Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 06:37:00 on February 1, 2008

    Entry number 228518

    keyword=Start_Run_3755,Run_type=Calibration,target_type=Thin Tilted Pb,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,rightarm_p=0.9823,rightarm_theta=25,rightarm_colli=out,comment_text=
    Run Timestamp:       Fri Feb  1 06:36:37 EST 2008
    Beginning-of-run EPICS data for Run Number 3755 at Fri Feb 1 06:36:49 EST 2008
    
    
    
    Run_type=Calibration
    target_type=Thin Tilted Pb
    beam_e0=0.956
    beam_raster=on
    leftarm_p=0.9823
    leftarm_theta=25
    leftarm_colli=out
    rightarm_p=0.9823
    rightarm_theta=25
    rightarm_colli=out
    comment_text=
    
    
    ; HRS Spectrometer DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = S1.and.S2
    ; T2 = HAPPEX S0
    ; T3 = thin HAPPEX detector
    ; T4 = thick HAPPEX detector
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return
    
    ps1=2,ps2=1,ps3=999999,ps4=99999,ps5=99999,ps6=65535,ps7=65535,ps8=65535
    
    
    Left Arm Q1 momentum : 0.982404
    Left Arm Q1 power supply : 739.094
    Left Arm Q1 gauss meter : -0.06231
    Left Arm Q2 power supply current : 423.076
    Left Arm Q2 momentum : 0.982527
    Left Arm Q2 gauss meter : 0.16734
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 326.603
    Left Arm D1 momentum : 0.982377
    Left Arm D1 NMR : 0.36371
    Left Arm Q3 power supply current : 391.192
    Left Arm Q3 momentum : 0.982655
    Left Arm Q3 gauss meter : -0.1984
    Left Arm Q3 power supply polarity : disabled
    Left Arm B Field Hall Probe (D-G) : -0.3511
    Right Arm Q1 momentum : 0.982496
    Right Arm Q1 power supply : 738.773
    Right Arm Q1 gauss meter : -0.018625
    Right Arm Q2 power supply current : 422.821
    Right Arm Q2 momentum : 0.982466
    Right Arm Q2 gauss meter : 0.2216
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 336.022
    Right Arm D1 momentum : 0.982411
    Right Arm D1 NMR : 0.364561
    Right Arm Q3 power supply current : 390.999
    Right Arm Q3 momentum : 0.982635
    Right Arm Q3 gauss meter : 0.17485
    Right Arm Q3 power supply polarity : disabled
    Right Arm B Field Hall Probe (D-G) : -0.3604
    Left Arm Top VDC Current : 1.95312
    Left Arm Bottom VDC Current : -0.683594
    Left Arm Top VDC voltage : 3.99609
    Left Arm Bottom VDC voltage : 4.00244
    Right Arm Top VDC Current : -5.17578
    Right Arm Bottom VDC Current : -1.61133
    Right Arm Top VDC voltage : 3.99707
    Right Arm Bottom VDC voltage : 4
    -----
    Average current of the two cavities : 49.8585
    Current on Unser monitor : 61.9415
    Current on Upstream bcm : 50.0479
    Current on Downstream bcm : 49.669
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 49.5846
    Hall C Current : 0
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.4
    Hall A momentum orbit correction (dpp) : -0.000108862
