Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:52:13 on March 30, 2008

    Entry number 229084

    keyword=End_of_Run_2014
    ****************************
     Run Number: 2014
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=chamber test
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 3998         [+]: 1967         [-]: 1966         
    TIME     : [0]: 0.683 mins  [+]: 0.369 mins  [-]: 0.370 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.10351 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  10.54%      [+]:  17.43%      [-]:  19.53%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :99.9/99.9 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :12.6/12.6 Hz   T4[0] : 0.0/7.7  Hz   T5[0] : 3.4/3.4  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :98.6/98.6 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :12.2/12.2 Hz   T4[+] : 0.0/6.8  Hz   T5[+] : 3.3/3.3  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :100.0/100.0 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :13.1/13.1 Hz   T4[-] : 0.0/8.4  Hz   T5[-] : 3.1/3.1  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   4093/4093     T2[0] :      0/0        T3[0] :    517/517      T4[0] :      0/317      T5[0] :    141/141      T6[0] :      0/0        T7[0] :      0/0        T8[0] :      0/41962    
    T1[+] :   2186/2186     T2[+] :      0/0        T3[+] :    270/270      T4[+] :      0/151      T5[+] :     74/74       T6[+] :      0/0        T7[+] :      0/0        T8[+] :      0/22693    
    T1[-] :   2222/2222     T2[-] :      0/0        T3[-] :    290/290      T4[-] :      0/187      T5[-] :     69/69       T6[-] :      0/0        T7[-] :      0/0        T8[-] :      0/22744    
    
    AVERAGE CURRENT
    BCM x1 : 0.0061 uA  BCM x3 : -0.0191uA  BCM x10: -0.0007uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.272E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:     5856 ppm     
    BCM d1 :-1.755E+05 ppm     BCM d3 :-2.025E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:3.862E-07      BCM u3 [0]:-1.967E-06     BCM u10[0]:6.19E-08       
    BCM u1 [+]:2.043E-07      BCM u3 [+]:-1.064E-06     BCM u10[+]:3.387E-08      
    BCM u1 [-]:2.186E-07      BCM u3 [-]:-1.066E-06     BCM u10[-]:3.355E-08      
    
    BCM d1 [0]:1.122E-07      BCM d3 [0]:3.997E-07      BCM d10[0]:-1.172E-07     
    BCM d1 [+]:4.901E-08      BCM d3 [+]:2.153E-07      BCM d10[+]:-6.404E-08     
    BCM d1 [-]:7.003E-08      BCM d3 [-]:2.247E-07      BCM d10[-]:-6.314E-08     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2014 at Sun Mar 30 20:52:00 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00339476
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.29398
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : -2.19727
    Left Arm Bottom VDC Current : 4.05273
    -----
    Left Arm Q1 momentum : 0.0014285
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002175
    Left Arm Q2 gauss meter : 0.0008414
    Left Arm Q2 power supply current : 0.0106811
    Left Arm Q2 momentum : 0.00308555
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.36536
    Left Arm D1 momentum : 0.00339476
    Left Arm D1 NMR : 0.156686
    Left Arm Q3 gauss meter : -7.42e-05
    Left Arm Q3 power supply current : -0.000515332
    Left Arm Q3 momentum : -1.37e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00154295
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -3.36e-05
    Right Arm Q2 power supply current : -0.0151002
    Right Arm Q2 momentum : -3.50867e-05
    Right Arm Q2 gauss meter : 0.0006265
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.316
    Right Arm D1 momentum : 0.294007
    Right Arm D1 NMR : 7.51937
    Right Arm Q3 power supply current : -0.000836932
    Right Arm Q3 momentum : -2.10333e-06
    Right Arm Q3 gauss meter : 0.0001524
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0424922
    Current on Unser monitor : 12.1809
    Current on Upstream bcm : 0.063497
    Current on Downstream bcm : 0.0213941
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00276958
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.55895
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.295898
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.38916
    -----
    Right Arm Collimator : -0.00595703
    HacR_HPE1313A:0_Ch58 : -0.560059
    HacR_HPE1313A:0_Ch55 : 22.168
    HacR_HPE1313A:0_Ch54 : -0.862305
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.8
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00356948
    HPH H2 loop 3 : 0.00634721
    -----