Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 22:49:38 on March 30, 2008

    Entry number 229113

    keyword=End_of_Run_2027
    ****************************
     Run Number: 2027
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=chamber test + pulser
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 248395       [+]: 122560       [-]: 122145       
    TIME     : [0]: 26.286 mins  [+]: 12.983 mins  [-]: 12.984 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -5.78402 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  24.73%      [+]:  24.87%      [-]:  24.98%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :96.7/96.7 Hz   T2[0] : 0.0/1498.9 Hz   T3[0] :13.5/13.5 Hz   T4[0] : 0.0/7.3  Hz   T5[0] : 3.4/3.4  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.6  Hz   T8[0] :102.4/1024.0 Hz   
    T1[+] :96.8/96.8 Hz   T2[+] : 0.0/1499.6 Hz   T3[+] :13.7/13.7 Hz   T4[+] : 0.0/7.2  Hz   T5[+] : 3.4/3.4  Hz   T6[+] : 0.0/3.9  Hz   T7[+] : 0.0/2.6  Hz   T8[+] :102.4/1024.0 Hz   
    T1[-] :96.6/96.6 Hz   T2[-] : 0.0/1497.8 Hz   T3[-] :13.3/13.3 Hz   T4[-] : 0.0/7.4  Hz   T5[-] : 3.3/3.3  Hz   T6[-] : 0.0/3.6  Hz   T7[-] : 0.0/3.6  Hz   T8[-] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 152566/152566   T2[0] :      0/2364061  T3[0] :  21293/21293    T4[0] :      0/11511    T5[0] :   5333/5333     T6[0] :      0/5916     T7[0] :      0/4089     T8[0] : 161503/1615033  
    T1[+] :  75378/75378    T2[+] :      0/1168176  T3[+] :  10641/10641    T4[+] :      0/5597     T5[+] :   2655/2655     T6[+] :      0/3010     T7[+] :      0/2040     T8[+] :  79768/797688   
    T1[-] :  75273/75273    T2[-] :      0/1166884  T3[-] :  10371/10371    T4[-] :      0/5788     T5[-] :   2595/2595     T6[-] :      0/2832     T7[-] :      0/2832     T8[-] :  79774/797741   
    
    AVERAGE CURRENT
    BCM x1 : 0.0058 uA  BCM x3 : -0.0226uA  BCM x10: -0.0004uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.38E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.55E+04 ppm     
    BCM d1 :-1.207E+05 ppm     BCM d3 :-2.984E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:1.461E-05      BCM u3 [0]:-7.516E-05     BCM u10[0]:3.094E-06      
    BCM u1 [+]:6.959E-06      BCM u3 [+]:-3.712E-05     BCM u10[+]:1.505E-06      
    BCM u1 [-]:7.447E-06      BCM u3 [-]:-3.713E-05     BCM u10[-]:1.552E-06      
    
    BCM d1 [0]:3.737E-06      BCM d3 [0]:3.772E-06      BCM d10[0]:-4.404E-06     
    BCM d1 [+]:1.632E-06      BCM d3 [+]:1.96E-06       BCM d10[+]:-2.2E-06       
    BCM d1 [-]:2.081E-06      BCM d3 [-]:2.081E-06      BCM d10[-]:-2.15E-06      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2027 at Sun Mar 30 22:49:29 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00344153
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.29398
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 2.29492
    Left Arm Bottom VDC Current : 3.07617
    -----
    Left Arm Q1 momentum : 0.00124231
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002341
    Left Arm Q2 gauss meter : 0.0007881
    Left Arm Q2 power supply current : 0.0103366
    Left Arm Q2 momentum : 0.00281812
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.36898
    Left Arm D1 momentum : 0.00341703
    Left Arm D1 NMR : 0.156657
    Left Arm Q3 gauss meter : -7.76e-05
    Left Arm Q3 power supply current : -0.000406247
    Left Arm Q3 momentum : -1.02042e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.000790032
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -3.21e-05
    Right Arm Q2 power supply current : -0.0164016
    Right Arm Q2 momentum : -3.62809e-05
    Right Arm Q2 gauss meter : 0.0006181
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.318
    Right Arm D1 momentum : 0.294007
    Right Arm D1 NMR : 7.51886
    Right Arm Q3 power supply current : -0.000810778
    Right Arm Q3 momentum : -2.60099e-06
    Right Arm Q3 gauss meter : 0.0001524
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0428956
    Current on Unser monitor : 10.7708
    Current on Upstream bcm : 0.0640931
    Current on Downstream bcm : 0.0216981
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00342385
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.56353
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.294922
    HacL_HPE1313A:0_Ch55 : 23.3887
    HacL_HPE1313A:0_Ch54 : -0.393555
    -----
    Right Arm Collimator : -0.00698242
    HacR_HPE1313A:0_Ch58 : -0.55957
    HacR_HPE1313A:0_Ch55 : 22.2656
    HacR_HPE1313A:0_Ch54 : -0.861328
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.9
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00634721
    -----