Log entry time 17:27:56 on March 30, 2008
Entry number 229062
keyword=End_of_Run_2004
****************************
Run Number: 2004
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=BB scintillator high voltage change
PRESCALE FACTORS:ps1=1 ps2=16777215 ps3=1 ps4=16777215 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS : [0]: 130178 [+]: 64104 [-]: 64196
TIME : [0]: 20.760 mins [+]: 10.262 mins [-]: 10.260 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -5.36370 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 2.98% [+]: 3.44% [-]: 3.15%
TRIGGER RATES: PRES/REAL
T1[0] :97.7/97.7 Hz T2[0] : 0.0/0.0 Hz T3[0] :13.4/13.4 Hz T4[0] : 0.0/7.4 Hz T5[0] : 3.4/3.4 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/2.7 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :97.5/97.5 Hz T2[+] : 0.0/0.0 Hz T3[+] :13.7/13.7 Hz T4[+] : 0.0/7.2 Hz T5[+] : 3.5/3.5 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/2.7 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :97.8/97.8 Hz T2[-] : 0.0/0.0 Hz T3[-] :13.2/13.2 Hz T4[-] : 0.0/7.6 Hz T5[-] : 3.3/3.3 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 121662/121662 T2[0] : 0/0 T3[0] : 16748/16748 T4[0] : 0/9209 T5[0] : 4240/4240 T6[0] : 0/0 T7[0] : 0/3303 T8[0] : 19/1275519
T1[+] : 60061/60061 T2[+] : 0/0 T3[+] : 8453/8453 T4[+] : 0/4439 T5[+] : 2127/2127 T6[+] : 0/0 T7[+] : 0/1669 T8[+] : 9/630472
T1[-] : 60201/60201 T2[-] : 0/0 T3[-] : 8137/8137 T4[-] : 0/4657 T5[-] : 2056/2056 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 9/630366
AVERAGE CURRENT
BCM x1 : 0.0059 uA BCM x3 : -0.0203uA BCM x10: -0.0004uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-3.682E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.608E+04 ppm
BCM d1 :-1.187E+05 ppm BCM d3 :-3.504E+04 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:1.166E-05 BCM u3 [0]:-5.935E-05 BCM u10[0]:2.425E-06
BCM u1 [+]:5.491E-06 BCM u3 [+]:-2.933E-05 BCM u10[+]:1.179E-06
BCM u1 [-]:5.91E-06 BCM u3 [-]:-2.933E-05 BCM u10[-]:1.217E-06
BCM d1 [0]:3.065E-06 BCM d3 [0]:8.679E-06 BCM d10[0]:-3.49E-06
BCM d1 [+]:1.331E-06 BCM d3 [+]:4.384E-06 BCM d10[+]:-1.741E-06
BCM d1 [-]:1.689E-06 BCM d3 [-]:4.701E-06 BCM d10[-]:-1.707E-06
****************************
End-of-run EPICS data for Run Number 2004 at Sun Mar 30 17:27:44 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.00341731
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.29398
Right Arm arm angle : 0.197
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : 2.88086
Left Arm Bottom VDC Current : 1.46484
-----
Left Arm Q1 momentum : 0.00129864
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.000226
Left Arm Q2 gauss meter : 0.0008022
Left Arm Q2 power supply current : -0.000243347
Left Arm Q2 momentum : -5.65134e-07
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -1.36698
Left Arm D1 momentum : 0.00339142
Left Arm D1 NMR : 0.156658
Left Arm Q3 gauss meter : -7.71e-05
Left Arm Q3 power supply current : -0.00085387
Left Arm Q3 momentum : -2.14476e-06
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00130965
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -4.47e-05
Right Arm Q2 power supply current : -0.0156622
Right Arm Q2 momentum : -3.75781e-05
Right Arm Q2 gauss meter : 0.0006349
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.317
Right Arm D1 momentum : 0.29398
Right Arm D1 NMR : 7.5187
Right Arm Q3 power supply current : -0.00198024
Right Arm Q3 momentum : -2.99536e-06
Right Arm Q3 gauss meter : 0.0001537
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0425266
Current on Unser monitor : 11.9554
Current on Upstream bcm : 0.0636621
Current on Downstream bcm : 0.0213911
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.865993
Hall C Current : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5717.78
Delta(E)/E width (MV_AI_DXWID) : 2.33039
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.294922
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.393555
-----
Right Arm Collimator : -0.00742188
HacR_HPE1313A:0_Ch58 : -0.558594
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.862305
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : -385557
Target type : -385557
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 281.7
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.3
HPH He loop 1 : 0.0540192
HPH He loop 2 : 0.00710569
HPH H2 loop 3 : 0.00634721
-----