    keyword=End_of_Run_6049
    ****************************
     Run Number: 6049
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.500,leftarm_theta=20.428,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_n.txt
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=1   ps4=2   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 100091       
    TIME     : 11.818 mins  
    
    DEAD TIME:  86.99%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 4.1/40938.0 Hz   T2: 0.0/0.0  Hz   T3:1036.6/1036.6 Hz   T4:44.1/88.2 Hz   T5: 0.0/0.0  Hz   T6: 0.0/141.2 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:   2903/29028210  T2:      0/0        T3: 735050/735050   T4:  31276/62552    T5:      0/0        T6:      1/100091   T7:      0/0        T8:     11/726096   T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 14.8565uA  BCM x3 : 14.9172uA  BCM x10: 13.0527uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01052        BCM u3 : 0.01051        BCM u10: 0.009263       
    
    BCM d1 : 0.01055        BCM d3 : 0.01064        BCM d10: 0.009248       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6049 at Thu Jan 31 16:34:47 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.500001
    Left Arm arm angle : 20.4276
    Right Arm D1 momentum : 0.967938
    Right Arm arm angle : 12.4999
    HALLA:p : 957.388
    HALLA:dpp : -0.000151144
    Tiefenbach Hall A energy : 957.359
    Left Arm Top VDC Current : -2.05078
    Left Arm Bottom VDC Current : 4.29688
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03178
    Left Arm Q2 gauss meter : 0.08558
    Left Arm Q2 power supply current : 215.3
    Left Arm Q2 momentum : 0.500001
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.755
    Left Arm D1 momentum : 0.500002
    Left Arm D1 NMR : 0.185241
    Left Arm Q3 gauss meter : -0.10096
    Left Arm Q3 power supply current : 199.059
    Left Arm Q3 momentum : 0.499999
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018347
    Right Arm Q2 power supply current : 416.561
    Right Arm Q2 momentum : 0.96792
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967938
    Right Arm D1 NMR : 0.35919
    Right Arm Q3 power supply current : 424.166
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.483152
    Current on Unser monitor : 14.159
    Current on Upstream bcm : 0.483813
    Current on Downstream bcm : 0.482136
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 0.492793
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.397
    Hall A momentum orbit correction (dpp) : -0.00011126
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.398
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.41554
    IPM1C12.XPOS : 0.0560011
    IPM1H04A.XPOS : -0.068382
    IPM1H04A.YPOS : 0.105257
    IPM1H04B.XPOS : -0.179796
    IPM1H04B.YPOS : 0.0511398
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.135254
    HacL_HPE1313A:0_Ch55 : 23.6328
    HacL_HPE1313A:0_Ch54 : -0.152832
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.35652
    SLI vert. size mm : 0
    SLI y position : 1.02911
    -----
    Target : Tantalum
    Vacuum Pressure : 4.73299e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72740
    Target type : -72740
    temperature loop 1(1) : 110.41
    temperature loop 1(3) : 96.65
    Heat exchange He : 92.7
    temperature loop 3(1) : 18.35
    temperature loop 3(3) : 18.57
    Heat exchange H2 : 18.1
    HPH He loop 1 : 0.0970926
    HPH H2 loop 3 : 0.00634721