Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 06:37:38 on February 1, 2008
Entry number 228519
keyword=Start_Run_6082,Run_type=Calibration,target_type=Thin Tilted Pb,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=.9823,leftarm_theta=25,leftarm_colli=out,rightarm_p=0.9823,rightarm_theta=25,rightarm_colli=out,comment_text=
Run Timestamp: Fri Feb 1 06:36:34 EST 2008
Beginning-of-run EPICS data for Run Number 6082 at Fri Feb 1 06:36:52 EST 2008
Run_type=Calibration
target_type=Thin Tilted Pb
beam_e0=0.9574
beam_raster=on
beam_halfwaveplate=out
leftarm_p=.9823
leftarm_theta=25
leftarm_colli=out
rightarm_p=0.9823
rightarm_theta=25
rightarm_colli=out
comment_text=
; LEFT SPECTROMETER on adaql5/adev account.
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; Default factor is (2^24)-1 = 16.7M for ps1-4 and (2^16)-1 = 65K for ps5-8.
; T3 = main trigger S1.and.S2
; T4 = efficiency trigger (recommend to keep ~5 Hz)
; T8 = 1024 Hz pulser
; All other prescales should be maxed out.
ps1=9999,ps2=9999,ps3=3,ps4=230,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 momentum : 0.982404
Left Arm Q1 power supply : 739.094
Left Arm Q1 gauss meter : -0.0623
Left Arm Q2 power supply current : 423.076
Left Arm Q2 momentum : 0.982528
Left Arm Q2 gauss meter : 0.16732
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 326.602
Left Arm D1 momentum : 0.982377
Left Arm D1 NMR : 0.36371
Left Arm Q3 power supply current : 391.219
Left Arm Q3 momentum : 0.982602
Left Arm Q3 gauss meter : -0.19838
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.3511
Right Arm Q1 momentum : 0.982496
Right Arm Q1 power supply : 738.72
Right Arm Q1 gauss meter : -0.018621
Right Arm Q2 power supply current : 422.821
Right Arm Q2 momentum : 0.982466
Right Arm Q2 gauss meter : 0.2216
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 336.022
Right Arm D1 momentum : 0.982411
Right Arm D1 NMR : 0.364561
Right Arm Q3 power supply current : 390.999
Right Arm Q3 momentum : 0.982635
Right Arm Q3 gauss meter : 0.17485
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.3604
Left Arm Top VDC Current : -0.0976562
Left Arm Bottom VDC Current : 2.39258
Left Arm Top VDC voltage : 4.00098
Left Arm Bottom VDC voltage : 4.00244
Right Arm Top VDC voltage : 3.99805
Right Arm Bottom VDC voltage : 3.99658
-----
Average current of the two cavities : hac_bcm_average --- Invalid channel name
Current on Unser monitor : hac_unser_current --- Invalid channel name
Current on Upstream bcm : hac_bcm_dvm1_current --- Invalid channel name
Current on Downstream bcm : hac_bcm_dvm2_current --- Invalid channel name
Upstream Cavity Coefficient : hac_bcm_A1 --- Invalid channel name
Downstream Cavity Coefficient : hac_bcm_A2 --- Invalid channel name
Current on IBC0L02 (source) : 49.4535
Hall C Current : 0