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.4
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.18227
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 4
    Raster Y width : 5
    Left Arm Collimator : 0.871582
    HacL_HPE1313A:0_Ch58 : -0.149414
    HacL_HPE1313A:0_Ch55 : 23.584
    HacL_HPE1313A:0_Ch54 : -0.184082
    Left Arm Angle Floor Angle : 25
    Left Arm Angle Vernier : 31.2
    Left Arm Scattering Angle : 25.0008
    Right Arm Arm Collimator : 0.863281
    HacR_HPE1313A:0_Ch58 : -0.618652
    HacR_HPE1313A:0_Ch55 : 22.3633
    HacR_HPE1313A:0_Ch54 : -0.907715
    Right Arm Angle Floor Angle : 25
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 24.9999
    -----
    IPM1C12.XPOS : 0.00387341
    IPM1C12.YPOS : -0.010146
    IPM1H04A.XPOS : -2.2722
    IPM1H04A.YPOS : -0.277085
    IPM1H04B.XPOS : -3.51307
    IPM1H04B.YPOS : 0.00332189
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : -46.0068
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 30.613
    Laser attenuation Hall A : 318
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    Target : Thin Pb Slant
    fan frequency loop 1 : 0
    fan frequency loop 2 : 0
    fan frequency loop 3 : 35.5
    Encoder position : 7.97589e+06
    Target type : 7.97589e+06
    temperature loop 1(1) : 104.43
    temperature loop 1(2) : 104.24
    temperature loop 1(3) : 89.51
    Heat exchange He : 87
    temperature loop 3(1) : 18.77
    temperature loop 3(2) : 16.65
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    pressure loop He : 17.1978
    pressure loop H2 before : 21.0529
    pressure loop H2 return : 21.5244
    HPH He loop 1 : 0.0970926
    HPH He loop 2 : 0.0249468
    HPH H2 loop 3 : 90.7759
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.196324
    SLI Energy spread *10^5 : 4.90809
    SLI x position : 1.49068
    SLI vert. size mm : 0.179599
    SLI y position : 1.54742
    CSR NaI 251-270
    CSR Slot13 ch0 : -1001.6
    CSR Slot13 ch1 : -1404.9
    CSR Slot13 ch2 : -1236.7
    CSR Slot13 ch3 : -1403.2
    CSR Slot13 ch4 : -1100.9
    CSR Slot13 ch5 : -1335.4
    CSR Slot13 ch6 : -985.6
    CSR Slot13 ch7 : -1086.7
    CSR Slot13 ch8 : -1086.3
    CSR Slot13 ch9 : -1401.6
    CSR Slot13 ch10 : -1400.7
    CSR Slot13 ch11 : -12.8
    CSR Slot14 ch0 : -1180.8
    CSR Slot14 ch1 : -1380.9
    CSR Slot14 ch2 : -1282.1
    CSR Slot14 ch3 : -1283.6
    CSR Slot14 ch4 : -1160.6
    CSR Slot14 ch5 : -1206.9
    CSR Slot14 ch6 : -1284.3
    CSR Slot14 ch7 : -1283.1
    CSR Slot14 ch8 : -1286.1
    CSR Slot14 ch9 : -1453
    CSR Slot14 ch10 : -821
    CSR Slot14 ch11 : -9.5
    Left S2 HV
    S2 Slot0 ch0 : -2335.9
    S2 Slot0 ch1 : -2202.4
    S2 Slot0 ch2 : -2154.3
    S2 Slot0 ch3 : -2211.9
    S2 Slot0 ch4 : -2425.8
    S2 Slot0 ch5 : -2196.5
    S2 Slot0 ch6 : -1940.7
    S2 Slot0 ch7 : -1867.1
    S2 Slot0 ch8 : -2035.8
