Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:48:18 on March 30, 2008

    Entry number 229082

    keyword=End_of_Run_2013
    ****************************
     Run Number: 2013
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=chamber test
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 5778         [+]: 2796         [-]: 2904         
    TIME     : [0]: 1.043 mins  [+]: 0.548 mins  [-]: 0.548 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.19505 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  11.28%      [+]:  16.02%      [-]:  17.29%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :94.2/94.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :13.6/13.6 Hz   T4[0] : 0.0/7.4  Hz   T5[0] : 3.8/3.8  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :92.4/92.4 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :12.9/12.9 Hz   T4[+] : 0.0/7.6  Hz   T5[+] : 4.0/4.0  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :96.4/96.4 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :14.0/14.0 Hz   T4[-] : 0.0/6.8  Hz   T5[-] : 3.6/3.6  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   5896/5896     T2[0] :      0/0        T3[0] :    853/853      T4[0] :      0/466      T5[0] :    237/237      T6[0] :      0/0        T7[0] :      0/0        T8[0] :      0/64077    
    T1[+] :   3035/3035     T2[+] :      0/0        T3[+] :    425/425      T4[+] :      0/251      T5[+] :    131/131      T6[+] :      0/0        T7[+] :      0/0        T8[+] :      0/33644    
    T1[-] :   3169/3169     T2[-] :      0/0        T3[-] :    460/460      T4[-] :      0/222      T5[-] :    118/118      T6[-] :      0/0        T7[-] :      0/0        T8[-] :      0/33652    
    
    AVERAGE CURRENT
    BCM x1 : 0.0059 uA  BCM x3 : -0.0211uA  BCM x10: -0.0009uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.792E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.536E+04 ppm     
    BCM d1 :-1.932E+05 ppm     BCM d3 :   -919.3 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:5.697E-07      BCM u3 [0]:-3.004E-06     BCM u10[0]:7.147E-08      
    BCM u1 [+]:2.887E-07      BCM u3 [+]:-1.577E-06     BCM u10[+]:3.68E-08       
    BCM u1 [-]:3.115E-07      BCM u3 [-]:-1.578E-06     BCM u10[-]:3.796E-08      
    
    BCM d1 [0]:1.692E-07      BCM d3 [0]:3.595E-07      BCM d10[0]:-1.846E-07     
    BCM d1 [+]:7.284E-08      BCM d3 [+]:1.926E-07      BCM d10[+]:-9.772E-08     
    BCM d1 [-]:1.077E-07      BCM d3 [-]:1.93E-07       BCM d10[-]:-9.586E-08     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2013 at Sun Mar 30 20:48:10 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00341258
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.294007
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 3.4668
    Left Arm Bottom VDC Current : 3.85742
    -----
    Left Arm Q1 momentum : 0.0015083
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002126
    Left Arm Q2 gauss meter : 0.0008418
    Left Arm Q2 power supply current : 0.0102805
    Left Arm Q2 momentum : 0.00303409
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.36092
    Left Arm D1 momentum : 0.00339643
    Left Arm D1 NMR : 0.156686
    Left Arm Q3 gauss meter : -8.33e-05
    Left Arm Q3 power supply current : -0.000680839
    Left Arm Q3 momentum : -1.096e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00170201
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -5.21e-05
    Right Arm Q2 power supply current : -0.0145862
    Right Arm Q2 momentum : -3.38925e-05
    Right Arm Q2 gauss meter : 0.0006279
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.315
    Right Arm D1 momentum : 0.294007
    Right Arm D1 NMR : 7.51937
    Right Arm Q3 power supply current : -0.000328795
    Right Arm Q3 momentum : -8.26307e-07
    Right Arm Q3 gauss meter : 0.0001526
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0423614
    Current on Unser monitor : 11.6084
    Current on Upstream bcm : 0.0634471
    Current on Downstream bcm : 0.0212756
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00306489
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.56358
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.296387
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.391602
    -----
    Right Arm Collimator : -0.00258789
    HacR_HPE1313A:0_Ch58 : -0.55957
    HacR_HPE1313A:0_Ch55 : 22.1191
    HacR_HPE1313A:0_Ch54 : -0.861816
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.8
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.011068
    -----