Hall A momentum (Tiefenbach) (HALLA:p) : 957.402
Hall A momentum orbit correction (dpp) : -0.000106713
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.402
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.18521
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.87168
HacL_HPE1313A:0_Ch58 : -0.150879
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.185059
Left Arm Angle Floor Angle : 25
Left Arm Angle Vernier : 31.2
Left Arm Scattering Angle : 25.0008
Right Arm Arm Collimator : 0.86333
HacR_HPE1313A:0_Ch58 : -0.618652
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.906738
Right Arm Angle Floor Angle : 25
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 24.9999
-----
IPM1C12.XPOS : -0.00749162
IPM1C12.YPOS : -0.0057411
IPM1H04A.XPOS : -2.26186
IPM1H04A.YPOS : -0.301827
IPM1H04B.XPOS : -3.50351
IPM1H04B.YPOS : -0.0296015
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : -46.0068
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 30.613
Laser attenuation Hall A : 318
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
Target : Thin Pb Slant
Vacuum Pressure : 9.39705e-07
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 36
Encoder position : 7.97589e+06
Target type : 7.97589e+06
temperature loop 1(1) : 104.37
temperature loop 1(2) : 104.21
temperature loop 1(3) : 89.58
Heat exchange He : 87
temperature loop 3(1) : 18.78
temperature loop 3(2) : 16.67
temperature loop 3(3) : 19.01
Heat exchange H2 : 18.5
pressure loop He : 16.5059
pressure loop H2 before : 21.0315
pressure loop H2 return : 21.4939
HPH He loop 1 : 0.0322691
HPH He loop 2 : 0.0333047
HPH H2 loop 3 : 77.6629
SLI data valid? : Yes
SLI horiz size mm : 0.140587
SLI Energy spread *10^5 : 3.51467
SLI x position : 1.49814
SLI vert. size mm : 0.180762
SLI y position : 1.54742
Right S2 HV
S2 Slot1 ch0 : -2275
S2 Slot1 ch1 : -2120.7
S2 Slot1 ch2 : -2275.3
S2 Slot1 ch3 : -2051.3
S2 Slot1 ch4 : -2175.8
S2 Slot1 ch5 : -1990.2
S2 Slot1 ch6 : -2401.6
S2 Slot1 ch7 : -2451.9
S2 Slot1 ch8 : -2251.5
S2 Slot1 ch9 : -2451.1
S2 Slot1 ch10 : -2265.8
S2 Slot1 ch11 : -2001.6
-----
Right S1 HV
S1 Slot2 ch0 : -1720.1
S1 Slot2 ch1 : -1901.6
S1 Slot2 ch2 : -1750.7
S1 Slot2 ch3 : -1746.9
S1 Slot2 ch4 : -1697.7
S1 Slot2 ch5 : -2051.7
S1 Slot2 ch6 : -1811.4
S1 Slot2 ch7 : -1977.4
S1 Slot2 ch8 : -1827
S1 Slot2 ch9 : -1866.7
S1 Slot2 ch10 : -1876.6
S1 Slot2 ch11 : -1947.2
-----
Right Preshower HV
PS Slot4 ch0 : -976.2
PS Slot4 ch1 : -975.6
PS Slot4 ch2 : -975.9
PS Slot4 ch3 : -1001.5
PS Slot4 ch4 : -989
PS Slot4 ch5 : -988.7
PS Slot4 ch6 : -975.4
PS Slot4 ch7 : -960.9
PS Slot4 ch8 : -975.7
PS Slot4 ch9 : -976.3
PS Slot4 ch10 : -977
PS Slot4 ch11 : -975.9
PS Slot5 ch0 : -975.5
PS Slot5 ch1 : -937
PS Slot5 ch2 : -936.7
PS Slot5 ch3 : -975.5
PS Slot5 ch4 : -975.9
PS Slot5 ch5 : -975.3
PS Slot5 ch6 : -976.5
PS Slot5 ch7 : -976.2
