Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:58:10 on March 30, 2008

    Entry number 229033

    keyword=End_of_Run_1990
    ****************************
     Run Number: 1990
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=BB Scintillators HV set
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 29937        [+]: 14854        [-]: 14643        
    TIME     : [0]: 4.336 mins  [+]: 2.102 mins  [-]: 2.103 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         3.79382 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   6.14%      [+]:   4.63%      [-]:   4.75%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :112.7/112.7 Hz   T2[0] : 0.0/1990.4 Hz   T3[0] :13.5/13.5 Hz   T4[0] : 0.0/7.7  Hz   T5[0] : 3.6/3.6  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.6  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :113.8/113.8 Hz   T2[+] : 0.0/1995.7 Hz   T3[+] :13.3/13.3 Hz   T4[+] : 0.0/7.9  Hz   T5[+] : 3.6/3.6  Hz   T6[+] : 0.0/3.7  Hz   T7[+] : 0.0/2.7  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :111.8/111.8 Hz   T2[-] : 0.0/1984.6 Hz   T3[-] :13.5/13.5 Hz   T4[-] : 0.0/7.6  Hz   T5[-] : 3.5/3.5  Hz   T6[-] : 0.0/3.8  Hz   T7[-] : 0.0/3.8  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  29316/29316    T2[0] :      0/517819   T3[0] :   3505/3505     T4[0] :      0/2013     T5[0] :    925/925      T6[0] :      0/977      T7[0] :      0/668      T8[0] :      4/266402   
    T1[+] :  14354/14354    T2[+] :      0/251727   T3[+] :   1678/1678     T4[+] :      0/1001     T5[+] :    457/457      T6[+] :      0/468      T7[+] :      0/335      T8[+] :      1/129159   
    T1[-] :  14110/14110    T2[-] :      0/250445   T3[-] :   1706/1706     T4[-] :      0/955      T5[-] :    444/444      T6[-] :      0/477      T7[-] :      0/477      T8[-] :      1/129224   
    
    AVERAGE CURRENT
    BCM x1 : 0.0059 uA  BCM x3 : -0.0249uA  BCM x10: -0.0006uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.007E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.678E+04 ppm     
    BCM d1 :-9.488E+04 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.441E-06      BCM u3 [0]:-1.24E-05      BCM u10[0]:4.597E-07      
    BCM u1 [+]:1.159E-06      BCM u3 [+]:-6.01E-06      BCM u10[+]:2.195E-07      
    BCM u1 [-]:1.232E-06      BCM u3 [-]:-6.017E-06     BCM u10[-]:2.271E-07      
    
    BCM d1 [0]:6.329E-07      BCM d3 [0]:-5.531E-07     BCM d10[0]:-7.536E-07     
    BCM d1 [+]:2.72E-07       BCM d3 [+]:-2.863E-07     BCM d10[+]:-3.7E-07       
    BCM d1 [-]:3.291E-07      BCM d3 [-]:-2.506E-07     BCM d10[-]:-3.606E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1990 at Sun Mar 30 09:57:55 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.003429
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.293871
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : -0.878906
    Left Arm Bottom VDC Current : 4.29688
    -----
    Left Arm Q1 momentum : 0.00143007
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002089
    Left Arm Q2 gauss meter : 0.0008436
    Left Arm Q2 power supply current : -0.000535363
    Left Arm Q2 momentum : -8.25966e-07
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.36395
    Left Arm D1 momentum : 0.00339281
    Left Arm D1 NMR : 0.156665
    Left Arm Q3 gauss meter : -5.04e-05
    Left Arm Q3 power supply current : -0.000297162
    Left Arm Q3 momentum : -2.04083e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00180806
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -5.41e-05
    Right Arm Q2 power supply current : -0.0159838
    Right Arm Q2 momentum : -3.63754e-05
    Right Arm Q2 gauss meter : 0.0006219
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.317
    Right Arm D1 momentum : 0.293898
    Right Arm D1 NMR : 7.51828
    Right Arm Q3 power supply current : 99.7115
    Right Arm Q3 momentum : 0.251875
    Right Arm Q3 gauss meter : 0.0447
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0422925
    Current on Unser monitor : 10.9169
    Current on Upstream bcm : 0.0632596
    Current on Downstream bcm : 0.0212569
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 3.07089
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 4.13778
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.29541
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.393066
    -----
    Right Arm Collimator : -0.00249023
    HacR_HPE1313A:0_Ch58 : -0.561035
    HacR_HPE1313A:0_Ch55 : 22.2168
    HacR_HPE1313A:0_Ch54 : -0.860352
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.4
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.1
    HPH He loop 1 : 0.0970926
    HPH He loop 2 : 0.0118473
    HPH H2 loop 3 : 0.00634721
    -----