Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 22:52:15 on March 30, 2008
Entry number 229115
keyword=End_of_Run_2028
****************************
Run Number: 2028
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=chamber test + pulser
PRESCALE FACTORS:ps1=1 ps2=16777215 ps3=1 ps4=16777215 ps5=1 ps6=65535 ps7=65535 ps8=10
EVENTS : [0]: 20692 [+]: 10176 [-]: 10225
TIME : [0]: 2.153 mins [+]: 1.094 mins [-]: 1.094 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.22667 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 23.86% [+]: 25.89% [-]: 26.52%
TRIGGER RATES: PRES/REAL
T1[0] :97.7/97.7 Hz T2[0] : 0.0/1510.9 Hz T3[0] :13.6/13.6 Hz T4[0] : 0.0/7.4 Hz T5[0] : 3.4/3.4 Hz T6[0] : 0.0/3.7 Hz T7[0] : 0.0/2.7 Hz T8[0] :102.4/1024.0 Hz
T1[+] :96.6/96.6 Hz T2[+] : 0.0/1504.1 Hz T3[+] :13.6/13.6 Hz T4[+] : 0.0/7.4 Hz T5[+] : 3.3/3.3 Hz T6[+] : 0.0/3.6 Hz T7[+] : 0.0/2.7 Hz T8[+] :102.4/1024.0 Hz
T1[-] :99.3/99.3 Hz T2[-] : 0.0/1517.4 Hz T3[-] :13.7/13.7 Hz T4[-] : 0.0/7.4 Hz T5[-] : 3.5/3.5 Hz T6[-] : 0.0/3.9 Hz T7[-] : 0.0/3.9 Hz T8[-] :102.4/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 12625/12625 T2[0] : 0/195164 T3[0] : 1759/1759 T4[0] : 0/955 T5[0] : 433/433 T6[0] : 0/484 T7[0] : 0/351 T8[0] : 13226/132267
T1[+] : 6338/6338 T2[+] : 0/98718 T3[+] : 890/890 T4[+] : 0/484 T5[+] : 217/217 T6[+] : 0/238 T7[+] : 0/177 T8[+] : 6721/67210
T1[-] : 6523/6523 T2[-] : 0/99628 T3[-] : 899/899 T4[-] : 0/485 T5[-] : 230/230 T6[-] : 0/255 T7[-] : 0/255 T8[-] : 6723/67234
AVERAGE CURRENT
BCM x1 : 0.0061 uA BCM x3 : -0.0215uA BCM x10: -0.0004uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-2.597E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.575E+04 ppm
BCM d1 :-1.094E+05 ppm BCM d3 :-2.916E+04 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:1.224E-06 BCM u3 [0]:-6.153E-06 BCM u10[0]:2.548E-07
BCM u1 [+]:6.24E-07 BCM u3 [+]:-3.127E-06 BCM u10[+]:1.269E-07
BCM u1 [-]:6.575E-07 BCM u3 [-]:-3.128E-06 BCM u10[-]:1.31E-07
BCM d1 [0]:3.445E-07 BCM d3 [0]:5.87E-07 BCM d10[0]:-3.581E-07
BCM d1 [+]:1.544E-07 BCM d3 [+]:3.016E-07 BCM d10[+]:-1.843E-07
BCM d1 [-]:1.924E-07 BCM d3 [-]:3.198E-07 BCM d10[-]:-1.795E-07
****************************
End-of-run EPICS data for Run Number 2028 at Sun Mar 30 22:52:10 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.0034187
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.293953
Right Arm arm angle : 0.197
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : -0.488281
-----
Left Arm Q1 momentum : 0.00131272
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0002192
Left Arm Q2 gauss meter : 0.0008015
Left Arm Q2 power supply current : 0.0105088
Left Arm Q2 momentum : 0.00279569
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.36639
Left Arm D1 momentum : 0.00345238
Left Arm D1 NMR : 0.156658
Left Arm Q3 gauss meter : -7.53e-05
Left Arm Q3 power supply current : -0.000496524
Left Arm Q3 momentum : -1.24718e-06
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00147402
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -6.36e-05
Right Arm Q2 power supply current : -0.0159469
Right Arm Q2 momentum : -3.70541e-05
Right Arm Q2 gauss meter : 0.0006308
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.317
Right Arm D1 momentum : 0.293925
Right Arm D1 NMR : 7.51886
Right Arm Q3 power supply current : -0.000833196
Right Arm Q3 momentum : -2.09394e-06
Right Arm Q3 gauss meter : 0.0001522
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0429287
Current on Unser monitor : 11.7022
Current on Upstream bcm : 0.0641718
Current on Downstream bcm : 0.0216856
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 5.08879
Hall C Current : 5.13
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5717.78
Delta(E)/E width (MV_AI_DXWID) : 1.37324
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.29541
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.393066
-----
Right Arm Collimator : -0.00610352
HacR_HPE1313A:0_Ch58 : -0.559082
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.861816
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : -385557
Target type : -385557
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 281.9
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.3
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.011068
-----