    keyword=End_of_Run_1991
    ****************************
     Run Number: 1991
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=BB Scintillators HV set
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 420273       [+]: 207373       [-]: 206779       
    TIME     : [0]: 59.401 mins  [+]: 29.228 mins  [-]: 29.229 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         0.52206 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   3.72%      [+]:   3.55%      [-]:   3.66%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :112.4/112.4 Hz   T2[0] : 0.0/1987.4 Hz   T3[0] :13.5/13.5 Hz   T4[0] : 0.0/7.4  Hz   T5[0] : 3.4/3.4  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.6  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :112.6/112.6 Hz   T2[+] : 0.0/1988.0 Hz   T3[+] :13.5/13.5 Hz   T4[+] : 0.0/7.3  Hz   T5[+] : 3.5/3.5  Hz   T6[+] : 0.0/3.8  Hz   T7[+] : 0.0/2.6  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :112.2/112.2 Hz   T2[-] : 0.0/1986.6 Hz   T3[-] :13.5/13.5 Hz   T4[-] : 0.0/7.5  Hz   T5[-] : 3.4/3.4  Hz   T6[-] : 0.0/3.7  Hz   T7[-] : 0.0/3.7  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 400547/400547   T2[0] :      0/7083032  T3[0] :  48192/48192    T4[0] :      0/26352    T5[0] :  12251/12251    T6[0] :      0/13374    T7[0] :      0/9247     T8[0] :     55/3649593  
    T1[+] : 197401/197401   T2[+] :      0/3486308  T3[+] :  23702/23702    T4[+] :      0/12888    T5[+] :   6103/6103     T6[+] :      0/6590     T7[+] :      0/4598     T8[+] :     27/1795770  
    T1[-] : 196826/196826   T2[-] :      0/3483966  T3[-] :  23750/23750    T4[-] :      0/13071    T5[-] :   5951/5951     T6[-] :      0/6574     T7[-] :      0/6574     T8[-] :     27/1795823  
    
    AVERAGE CURRENT
    BCM x1 : 0.0059 uA  BCM x3 : -0.0249uA  BCM x10: -0.0007uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.274E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.922E+04 ppm     
    BCM d1 :-1.515E+05 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:3.35E-05       BCM u3 [0]:-0.0001698     BCM u10[0]:5.783E-06      
    BCM u1 [+]:1.595E-05      BCM u3 [+]:-8.356E-05     BCM u10[+]:2.79E-06       
    BCM u1 [-]:1.703E-05      BCM u3 [-]:-8.358E-05     BCM u10[-]:2.899E-06      
    
    BCM d1 [0]:8.65E-06       BCM d3 [0]:-7.763E-06     BCM d10[0]:-1.053E-05     
    BCM d1 [+]:3.61E-06       BCM d3 [+]:-3.984E-06     BCM d10[+]:-5.234E-06     
    BCM d1 [-]:4.898E-06      BCM d3 [-]:-3.644E-06     BCM d10[-]:-5.132E-06     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1991 at Sun Mar 30 11:00:13 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00343039
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.293871
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 5.27344
    Heat exchange H2 : 295.1
    Left Arm Bottom VDC Current : -1.61133
    -----
    HPH He loop 1 : 0.0813417
    Left Arm Q1 momentum : 0.0013315
    HPH He loop 2 : 0.00356948
    Left Arm Q1 power supply : 0
    HPH H2 loop 3 : 0.011068
    -----