=on
leftarm_p=0.948
leftarm_theta=20.37
leftarm_colli=out
rightarm_p=0.96793
rightarm_theta=12.5
rightarm_colli=out
comment_text=Tantalum target -- 0.5 cm thin detector, 50 uA pulser trigger
; HRS Spectrometer DAQ on adaql2/a-onl account
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = S1.and.S2
; T2 = HAPPEX S0
; T3 = thin HAPPEX detector
; T4 = thick HAPPEX detector
; T8 = 1024 Hz pulser
; String should be one line, no spaces, ending in carriage return
ps1=9999999,ps2=999999,ps3=9999,ps4=999999,ps5=99999,ps6=65535,ps7=65535,ps8=1
Left Arm Q1 momentum : 0.50004
Left Arm Q1 power supply : 376.143
Left Arm Q1 gauss meter : -0.03178
Left Arm Q2 power supply current : 215.3
Left Arm Q2 momentum : 0.500002
Left Arm Q2 gauss meter : 0.08558
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 164.753
Left Arm D1 momentum : 0.500002
Left Arm D1 NMR : 0.185241
Left Arm Q3 power supply current : 199.058
Left Arm Q3 momentum : 0.499997
Left Arm Q3 gauss meter : -0.10096
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.17883
Right Arm Q1 momentum : 0.967865
Right Arm Q1 power supply : 727.771
Right Arm Q1 gauss meter : -0.018357
Right Arm Q2 power supply current : 416.562
Right Arm Q2 momentum : 0.967922
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 330.967
Right Arm D1 momentum : 0.967938
Right Arm D1 NMR : 0.35919
Right Arm Q3 power supply current : 424.167
Right Arm Q3 momentum : 1.06599
Right Arm Q3 gauss meter : 0.18956
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.3551
Left Arm Top VDC Current : 3.85742
Left Arm Bottom VDC Current : 3.95508
Left Arm Top VDC voltage : 3.99121
Left Arm Bottom VDC voltage : 4.00293
Right Arm Top VDC Current : -6.93359
Right Arm Bottom VDC Current : -9.57031
Right Arm Top VDC voltage : 3.99658
Right Arm Bottom VDC voltage : 3.99561
-----
Average current of the two cavities : 49.4334
Current on Unser monitor : 60.8272
Current on Upstream bcm : 49.5592
Current on Downstream bcm : 49.3077
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 48.9662
Hall C Current : 0
Hall A momentum (Tiefenbach) (HALLA:p) : 957.402
Hall A momentum orbit correction (dpp) : -0.000106867
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.402
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.44753
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 14.25
Raster Y width : 5
Left Arm Collimator : 0.871582
HacL_HPE1313A:0_Ch58 : -0.135742
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.15332
Left Arm Angle Floor Angle : 20.5
Left Arm Angle Vernier : 18.5
Left Arm Scattering Angle : 20.4276
Right Arm Arm Collimator : 0.863281
HacR_HPE1313A:0_Ch58 : -0.649414
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -1.02783
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
-----
IPM1C12.XPOS : -0.0308511
IPM1C12.YPOS : 0.0426888
IPM1H04A.XPOS : -0.0791196
IPM1H04A.YPOS : 0.0980846
IPM1H04B.XPOS : -0.102908
IPM1H04B.YPOS : -0.00437415
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : -46.0068
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 30.613
Laser attenuation Hall A : 290
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 35.5
Encoder position : -72740
Target type : -72740
temperature loop 1(1) : 110.4
temperature loop 1(2) : 110.16
temperature loop 1(3) : 96.5
Heat exchange He : 92.7
temperature loop 3(1) : 19.23
temperature loop 3(2) : 17.1
temperature loop 3(3) : 19.46
Heat exchange H2 : 18.9
pressure loop He : 17.6635
pressure loop H2 before : 20.9903
pressure loop H2 return : 21.5305
HPH He loop 1 : 0.0813417
