    Log entry time 17:06:36 on March 30, 2008

    Entry number 229060

    keyword=End_of_Run_2003
    ****************************
     Run Number: 2003
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=BB scintillator high voltage change
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 100345       [+]: 49552        [-]: 49318        
    TIME     : [0]: 16.058 mins  [+]: 7.944 mins  [-]: 7.943 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -5.03411 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   2.92%      [+]:   3.39%      [-]:   3.24%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :97.1/97.1 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :13.7/13.7 Hz   T4[0] : 0.0/7.3  Hz   T5[0] : 3.5/3.5  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/2.7  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :97.2/97.2 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :13.9/13.9 Hz   T4[+] : 0.0/7.4  Hz   T5[+] : 3.5/3.5  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/2.7  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :97.1/97.1 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :13.4/13.4 Hz   T4[-] : 0.0/7.3  Hz   T5[-] : 3.5/3.5  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  93578/93578    T2[0] :      0/0        T3[0] :  13158/13158    T4[0] :      0/7060     T5[0] :   3378/3378     T6[0] :      0/0        T7[0] :      0/2572     T8[0] :     15/986583   
    T1[+] :  46313/46313    T2[+] :      0/0        T3[+] :   6643/6643     T4[+] :      0/3538     T5[+] :   1668/1668     T6[+] :      0/0        T7[+] :      0/1286     T8[+] :      7/488081   
    T1[-] :  46259/46259    T2[-] :      0/0        T3[-] :   6385/6385     T4[-] :      0/3472     T5[-] :   1678/1678     T6[-] :      0/0        T7[-] :      0/0        T8[-] :      7/488039   
    
    AVERAGE CURRENT
    BCM x1 : 0.0059 uA  BCM x3 : -0.0205uA  BCM x10: -0.0005uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.366E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.648E+04 ppm     
    BCM d1 :-1.593E+05 ppm     BCM d3 :-3.71E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:9.042E-06      BCM u3 [0]:-4.59E-05      BCM u10[0]:1.711E-06      
    BCM u1 [+]:4.362E-06      BCM u3 [+]:-2.271E-05     BCM u10[+]:8.315E-07      
    BCM u1 [-]:4.665E-06      BCM u3 [-]:-2.271E-05     BCM u10[-]:8.593E-07      
    
    BCM d1 [0]:2.314E-06      BCM d3 [0]:6.373E-06      BCM d10[0]:-2.736E-06     
    BCM d1 [+]:9.62E-07       BCM d3 [+]:3.234E-06      BCM d10[+]:-1.37E-06      
    BCM d1 [-]:1.326E-06      BCM d3 [-]:3.483E-06      BCM d10[-]:-1.337E-06     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2003 at Sun Mar 30 17:06:26 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00341258
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.293898
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 1.70898
    Left Arm Bottom VDC Current : -1.17188
    -----
    Left Arm Q1 momentum : 0.00129551
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002262
    Left Arm Q2 gauss meter : 0.0007944
    Left Arm Q2 power supply current : -0.000816148
    Left Arm Q2 momentum : -1.18243e-06
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.3725
    Left Arm D1 momentum : 0.00345266
    Left Arm D1 NMR : 0.156671
    Left Arm Q3 gauss meter : -7.46e-05
    Left Arm Q3 power supply current : -0.000466431
    Left Arm Q3 momentum : -1.17159e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00206787
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -4.24e-05
    Right Arm Q2 power supply current : -0.0143089
    Right Arm Q2 momentum : -3.37378e-05
    Right Arm Q2 gauss meter : 0.0006228
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.317
    Right Arm D1 momentum : 0.293925
    Right Arm D1 NMR : 7.51909
    Right Arm Q3 power supply current : -0.00010088
    Right Arm Q3 momentum : -2.98597e-06
    Right Arm Q3 gauss meter : 0.0001536
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0426851
    Current on Unser monitor : 12.1646
    Current on Upstream bcm : 0.064134
    Current on Downstream bcm : 0.0215556
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.868489
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 2.33301
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.294922
    HacL_HPE1313A:0_Ch55 : 23.3887
    HacL_HPE1313A:0_Ch54 : -0.393066
    -----
    Right Arm Collimator : -0.00283203
    HacR_HPE1313A:0_Ch58 : -0.558594
    HacR_HPE1313A:0_Ch55 : 22.2656
    HacR_HPE1313A:0_Ch54 : -0.861816
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.7
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.3
    HPH He loop 1 : 0.0970926
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00634721
    -----