     Run Number: 3727
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=12.5,rightarm_colli=out,comment_text=Tantalum target -- 0.5 cm thin detector, 1 uA T1 T2 and T4 triggers
     
    
    PRESCALE FACTORS:ps1=10   ps2=1   ps3=9999   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 164013       
    TIME     : 5.646 mins  
    
    DEAD TIME:   8.65%      
    
    TRIGGER RATES:   PRES/REAL
    T1:293.3/2933.2 Hz   T2:70.3/70.3 Hz   T3: 0.0/0.0  Hz   T4:166.4/166.4 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:  99360/993604   T2:  23812/23812    T3:      0/0        T4:  56371/56371    T5:      0/0        T6:      0/0        T8:      5/346877   
    
    AVERAGE CURRENT
    BCM x1 : 1.0433 uA  BCM x3 : 1.0442 uA  BCM x10: 1.0524 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.0003524      BCM u3 : 0.0003525      BCM u10: 0.0003552      
    
    BCM d1 : 0.0003544      BCM d3 : 0.0003549      BCM d10: 0.0003578      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3727 at Thu Jan 31 16:28:11 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.500001
    Left Arm arm angle : 20.4276
    Right Arm D1 momentum : 0.967938
    Right Arm arm angle : 12.4999
    HALLA:p : 957.481
    HALLA:dpp : -2.38585e-05
    Tiefenbach Hall A energy : 957.481
    Left Arm Top VDC Current : 5.07812
    Left Arm Bottom VDC Current : 4.39453
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03179
    Left Arm Q2 gauss meter : 0.08557
    Left Arm Q2 power supply current : 215.301
    Left Arm Q2 momentum : 0.500003
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.751
    Left Arm D1 momentum : 0.500001
    Left Arm D1 NMR : 0.185241
    Left Arm Q3 gauss meter : -0.10096
    Left Arm Q3 power supply current : 199.058
    Left Arm Q3 momentum : 0.499997
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.771
    Right Arm Q1 gauss meter : -0.01836
    Right Arm Q2 power supply current : 416.564
    Right Arm Q2 momentum : 0.967927
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967938
    Right Arm D1 NMR : 0.35919
    Right Arm Q3 power supply current : 424.167
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 1.04987
    Current on Unser monitor : 13.5104
    Current on Upstream bcm : 1.05218
    Current on Downstream bcm : 1.05155
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 1.05953
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.484
    Hall A momentum orbit correction (dpp) : -2.09046e-05
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.484
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.48009
    IPM1C12.XPOS : -0.266049
    IPM1H04A.XPOS : -0.098952
    IPM1H04A.YPOS : 0.115575
    IPM1H04B.XPOS : -0.0792486
    IPM1H04B.YPOS : 0.0404882
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.135742
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : -0.15332
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.99752
    SLI vert. size mm : 0
    SLI y position : 1.00657
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72740
    Target type : -72740
    temperature loop 1(1) : 110.4
    temperature loop 1(3) : 96.58
    Heat exchange He : 92.7
    temperature loop 3(1) : 19.23
    temperature loop 3(3) : 19.46
    Heat exchange H2 : 18.9
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.0170928
    -----