keyword=End_of_Run_2020
****************************
Run Number: 2020
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=chamber test
PRESCALE FACTORS:ps1=1 ps2=16777215 ps3=1 ps4=16777215 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS : [0]: 12672 [+]: 6277 [-]: 6206
TIME : [0]: 2.040 mins [+]: 1.039 mins [-]: 1.039 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.33628 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 2.68% [+]: 5.87% [-]: 6.23%
TRIGGER RATES: PRES/REAL
T1[0] :96.7/96.7 Hz T2[0] : 0.0/1498.8 Hz T3[0] :13.4/13.4 Hz T4[0] : 0.0/7.2 Hz T5[0] : 3.7/3.7 Hz T6[0] : 0.0/3.8 Hz T7[0] : 0.0/2.5 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :97.5/97.5 Hz T2[+] : 0.0/1500.6 Hz T3[+] :13.3/13.3 Hz T4[+] : 0.0/6.9 Hz T5[+] : 3.8/3.8 Hz T6[+] : 0.0/3.6 Hz T7[+] : 0.0/2.6 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :95.9/95.9 Hz T2[-] : 0.0/1498.2 Hz T3[-] :13.7/13.7 Hz T4[-] : 0.0/7.5 Hz T5[-] : 3.5/3.5 Hz T6[-] : 0.0/3.9 Hz T7[-] : 0.0/3.9 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 11828/11828 T2[0] : 0/183422 T3[0] : 1642/1642 T4[0] : 0/885 T5[0] : 450/450 T6[0] : 0/460 T7[0] : 0/306 T8[0] : 1/125313
T1[+] : 6078/6078 T2[+] : 0/93562 T3[+] : 828/828 T4[+] : 0/428 T5[+] : 238/238 T6[+] : 0/225 T7[+] : 0/159 T8[+] : 0/63848
T1[-] : 5983/5983 T2[-] : 0/93437 T3[-] : 856/856 T4[-] : 0/468 T5[-] : 221/221 T6[-] : 0/245 T7[-] : 0/245 T8[-] : 0/63862
AVERAGE CURRENT
BCM x1 : 0.0063 uA BCM x3 : -0.0191uA BCM x10: -0.0004uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-2.643E+04 ppm BCM u3 : 1E+39 ppm BCM u10: -1.7E+04 ppm
BCM d1 :-1.032E+05 ppm BCM d3 : -2789 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:1.191E-06 BCM u3 [0]:-5.833E-06 BCM u10[0]:2.484E-07
BCM u1 [+]:5.878E-07 BCM u3 [+]:-2.972E-06 BCM u10[+]:1.249E-07
BCM u1 [-]:6.199E-07 BCM u3 [-]:-2.973E-06 BCM u10[-]:1.292E-07
BCM d1 [0]:3.541E-07 BCM d3 [0]:1.151E-06 BCM d10[0]:-3.363E-07
BCM d1 [+]:1.641E-07 BCM d3 [+]:6.01E-07 BCM d10[+]:-1.722E-07
BCM d1 [-]:2.02E-07 BCM d3 [-]:6.045E-07 BCM d10[-]:-1.691E-07
****************************
End-of-run EPICS data for Run Number 2020 at Sun Mar 30 21:29:34 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.00341731
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.29398
Right Arm arm angle : 0.197
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : -1.70898
Left Arm Bottom VDC Current : -0.0976562
-----
Left Arm Q1 momentum : 0.00156306
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0002146
Left Arm Q2 gauss meter : 0.0008265
Left Arm Q2 power supply current : 0.00984619
Left Arm Q2 momentum : 0.00306048
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.36828
Left Arm D1 momentum : 0.00341453
Left Arm D1 NMR : 0.156661
Left Arm Q3 gauss meter : -7.4e-05
Left Arm Q3 power supply current : -0.000417531
Left Arm Q3 momentum : -1.22828e-06
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00042948
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -2.81e-05
Right Arm Q2 power supply current : -0.0157361
Right Arm Q2 momentum : -3.76297e-05
Right Arm Q2 gauss meter : 0.0006215
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.318
Right Arm D1 momentum : 0.29398
Right Arm D1 NMR : 7.51882
Right Arm Q3 power supply current : -0.00136749
Right Arm Q3 momentum : -3.43669e-06
Right Arm Q3 gauss meter : 0.0001528
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0429992
Current on Unser monitor : 10.6298
Current on Upstream bcm : 0.0643093
Current on Downstream bcm : 0.0216892
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00313447
Hall C Current : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5717.78
Delta(E)/E width (MV_AI_DXWID) : 1.56311
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.87168
HacL_HPE1313A:0_Ch58 : -0.293945
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.393066
-----
Right Arm Collimator : -0.00297852
HacR_HPE1313A:0_Ch58 : -0.559082
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.861328
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : -385557
Target type : -385557
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 281.8
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.3
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.0118473
HPH H2 loop 3 : 0.00634721
-----