Run Number: 2026
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=chamber test + pulser
PRESCALE FACTORS:ps1=1 ps2=16777215 ps3=1 ps4=16777215 ps5=1 ps6=65535 ps7=65535 ps8=10
EVENTS : [0]: 10559 [+]: 5178 [-]: 5218
TIME : [0]: 1.076 mins [+]: 0.564 mins [-]: 0.564 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.20027 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 21.95% [+]: 26.69% [-]: 26.63%
TRIGGER RATES: PRES/REAL
T1[0] :97.2/97.2 Hz T2[0] : 0.0/1500.1 Hz T3[0] :13.1/13.1 Hz T4[0] : 0.0/7.4 Hz T5[0] : 3.3/3.3 Hz T6[0] : 0.0/3.7 Hz T7[0] : 0.0/2.4 Hz T8[0] :102.4/1024.0 Hz
T1[+] :96.5/96.5 Hz T2[+] : 0.0/1500.1 Hz T3[+] :13.0/13.0 Hz T4[+] : 0.0/7.4 Hz T5[+] : 3.1/3.1 Hz T6[+] : 0.0/4.0 Hz T7[+] : 0.0/2.7 Hz T8[+] :102.4/1024.0 Hz
T1[-] :97.4/97.4 Hz T2[-] : 0.0/1497.4 Hz T3[-] :13.6/13.6 Hz T4[-] : 0.0/7.8 Hz T5[-] : 3.4/3.4 Hz T6[-] : 0.0/3.5 Hz T7[-] : 0.0/3.5 Hz T8[-] :102.4/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 6279/6279 T2[0] : 0/96871 T3[0] : 849/849 T4[0] : 0/480 T5[0] : 211/211 T6[0] : 0/241 T7[0] : 0/156 T8[0] : 6612/66125
T1[+] : 3264/3264 T2[+] : 0/50748 T3[+] : 440/440 T4[+] : 0/250 T5[+] : 105/105 T6[+] : 0/135 T7[+] : 0/90 T8[+] : 3464/34641
T1[-] : 3299/3299 T2[-] : 0/50708 T3[-] : 460/460 T4[-] : 0/264 T5[-] : 114/114 T6[-] : 0/118 T7[-] : 0/118 T8[-] : 3467/34676
AVERAGE CURRENT
BCM x1 : 0.0057 uA BCM x3 : -0.0217uA BCM x10: -0.0005uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-2.335E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.848E+04 ppm
BCM d1 :-2.31E+05 ppm BCM d3 : 3232 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:5.908E-07 BCM u3 [0]:-3.079E-06 BCM u10[0]:1.184E-07
BCM u1 [+]:3.157E-07 BCM u3 [+]:-1.612E-06 BCM u10[+]:6.073E-08
BCM u1 [-]:3.311E-07 BCM u3 [-]:-1.615E-06 BCM u10[-]:6.309E-08
BCM d1 [0]:1.501E-07 BCM d3 [0]:2.709E-07 BCM d10[0]:-1.821E-07
BCM d1 [+]:6.259E-08 BCM d3 [+]:1.548E-07 BCM d10[+]:-9.702E-08
BCM d1 [-]:1.003E-07 BCM d3 [-]:1.54E-07 BCM d10[-]:-9.4E-08
****************************
End-of-run EPICS data for Run Number 2026 at Sun Mar 30 22:22:14 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.00340729
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.294034
Right Arm arm angle : 0.197
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : -0.927734
Left Arm Bottom VDC Current : 2.7832
-----
Left Arm Q1 momentum : 0.00133619
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0002256
Left Arm Q2 gauss meter : 0.000784
Left Arm Q2 power supply current : 0.00977505
Left Arm Q2 momentum : 0.0028278
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.3698
Left Arm D1 momentum : 0.00340729
Left Arm D1 NMR : 0.156682
Left Arm Q3 gauss meter : -7.77e-05
Left Arm Q3 power supply current : -0.000571755
Left Arm Q3 momentum : -1.04876e-06
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00152174
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -4.87e-05
Right Arm Q2 power supply current : -0.0141166
Right Arm Q2 momentum : -3.4322e-05
Right Arm Q2 gauss meter : 0.0006311
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.316
Right Arm D1 momentum : 0.294007
Right Arm D1 NMR : 7.51931
Right Arm Q3 power supply current : -0.000892977
Right Arm Q3 momentum : -3.6996e-06
Right Arm Q3 gauss meter : 0.0001521
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0428584
Current on Unser monitor : 10.9807
Current on Upstream bcm : 0.064085
Current on Downstream bcm : 0.0216317
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 24.238
Hall C Current : 24.75
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5717.78
Delta(E)/E width (MV_AI_DXWID) : 1.3675
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871582
HacL_HPE1313A:0_Ch58 : -0.29541
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.39209
-----
Right Arm Collimator : -0.00673828
HacR_HPE1313A:0_Ch58 : -0.55957
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.860352
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : -385557
Target type : -385557
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 281.9
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.4
HPH He loop 1 : 0.0970926
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.00634721
-----