Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:46:46 on March 30, 2008

    Entry number 229080

    keyword=End_of_Run_2012
    ****************************
     Run Number: 2012
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=chamber test
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 32988        [+]: 16268        [-]: 16265        
    TIME     : [0]: 5.756 mins  [+]: 2.869 mins  [-]: 2.869 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.47670 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  11.20%      [+]:  12.29%      [-]:  12.18%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :97.5/97.5 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :13.6/13.6 Hz   T4[0] : 0.0/7.3  Hz   T5[0] : 3.6/3.6  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :97.6/97.6 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :13.6/13.6 Hz   T4[+] : 0.0/7.4  Hz   T5[+] : 3.4/3.4  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :97.7/97.7 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :13.6/13.6 Hz   T4[-] : 0.0/7.4  Hz   T5[-] : 3.7/3.7  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  33672/33672    T2[0] :      0/0        T3[0] :   4703/4703     T4[0] :      0/2537     T5[0] :   1226/1226     T6[0] :      0/0        T7[0] :      0/0        T8[0] :      5/353628   
    T1[+] :  16793/16793    T2[+] :      0/0        T3[+] :   2339/2339     T4[+] :      0/1268     T5[+] :    585/585      T6[+] :      0/0        T7[+] :      0/0        T8[+] :      2/176279   
    T1[-] :  16816/16816    T2[-] :      0/0        T3[-] :   2343/2343     T4[-] :      0/1269     T5[-] :    639/639      T6[-] :      0/0        T7[-] :      0/0        T8[-] :      2/176292   
    
    AVERAGE CURRENT
    BCM x1 : 0.0057 uA  BCM x3 : -0.0209uA  BCM x10: -0.0011uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.753E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-4.932E+04 ppm     
    BCM d1 :-1.391E+05 ppm     BCM d3 :-1.443E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:3.017E-06      BCM u3 [0]:-1.658E-05     BCM u10[0]:2.648E-07      
    BCM u1 [+]:1.438E-06      BCM u3 [+]:-8.265E-06     BCM u10[+]:1.267E-07      
    BCM u1 [-]:1.551E-06      BCM u3 [-]:-8.265E-06     BCM u10[-]:1.399E-07      
    
    BCM d1 [0]:8.93E-07       BCM d3 [0]:2.176E-06      BCM d10[0]:-1.052E-06     
    BCM d1 [+]:3.823E-07      BCM d3 [+]:1.112E-06      BCM d10[+]:-5.312E-07     
    BCM d1 [-]:5.059E-07      BCM d3 [-]:1.144E-06      BCM d10[-]:-5.189E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2012 at Sun Mar 30 20:46:33 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00339448
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.294007
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 3.95508
    Left Arm Bottom VDC Current : -0.341797
    -----
    Left Arm Q1 momentum : 0.00144102
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002317
    Left Arm Q2 gauss meter : 0.0007831
    Left Arm Q2 power supply current : 0.0106623
    Left Arm Q2 momentum : 0.00282208
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.35916
    Left Arm D1 momentum : 0.0034368
    Left Arm D1 NMR : 0.156685
    Left Arm Q3 gauss meter : -8.32e-05
    Left Arm Q3 power supply current : -0.000504047
    Left Arm Q3 momentum : -1.20938e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.000445387
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -3.68e-05
    Right Arm Q2 power supply current : -0.0142387
    Right Arm Q2 momentum : -3.30849e-05
    Right Arm Q2 gauss meter : 0.0006193
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.316
    Right Arm D1 momentum : 0.294034
    Right Arm D1 NMR : 7.51936
    Right Arm Q3 power supply current : -0.00140485
    Right Arm Q3 momentum : -3.53058e-06
    Right Arm Q3 gauss meter : 0.0001528
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0422628
    Current on Unser monitor : 11.5174
    Current on Upstream bcm : 0.0632506
    Current on Downstream bcm : 0.021275
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00293572
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.56415
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.296387
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.392578
    -----
    Right Arm Collimator : -0.00273438
    HacR_HPE1313A:0_Ch58 : -0.560547
    HacR_HPE1313A:0_Ch55 : 22.1191
    HacR_HPE1313A:0_Ch54 : -0.862305
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.8
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.0170928
    -----