Log entry time 21:26:01 on March 30, 2008
Entry number 229096
keyword=End_of_Run_2019
****************************
Run Number: 2019
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=chamber test
PRESCALE FACTORS:ps1=1 ps2=16777215 ps3=1 ps4=16777215 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS : [0]: 8961 [+]: 4359 [-]: 4457
TIME : [0]: 1.420 mins [+]: 0.733 mins [-]: 0.732 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.12998 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 2.77% [+]: 6.96% [-]: 7.13%
TRIGGER RATES: PRES/REAL
T1[0] :98.7/98.7 Hz T2[0] : 0.0/1497.0 Hz T3[0] :13.3/13.3 Hz T4[0] : 0.0/7.8 Hz T5[0] : 3.8/3.8 Hz T6[0] : 0.0/3.7 Hz T7[0] : 0.0/2.5 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :96.7/96.7 Hz T2[+] : 0.0/1498.1 Hz T3[+] :13.5/13.5 Hz T4[+] : 0.0/7.9 Hz T5[+] : 3.7/3.7 Hz T6[+] : 0.0/3.7 Hz T7[+] : 0.0/2.4 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :100.0/100.0 Hz T2[-] : 0.0/1496.1 Hz T3[-] :12.9/12.9 Hz T4[-] : 0.0/7.9 Hz T5[-] : 3.6/3.6 Hz T6[-] : 0.0/3.8 Hz T7[-] : 0.0/3.8 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 8404/8404 T2[0] : 0/127505 T3[0] : 1132/1132 T4[0] : 0/668 T5[0] : 320/320 T6[0] : 0/318 T7[0] : 0/210 T8[0] : 1/87217
T1[+] : 4253/4253 T2[+] : 0/65885 T3[+] : 594/594 T4[+] : 0/347 T5[+] : 162/162 T6[+] : 0/164 T7[+] : 0/105 T8[+] : 0/45034
T1[-] : 4390/4390 T2[-] : 0/65704 T3[-] : 568/568 T4[-] : 0/347 T5[-] : 159/159 T6[-] : 0/165 T7[-] : 0/165 T8[-] : 0/44972
AVERAGE CURRENT
BCM x1 : 0.0064 uA BCM x3 : -0.0192uA BCM x10: -0.0003uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-3.315E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-2.133E+04 ppm
BCM d1 :-2.284E+05 ppm BCM d3 :-1.653E+04 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:8.345E-07 BCM u3 [0]:-4.06E-06 BCM u10[0]:1.743E-07
BCM u1 [+]:4.206E-07 BCM u3 [+]:-2.097E-06 BCM u10[+]:8.792E-08
BCM u1 [-]:4.488E-07 BCM u3 [-]:-2.093E-06 BCM u10[-]:9.163E-08
BCM d1 [0]:2.487E-07 BCM d3 [0]:7.835E-07 BCM d10[0]:-2.335E-07
BCM d1 [+]:1.088E-07 BCM d3 [+]:4.077E-07 BCM d10[+]:-1.221E-07
BCM d1 [-]:1.729E-07 BCM d3 [-]:4.208E-07 BCM d10[-]:-1.182E-07
****************************
End-of-run EPICS data for Run Number 2019 at Sun Mar 30 21:25:55 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.00341118
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.29398
Right Arm arm angle : 0.197
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : 5.22461
Left Arm Bottom VDC Current : 4.3457
-----
Left Arm Q1 momentum : 0.00141286
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0002265
Left Arm Q2 gauss meter : 0.0007905
Left Arm Q2 power supply current : 0.0109768
Left Arm Q2 momentum : 0.00297075
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.37062
Left Arm D1 momentum : 0.00341118
Left Arm D1 NMR : 0.156658
Left Arm Q3 gauss meter : -7.77e-05
Left Arm Q3 power supply current : -0.000639462
Left Arm Q3 momentum : -1.60621e-06
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.000450689
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -3.93e-05
Right Arm Q2 power supply current : -0.0161391
Right Arm Q2 momentum : -3.75008e-05
Right Arm Q2 gauss meter : 0.0006242
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.318
Right Arm D1 momentum : 0.29398
Right Arm D1 NMR : 7.51882
Right Arm Q3 power supply current : -0.00144969
Right Arm Q3 momentum : -3.64326e-06
Right Arm Q3 gauss meter : 0.0001525
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0427493
Current on Unser monitor : 11.7181
Current on Upstream bcm : 0.0638202
Current on Downstream bcm : 0.0216785
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00302248
Hall C Current : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5717.78
Delta(E)/E width (MV_AI_DXWID) : 1.56081
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.29541
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.393555
-----
Right Arm Collimator : -0.00263672
HacR_HPE1313A:0_Ch58 : -0.558594
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.860352
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : -385557
Target type : -385557
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 281.8
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.3
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.00710569
HPH H2 loop 3 : 0.0170928
-----