    S2 Slot0 ch9 : -1880.5
    S2 Slot0 ch10 : -2060.7
    S2 Slot0 ch11 : -1857.2
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1820.3
    S1 Slot1 ch1 : -1810.5
    S1 Slot1 ch2 : -1805.4
    S1 Slot1 ch3 : -1775.5
    S1 Slot1 ch4 : -1721.8
    S1 Slot1 ch5 : -1900.4
    S1 Slot1 ch6 : -1966.3
    S1 Slot1 ch7 : -1725.9
    S1 Slot1 ch8 : -1951.7
    S1 Slot1 ch9 : -1776.7
    S1 Slot1 ch10 : -1820.1
    S1 Slot1 ch11 : -1860.9
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1570.8
    GCER Slot2 ch1 : -1477.2
    GCER Slot2 ch2 : -1544.8
    GCER Slot2 ch3 : -1460.6
    GCER Slot2 ch4 : -1813.5
    GCER Slot2 ch5 : -1985.9
    GCER Slot2 ch6 : -1690.4
    GCER Slot2 ch7 : -1774.2
    GCER Slot2 ch8 : -2000.7
    GCER Slot2 ch9 : -1635.4
    GCER Slot2 ch10 : -14.2
    GCER Slot2 ch11 : -20.6
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -860.4
    PRL1 Slot3 ch1 : -784.5
    PRL1 Slot3 ch2 : -905.8
    PRL1 Slot3 ch3 : -981.2
    PRL1 Slot3 ch4 : -731.1
    PRL1 Slot3 ch5 : -811
    PRL1 Slot3 ch6 : -1081.3
    PRL1 Slot3 ch7 : -990.8
    PRL1 Slot3 ch8 : -810.5
    PRL1 Slot3 ch9 : -790.9
    PRL1 Slot3 ch10 : -829.5
    PRL1 Slot3 ch11 : -785.3
    PRL1 Slot4 ch0 : -870.8
    PRL1 Slot4 ch1 : -901.3
    PRL1 Slot4 ch2 : -750.8
    PRL1 Slot4 ch3 : -895.1
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -821.2
    PRL1 Slot4 ch6 : -836
    PRL1 Slot4 ch7 : -826.4
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -991.4
    PRL1 Slot4 ch10 : -1031.7
    PRL1 Slot4 ch11 : -861.4
    PRL1 Slot5 ch0 : -1041.1
    PRL1 Slot5 ch1 : -871
    PRL1 Slot5 ch2 : -916.2
    PRL1 Slot5 ch3 : -735.8
    PRL1 Slot5 ch4 : -890.7
    PRL1 Slot5 ch5 : -810.3
    PRL1 Slot5 ch6 : -821.1
    PRL1 Slot5 ch7 : -895.6
    PRL1 Slot5 ch8 : -741.3
    PRL1 Slot5 ch9 : -840.6
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -920.5
    PRL2 Slot9 ch1 : -881.3
    PRL2 Slot9 ch2 : -800.1
    PRL2 Slot9 ch3 : -869.9
    PRL2 Slot9 ch4 : -810.9
    PRL2 Slot9 ch5 : -941.5
    PRL2 Slot9 ch6 : -851.5
    PRL2 Slot9 ch7 : -890.6
    PRL2 Slot9 ch8 : -810.6
    PRL2 Slot9 ch9 : -780.6
    PRL2 Slot9 ch10 : -821
    PRL2 Slot9 ch11 : -851.4
    PRL2 Slot10 ch0 : -755.7
    PRL2 Slot10 ch1 : -812.4
    PRL2 Slot10 ch2 : -871
    PRL2 Slot10 ch3 : -900.8
    PRL2 Slot10 ch4 : -881.4
    PRL2 Slot10 ch5 : -871
    PRL2 Slot10 ch6 : -815.2
    PRL2 Slot10 ch7 : -824.8
    PRL2 Slot10 ch8 : -760.3
    PRL2 Slot10 ch9 : -715.7
    PRL2 Slot10 ch10 : -911
    PRL2 Slot10 ch11 : -781.3
    PRL2 Slot11 ch0 : -1000.7
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -850.6
    PRL2 Slot11 ch3 : -1079.9
    PRL2 Slot11 ch4 : -1050.2
    PRL2 Slot11 ch5 : -800
    PRL2 Slot11 ch6 : -860.4
    PRL2 Slot11 ch7 : -1031.3
    PRL2 Slot11 ch8 : -911.3
    PRL2 Slot11 ch9 : -880.3
    PRL2 Slot11 ch10 : -12.9
    PRL2 Slot11 ch11 : -24.7
    -----