Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 11:00:28 on March 30, 2008
Entry number 229037
keyword=End_of_Run_1991
****************************
Run Number: 1991
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=BB Scintillators HV set
PRESCALE FACTORS:ps1=1 ps2=16777215 ps3=1 ps4=16777215 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS : [0]: 420273 [+]: 207373 [-]: 206779
TIME : [0]: 59.401 mins [+]: 29.228 mins [-]: 29.229 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 0.52206 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 3.72% [+]: 3.55% [-]: 3.66%
TRIGGER RATES: PRES/REAL
T1[0] :112.4/112.4 Hz T2[0] : 0.0/1987.4 Hz T3[0] :13.5/13.5 Hz T4[0] : 0.0/7.4 Hz T5[0] : 3.4/3.4 Hz T6[0] : 0.0/3.8 Hz T7[0] : 0.0/2.6 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :112.6/112.6 Hz T2[+] : 0.0/1988.0 Hz T3[+] :13.5/13.5 Hz T4[+] : 0.0/7.3 Hz T5[+] : 3.5/3.5 Hz T6[+] : 0.0/3.8 Hz T7[+] : 0.0/2.6 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :112.2/112.2 Hz T2[-] : 0.0/1986.6 Hz T3[-] :13.5/13.5 Hz T4[-] : 0.0/7.5 Hz T5[-] : 3.4/3.4 Hz T6[-] : 0.0/3.7 Hz T7[-] : 0.0/3.7 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 400547/400547 T2[0] : 0/7083032 T3[0] : 48192/48192 T4[0] : 0/26352 T5[0] : 12251/12251 T6[0] : 0/13374 T7[0] : 0/9247 T8[0] : 55/3649593
T1[+] : 197401/197401 T2[+] : 0/3486308 T3[+] : 23702/23702 T4[+] : 0/12888 T5[+] : 6103/6103 T6[+] : 0/6590 T7[+] : 0/4598 T8[+] : 27/1795770
T1[-] : 196826/196826 T2[-] : 0/3483966 T3[-] : 23750/23750 T4[-] : 0/13071 T5[-] : 5951/5951 T6[-] : 0/6574 T7[-] : 0/6574 T8[-] : 27/1795823
AVERAGE CURRENT
BCM x1 : 0.0059 uA BCM x3 : -0.0249uA BCM x10: -0.0007uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-3.274E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.922E+04 ppm
BCM d1 :-1.515E+05 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:3.35E-05 BCM u3 [0]:-0.0001698 BCM u10[0]:5.783E-06
BCM u1 [+]:1.595E-05 BCM u3 [+]:-8.356E-05 BCM u10[+]:2.79E-06
BCM u1 [-]:1.703E-05 BCM u3 [-]:-8.358E-05 BCM u10[-]:2.899E-06
BCM d1 [0]:8.65E-06 BCM d3 [0]:-7.763E-06 BCM d10[0]:-1.053E-05
BCM d1 [+]:3.61E-06 BCM d3 [+]:-3.984E-06 BCM d10[+]:-5.234E-06
BCM d1 [-]:4.898E-06 BCM d3 [-]:-3.644E-06 BCM d10[-]:-5.132E-06
****************************
End-of-run EPICS data for Run Number 1991 at Sun Mar 30 11:00:13 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.00343039
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.293871
Right Arm arm angle : 0.197
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : 5.27344
Heat exchange H2 : 295.1
Left Arm Bottom VDC Current : -1.61133
-----
HPH He loop 1 : 0.0813417
Left Arm Q1 momentum : 0.0013315
HPH He loop 2 : 0.00356948
Left Arm Q1 power supply : 0
HPH H2 loop 3 : 0.011068
-----
Left Arm Q1 gauss meter : 0.0002239
Left Arm Q2 gauss meter : 0.0007959
Left Arm Q2 power supply current : -0.000299504
Left Arm Q2 momentum : -6.9555e-07
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -1.36704
Left Arm D1 momentum : 0.00339253
Left Arm D1 NMR : 0.156657
Left Arm Q3 gauss meter : -5.09e-05
Left Arm Q3 power supply current : -0.000545424
Left Arm Q3 momentum : -4.15725e-07
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.000837752
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -3.58e-05
Right Arm Q2 power supply current : -0.0157731
Right Arm Q2 momentum : -3.66503e-05
Right Arm Q2 gauss meter : 0.0006241
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.318
Right Arm D1 momentum : 0.293871
Right Arm D1 NMR : 7.51812
Right Arm Q3 power supply current : 99.7114
Right Arm Q3 momentum : 0.251875
Right Arm Q3 gauss meter : 0.0447
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.042479
Current on Unser monitor : 11.7318
Current on Upstream bcm : 0.0636074
Current on Downstream bcm : 0.0213507
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00325585
Hall C Current : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5717.78
Delta(E)/E width (MV_AI_DXWID) : 4.2541
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.87168
HacL_HPE1313A:0_Ch58 : -0.294434
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.393066
-----
Right Arm Collimator : -0.00239258
HacR_HPE1313A:0_Ch58 : -0.561035
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.860352
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : -385557
Target type : -385557
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 281.4
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.1
HPH He loop 1 : 0.0970926
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.00634721
-----