HPH He loop 2 : 0.0118473
HPH H2 loop 3 : 0.00293052
-----
SLI data valid? : Yes
SLI horiz size mm : 0.171923
SLI Energy spread *10^5 : 4.29808
SLI x position : 1.50559
SLI vert. size mm : 0.166705
SLI y position : 1.53239
CSR NaI 251-270
CSR Slot13 ch0 : -1000.8
CSR Slot13 ch1 : -1806.7
CSR Slot13 ch2 : -1637.4
CSR Slot13 ch3 : -1603.5
CSR Slot13 ch4 : -1500.9
CSR Slot13 ch5 : -1735.8
CSR Slot13 ch6 : -1385.4
CSR Slot13 ch7 : -1486.9
CSR Slot13 ch8 : -1486.9
CSR Slot13 ch9 : -1801.9
CSR Slot13 ch10 : -1802
CSR Slot13 ch11 : -12
CSR Slot14 ch0 : -1580.6
CSR Slot14 ch1 : -1780.4
CSR Slot14 ch2 : -1682.2
CSR Slot14 ch3 : -1684.4
CSR Slot14 ch4 : -1559.2
CSR Slot14 ch5 : -1606
CSR Slot14 ch6 : -1684.6
CSR Slot14 ch7 : -1682.8
CSR Slot14 ch8 : -1686
CSR Slot14 ch9 : -1850.5
CSR Slot14 ch10 : -821
CSR Slot14 ch11 : -10.3
Left S2 HV
S2 Slot0 ch0 : -2335.9
S2 Slot0 ch1 : -2202.4
S2 Slot0 ch2 : -2153.5
S2 Slot0 ch3 : -2211.9
S2 Slot0 ch4 : -2425
S2 Slot0 ch5 : -2196.5
S2 Slot0 ch6 : -1940.7
S2 Slot0 ch7 : -1867.1
S2 Slot0 ch8 : -2035.8
S2 Slot0 ch9 : -1880.5
S2 Slot0 ch10 : -2060.7
S2 Slot0 ch11 : -1857.2
-----
Left S1 HV
S1 Slot1 ch0 : -1820.3
S1 Slot1 ch1 : -1810.5
S1 Slot1 ch2 : -1806.2
S1 Slot1 ch3 : -1775.5
S1 Slot1 ch4 : -1721.8
S1 Slot1 ch5 : -1900.4
S1 Slot1 ch6 : -1966.3
S1 Slot1 ch7 : -1725.9
S1 Slot1 ch8 : -1951.7
S1 Slot1 ch9 : -1775.9
S1 Slot1 ch10 : -1820.9
S1 Slot1 ch11 : -1860.9
-----
Left Cerenkov HV
GCER Slot2 ch0 : -1570.8
GCER Slot2 ch1 : -1477.2
GCER Slot2 ch2 : -1544.8
GCER Slot2 ch3 : -1461.3
GCER Slot2 ch4 : -1813.5
GCER Slot2 ch5 : -1985.9
GCER Slot2 ch6 : -1690.4
GCER Slot2 ch7 : -1775
GCER Slot2 ch8 : -2000.7
GCER Slot2 ch9 : -1635.4
GCER Slot2 ch10 : -14.2
GCER Slot2 ch11 : -20.6
-----
Left Pion Rejector Layer 1 HV
PRL1 Slot3 ch0 : -860.4
PRL1 Slot3 ch1 : -784.5
PRL1 Slot3 ch2 : -905.8
PRL1 Slot3 ch3 : -981.2
PRL1 Slot3 ch4 : -730.3
PRL1 Slot3 ch5 : -811
PRL1 Slot3 ch6 : -1081.3
PRL1 Slot3 ch7 : -990.8
PRL1 Slot3 ch8 : -810.5
PRL1 Slot3 ch9 : -790.9
PRL1 Slot3 ch10 : -829.5
PRL1 Slot3 ch11 : -785.3
PRL1 Slot4 ch0 : -870.1
PRL1 Slot4 ch1 : -901.3
PRL1 Slot4 ch2 : -750.8
PRL1 Slot4 ch3 : -895.1
PRL1 Slot4 ch4 : -921.7
PRL1 Slot4 ch5 : -821.2
PRL1 Slot4 ch6 : -836
PRL1 Slot4 ch7 : -826.4
PRL1 Slot4 ch8 : -1190.3
PRL1 Slot4 ch9 : -992.2
PRL1 Slot4 ch10 : -1030.9
PRL1 Slot4 ch11 : -861.4
PRL1 Slot5 ch0 : -1041.1
PRL1 Slot5 ch1 : -871
PRL1 Slot5 ch2 : -916.2
PRL1 Slot5 ch3 : -735.8
PRL1 Slot5 ch4 : -890.7
PRL1 Slot5 ch5 : -810.3
PRL1 Slot5 ch6 : -821.1
PRL1 Slot5 ch7 : -895.6
PRL1 Slot5 ch8 : -741.3
PRL1 Slot5 ch9 : -840.6
PRL1 Slot5 ch10 : -16.5
PRL1 Slot5 ch11 : -25.6
-----
Left Pion Rejector Layer 2 HV
PRL2 Slot9 ch0 : -920.5
PRL2 Slot9 ch1 : -881.3
PRL2 Slot9 ch2 : -800.1
PRL2 Slot9 ch3 : -869.9
PRL2 Slot9 ch4 : -810.9
PRL2 Slot9 ch5 : -941.5
PRL2 Slot9 ch6 : -851.5
PRL2 Slot9 ch7 : -890.6
PRL2 Slot9 ch8 : -810.6
PRL2 Slot9 ch9 : -780.6
PRL2 Slot9 ch10 : -821
PRL2 Slot9 ch11 : -851.4
PRL2 Slot10 ch0 : -755.7
PRL2 Slot10 ch1 : -812.4
PRL2 Slot10 ch2 : -871
PRL2 Slot10 ch3 : -900.8
PRL2 Slot10 ch4 : -881.4
PRL2 Slot10 ch5 : -871
PRL2 Slot10 ch6 : -815.2
PRL2 Slot10 ch7 : -824.8
PRL2 Slot10 ch8 : -760.3
PRL2 Slot10 ch9 : -715
PRL2 Slot10 ch10 : -911
PRL2 Slot10 ch11 : -781.3
PRL2 Slot11 ch0 : -1000.7
PRL2 Slot11 ch1 : -900.4
PRL2 Slot11 ch2 : -850.6
PRL2 Slot11 ch3 : -1079.9
PRL2 Slot11 ch4 : -1050.2
PRL2 Slot11 ch5 : -800
PRL2 Slot11 ch6 : -860.4
PRL2 Slot11 ch7 : -1031.3
PRL2 Slot11 ch8 : -911.3
PRL2 Slot11 ch9 : -880.3
PRL2 Slot11 ch10 : -12.9
PRL2 Slot11 ch11 : -24.7
-----