     Run Number: 2029
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=vme stress test V=6.0V, Rate= 56.1 Hz
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : [0]: 109105       [+]: 53790        [-]: 53728        
    TIME     : [0]: 6.646 mins  [+]: 3.307 mins  [-]: 3.307 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.45389 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  75.81%      [+]:  76.02%      [-]:  76.07%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :97.3/97.3 Hz   T2[0] : 0.0/1506.2 Hz   T3[0] :13.4/13.4 Hz   T4[0] : 0.0/7.2  Hz   T5[0] : 3.3/3.3  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.5  Hz   T8[0] :1024.0/1024.0 Hz   
    T1[+] :96.4/96.4 Hz   T2[+] : 0.0/1504.7 Hz   T3[+] :13.6/13.6 Hz   T4[+] : 0.0/7.4  Hz   T5[+] : 3.2/3.2  Hz   T6[+] : 0.0/3.8  Hz   T7[+] : 0.0/2.4  Hz   T8[+] :1024.0/1024.0 Hz   
    T1[-] :98.2/98.2 Hz   T2[-] : 0.0/1507.4 Hz   T3[-] :13.2/13.2 Hz   T4[-] : 0.0/7.1  Hz   T5[-] : 3.5/3.5  Hz   T6[-] : 0.0/3.7  Hz   T7[-] : 0.0/3.7  Hz   T8[-] :1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  38804/38804    T2[0] :      0/600559   T3[0] :   5331/5331     T4[0] :      0/2889     T5[0] :   1326/1326     T6[0] :      0/1496     T7[0] :      0/986      T8[0] : 408302/408302   
    T1[+] :  19126/19126    T2[+] :      0/298575   T3[+] :   2692/2692     T4[+] :      0/1475     T5[+] :    633/633      T6[+] :      0/758      T7[+] :      0/473      T8[+] : 203186/203186   
    T1[-] :  19478/19478    T2[-] :      0/299093   T3[-] :   2614/2614     T4[-] :      0/1410     T5[-] :    687/687      T6[-] :      0/726      T7[-] :      0/726      T8[-] : 203175/203175   
    
    AVERAGE CURRENT
    BCM x1 : 0.0060 uA  BCM x3 : -0.0226uA  BCM x10: -0.0004uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.011E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.183E+04 ppm     
    BCM d1 :-1.783E+05 ppm     BCM d3 :-4.598E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:3.75E-06       BCM u3 [0]:-1.901E-05     BCM u10[0]:7.563E-07      
    BCM u1 [+]:1.793E-06      BCM u3 [+]:-9.461E-06     BCM u10[+]:3.714E-07      
    BCM u1 [-]:1.905E-06      BCM u3 [-]:-9.456E-06     BCM u10[-]:3.803E-07      
    
    BCM d1 [0]:1.07E-06       BCM d3 [0]:9.879E-07      BCM d10[0]:-1.108E-06     
    BCM d1 [+]:4.334E-07      BCM d3 [+]:4.976E-07      BCM d10[+]:-5.586E-07     
    BCM d1 [-]:6.215E-07      BCM d3 [-]:5.455E-07      BCM d10[-]:-5.416E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2029 at Sun Mar 30 23:02:10 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00340423
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.293953
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : -2.09961
    Left Arm Bottom VDC Current : 2.49023
    -----
    Left Arm Q1 momentum : 0.00134714
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002229
    Left Arm Q2 gauss meter : 0.000801
    Left Arm Q2 power supply current : 0.00995476
    Left Arm Q2 momentum : 0.00285463
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.36392
    Left Arm D1 momentum : 0.00339198
    Left Arm D1 NMR : 0.156667
    Left Arm Q3 gauss meter : -7.39e-05
    Left Arm Q3 power supply current : -0.00046267
    Left Arm Q3 momentum : -1.44559e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00145811
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.26e-05
    Right Arm Q2 power supply current : -0.0158138
    Right Arm Q2 momentum : -3.67448e-05
    Right Arm Q2 gauss meter : 0.0006295
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.317
    Right Arm D1 momentum : 0.293953
    Right Arm D1 NMR : 7.51894
    Right Arm Q3 power supply current : -0.00143474
    Right Arm Q3 momentum : -3.6057e-06
    Right Arm Q3 gauss meter : 0.0001526
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0428852
    Current on Unser monitor : 10.7053
    Current on Upstream bcm : 0.0641116
    Current on Downstream bcm : 0.0216587
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.30041
    Hall C Current : 2.43
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.35797
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.29541
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.393066
    -----
    Right Arm Collimator : -0.00283203
    HacR_HPE1313A:0_Ch58 : -0.560059
    HacR_HPE1313A:0_Ch55 : 22.168
    HacR_HPE1313A:0_Ch54 : -0.861816
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.9
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00293052
    -----