User name a-onl
Log entry time 16:20:41 on January 31, 2008
Entry number 228369
keyword=End_of_Run_3726
****************************
Run Number: 3726
End of Run Comment:
Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=12.5,rightarm_colli=out,comment_text=Tantalum target -- 0.5 cm thin detector, 50 uA pulser trigger
PRESCALE FACTORS:ps1=9999999 ps2=999999 ps3=9999 ps4=999999 ps5=99999 ps6=65535 ps7=65535 ps8=1
EVENTS : 568962
TIME : 9.316 mins
DEAD TIME: 0.59%
TRIGGER RATES: PRES/REAL
T1: 0.0/132145.2 Hz T2: 0.0/1348.3 Hz T3: 0.0/0.0 Hz T4: 0.0/7569.0 Hz T5: 0.0/0.0 Hz T6: 0.0/0.0 Hz T8:1024.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 7/73867471 T2: 0/753707 T3: 0/0 T4: 4/4230958 T5: 0/0 T6: 0/0 T8: 572403/572403
AVERAGE CURRENT
BCM x1 : 48.5217uA BCM x3 : 48.5061uA BCM x10: 41.9525uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.02707 BCM u3 : 0.02706 BCM u10: 0.02345
BCM d1 : 0.02718 BCM d3 : 0.02717 BCM d10: 0.02345
****************************
End-of-run EPICS data for Run Number 3726 at Thu Jan 31 16:20:37 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.500001
Left Arm arm angle : 20.4276
Right Arm D1 momentum : 0.967938
Right Arm arm angle : 12.4999
HALLA:p : 957.404
HALLA:dpp : -0.000104789
Tiefenbach Hall A energy : 957.404
Left Arm Top VDC Current : 0.195312
Left Arm Bottom VDC Current : -1.12305
Left Arm Q1 momentum : 0.50004
Left Arm Q1 power supply : 376.196
Left Arm Q1 gauss meter : -0.03177
Left Arm Q2 gauss meter : 0.08557
Left Arm Q2 power supply current : 215.301
Left Arm Q2 momentum : 0.500003
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 164.753
Left Arm D1 momentum : 0.500001
Left Arm D1 NMR : 0.185241
Left Arm Q3 gauss meter : -0.10095
Left Arm Q3 power supply current : 199.058
Left Arm Q3 momentum : 0.499998
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.967865
Right Arm Q1 power supply : 727.825
Right Arm Q1 gauss meter : -0.018342
Right Arm Q2 power supply current : 416.563
Right Arm Q2 momentum : 0.967924
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 330.967
Right Arm D1 momentum : 0.967938
Right Arm D1 NMR : 0.35919
Right Arm Q3 power supply current : 424.167
Right Arm Q3 momentum : 1.06599
Right Arm Q3 gauss meter : 0.18956
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.8061
Current on Unser monitor : 61.8571
Current on Upstream bcm : 49.8082
Current on Downstream bcm : 49.8041
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.2489
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.407
Hall A momentum orbit correction (dpp) : -0.000101283
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.407
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.44566
IPM1C12.XPOS : 0.003923
IPM1H04A.XPOS : -0.0941625
IPM1H04A.YPOS : 0.0771779
IPM1H04B.XPOS : -0.1097
IPM1H04B.YPOS : -0.00191033
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.135254
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.152832
SLI data valid? : Yes
SLI horiz size mm : 0.166895
SLI Energy spread *10^5 : 4.17238
SLI x position : 1.50559
SLI vert. size mm : 0.138625
SLI y position : 1.53239
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : -72740
Target type : -72740
temperature loop 1(1) : 110.41
temperature loop 1(3) : 96.56
Heat exchange He : 92.7
temperature loop 3(1) : 19.23
temperature loop 3(3) : 19.47
Heat exchange H2 : 18.9
HPH He loop 1 : 0.0813417
HPH He loop 2 : 0.00710569
HPH H2 loop 3 : 0.011068
-----