PS Slot5 ch8 : -1061.8
PS Slot5 ch9 : -1002.5
PS Slot5 ch10 : -976.2
PS Slot5 ch11 : -975.8
PS Slot7 ch0 : -1098.1
PS Slot7 ch1 : -1008.1
PS Slot7 ch2 : -1001.9
PS Slot7 ch3 : -988.7
PS Slot7 ch4 : -989.5
PS Slot7 ch5 : -989.1
PS Slot7 ch6 : -989.5
PS Slot7 ch7 : -975.4
PS Slot7 ch8 : -975.8
PS Slot7 ch9 : -977.3
PS Slot7 ch10 : -989.4
PS Slot7 ch11 : -989.9
PS Slot8 ch0 : -811.9
PS Slot8 ch1 : -976.4
PS Slot8 ch2 : -975.2
PS Slot8 ch3 : -976
PS Slot8 ch4 : -1126.6
PS Slot8 ch5 : -1002.5
PS Slot8 ch6 : -989.1
PS Slot8 ch7 : -1096.4
PS Slot8 ch8 : -976.5
PS Slot8 ch9 : -1098.4
PS Slot8 ch10 : -975
PS Slot8 ch11 : -974.7
-----
Right Cerenkov HV
GCER Slot14 ch0 : -1502.9
GCER Slot14 ch1 : -3.3
GCER Slot14 ch2 : -15
GCER Slot14 ch3 : -15.8
GCER Slot14 ch4 : -14.3
GCER Slot14 ch5 : -2.5
GCER Slot14 ch6 : -15.8
GCER Slot14 ch7 : -2.6
GCER Slot14 ch8 : -16.6
GCER Slot14 ch9 : -4.1
GCER Slot14 ch10 : -5
GCER Slot14 ch11 : -7.3
-----
Right Shower HV
SH Slot1 ch0 : -698.6
SH Slot1 ch1 : -698.2
SH Slot1 ch2 : -698.7
SH Slot1 ch3 : -700.4
SH Slot1 ch4 : -700.7
SH Slot1 ch5 : -701.8
SH Slot1 ch6 : -699.5
SH Slot1 ch7 : -702
SH Slot1 ch8 : -701.2
SH Slot1 ch9 : -701.4
SH Slot1 ch10 : -701.3
SH Slot1 ch11 : -700.4
SH Slot2 ch0 : -701.5
SH Slot2 ch1 : -700.2
SH Slot2 ch2 : -699.9
SH Slot2 ch3 : -8.6
SH Slot2 ch4 : -701.7
SH Slot2 ch5 : -702.1
SH Slot2 ch6 : -691.1
SH Slot2 ch7 : -635.2
SH Slot2 ch8 : -668.9
SH Slot2 ch9 : -635.9
SH Slot2 ch10 : -635.6
SH Slot2 ch11 : -667.7
SH Slot4 ch0 : -661.2
SH Slot4 ch1 : -659.6
SH Slot4 ch2 : -664
SH Slot4 ch3 : -705.2
SH Slot4 ch4 : -691.7
SH Slot4 ch5 : -667
SH Slot4 ch6 : -827.1
SH Slot4 ch7 : -6.4
SH Slot4 ch8 : -700.9
SH Slot4 ch9 : -685
SH Slot4 ch10 : -688.4
SH Slot4 ch11 : -633.3
SH Slot5 ch0 : -646
SH Slot5 ch1 : -655.6
SH Slot5 ch2 : -594.6
SH Slot5 ch3 : -610.1
SH Slot5 ch4 : -675
SH Slot5 ch5 : -603.5
SH Slot5 ch6 : -656.5
SH Slot5 ch7 : -653.2
SH Slot5 ch8 : -691.6
SH Slot5 ch9 : -679.4
SH Slot5 ch10 : -3.8
SH Slot5 ch11 : -18.4
SH Slot7 ch0 : -759.1
SH Slot7 ch1 : -698.7
SH Slot7 ch2 : -679
SH Slot7 ch3 : -684.5
SH Slot7 ch4 : -672.6
SH Slot7 ch5 : -669.5
SH Slot7 ch6 : -657.4
SH Slot7 ch7 : -651.6
SH Slot7 ch8 : -676.9
SH Slot7 ch9 : -694
SH Slot7 ch10 : -688.2
SH Slot7 ch11 : -704
SH Slot8 ch0 : 1420.4
SH Slot8 ch1 : 1421.6
SH Slot8 ch2 : 1481.6
SH Slot8 ch3 : 1380.8
SH Slot8 ch4 : 1550.4
SH Slot8 ch5 : 1321
SH Slot8 ch6 : 1370.5
SH Slot8 ch7 : 1501.1
SH Slot8 ch8 : 1301.2
SH Slot8 ch9 : 1500.6
SH Slot8 ch10 : 1320.6
SH Slot8 ch11 : 1420.7
SH Slot10 ch0 : 1450.5
SH Slot10 ch1 : 1549.2
SH Slot10 ch2 : 1400.9
SH Slot10 ch3 : 1499.8
SH Slot10 ch4 : 1499.4
SH Slot10 ch5 : 1400.6
SH Slot10 ch6 : 1250.5
SH Slot10 ch7 : 1401.9
SH Slot10 ch8 : 1501.2
SH Slot10 ch9 : 1451.3
SH Slot10 ch10 : 1499.9
SH Slot10 ch11 : 1901.1
-----