Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 19:59:12 on March 29, 2008
Entry number 229017
keyword=End_of_Run_1984
****************************
Run Number: 1984
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=BigBite Scintillator calibration 400K events
PRESCALE FACTORS:ps1=100000 ps2=16777215 ps3=1 ps4=16777215 ps5=100000 ps6=65535 ps7=65535 ps8=65535
EVENTS : [0]: 31886 [+]: 15632 [-]: 15790
TIME : [0]: 40.672 mins [+]: 20.002 mins [-]: 20.003 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 1.64912 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 5.29% [+]: 5.14% [-]: 5.14%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/116.5 Hz T2[0] : 0.0/1168.4 Hz T3[0] :13.8/13.8 Hz T4[0] : 0.0/7.2 Hz T5[0] : 0.0/3.5 Hz T6[0] : 0.0/3.8 Hz T7[0] : 0.0/2.7 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 0.0/116.1 Hz T2[+] : 0.0/1168.1 Hz T3[+] :13.7/13.7 Hz T4[+] : 0.0/7.2 Hz T5[+] : 0.0/3.5 Hz T6[+] : 0.0/3.7 Hz T7[+] : 0.0/2.7 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 0.0/116.8 Hz T2[-] : 0.0/1168.6 Hz T3[-] :13.9/13.9 Hz T4[-] : 0.0/7.2 Hz T5[-] : 0.0/3.5 Hz T6[-] : 0.0/3.8 Hz T7[-] : 0.0/3.8 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 2/284228 T2[0] : 0/2851318 T3[0] : 33629/33629 T4[0] : 0/17628 T5[0] : 0/8572 T6[0] : 0/9155 T7[0] : 0/6694 T8[0] : 38/2498908
T1[+] : 1/139375 T2[+] : 0/1401792 T3[+] : 16461/16461 T4[+] : 0/8653 T5[+] : 0/4202 T6[+] : 0/4453 T7[+] : 0/3291 T8[+] : 18/1228905
T1[-] : 1/140137 T2[-] : 0/1402550 T3[-] : 16626/16626 T4[-] : 0/8681 T5[-] : 0/4222 T6[-] : 0/4557 T7[-] : 0/4557 T8[-] : 18/1228988
AVERAGE CURRENT
BCM x1 : 0.0059 uA BCM x3 : -0.0240uA BCM x10: -0.0007uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-3.252E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.889E+04 ppm
BCM d1 :-1.44E+05 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:2.297E-05 BCM u3 [0]:-0.0001162 BCM u10[0]:3.893E-06
BCM u1 [+]:1.092E-05 BCM u3 [+]:-5.716E-05 BCM u10[+]:1.876E-06
BCM u1 [-]:1.165E-05 BCM u3 [-]:-5.717E-05 BCM u10[-]:1.949E-06
BCM d1 [0]:5.877E-06 BCM d3 [0]:-7.716E-07 BCM d10[0]:-7.115E-06
BCM d1 [+]:2.47E-06 BCM d3 [+]:-4.773E-07 BCM d10[+]:-3.535E-06
BCM d1 [-]:3.302E-06 BCM d3 [-]:-1.771E-07 BCM d10[-]:-3.459E-06
****************************
End-of-run EPICS data for Run Number 1984 at Sat Mar 29 19:58:59 EDT 2008
Wien angle : 0.195965
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.00338697
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.29338
Right Arm arm angle : 0.197
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : -0.732422
Left Arm Bottom VDC Current : 1.46484
-----
Left Arm Q1 momentum : 0.00134401
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.000215
Left Arm Q2 gauss meter : 0.0008316
Left Arm Q2 power supply current : 0.000819891
Left Arm Q2 momentum : 0.00290477
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -1.36496
Left Arm D1 momentum : 0.00343039
Left Arm D1 NMR : 0.156686
Left Arm Q3 gauss meter : -5.78e-05
Left Arm Q3 power supply current : -0.000229454
Left Arm Q3 momentum : -8.97588e-07
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00178685
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -5.37e-05
Right Arm Q2 power supply current : -0.0144161
Right Arm Q2 momentum : -3.2578e-05
Right Arm Q2 gauss meter : 0.0006249
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.316
Right Arm D1 momentum : 0.293353
Right Arm D1 NMR : 7.51913
Right Arm Q3 power supply current : 99.7114
Right Arm Q3 momentum : 0.251875
Right Arm Q3 gauss meter : 0.0447
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0429044
Current on Unser monitor : 11.8639
Current on Upstream bcm : 0.0640448
Current on Downstream bcm : 0.0217641
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00374813
Hall C Current : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5717.78
Delta(E)/E width (MV_AI_DXWID) : -0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.87168
HacL_HPE1313A:0_Ch58 : -0.295898
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : -0.394043
-----
Right Arm Collimator : -0.00224609
HacR_HPE1313A:0_Ch58 : -0.560547
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.858398
-----
Wien angle : 0.195965
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1.75
Wien field : 0
Laser attenuation Hall A : 70
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : -385557
Target type : -385557
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 280.2
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 294.4
HPH He loop 1 : 0.0813417
HPH He loop 2 : 0.00710569
HPH H2 loop 3 : 0.00293052
-----