    keyword=End_of_Run_2030
    ****************************
     Run Number: 2030
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=vme stress test: V=5.0V, Rate= 61.0 Hz
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : [0]: 134427       [+]: 66290        [-]: 66223        
    TIME     : [0]: 8.202 mins  [+]: 4.075 mins  [-]: 4.075 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.65328 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  75.84%      [+]:  76.04%      [-]:  76.03%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :97.1/97.1 Hz   T2[0] : 0.0/1510.6 Hz   T3[0] :13.3/13.3 Hz   T4[0] : 0.0/7.4  Hz   T5[0] : 3.4/3.4  Hz   T6[0] : 0.0/3.7  Hz   T7[0] : 0.0/2.6  Hz   T8[0] :1024.0/1024.0 Hz   
    T1[+] :97.4/97.4 Hz   T2[+] : 0.0/1509.3 Hz   T3[+] :13.4/13.4 Hz   T4[+] : 0.0/7.5  Hz   T5[+] : 3.2/3.2  Hz   T6[+] : 0.0/3.7  Hz   T7[+] : 0.0/2.6  Hz   T8[+] :1024.0/1024.0 Hz   
    T1[-] :96.7/96.7 Hz   T2[-] : 0.0/1511.7 Hz   T3[-] :13.2/13.2 Hz   T4[-] : 0.0/7.4  Hz   T5[-] : 3.6/3.6  Hz   T6[-] : 0.0/3.8  Hz   T7[-] : 0.0/3.8  Hz   T8[-] :1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  47767/47767    T2[0] :      0/743401   T3[0] :   6533/6533     T4[0] :      0/3665     T5[0] :   1667/1667     T6[0] :      0/1845     T7[0] :      0/1274     T8[0] : 503931/503931   
    T1[+] :  23822/23822    T2[+] :      0/369000   T3[+] :   3278/3278     T4[+] :      0/1832     T5[+] :    794/794      T6[+] :      0/907      T7[+] :      0/627      T8[+] : 250346/250346   
    T1[-] :  23644/23644    T2[-] :      0/369557   T3[-] :   3222/3222     T4[-] :      0/1808     T5[-] :    868/868      T6[-] :      0/934      T7[-] :      0/934      T8[-] : 250339/250339   
    
    AVERAGE CURRENT
    BCM x1 : 0.0060 uA  BCM x3 : -0.0211uA  BCM x10: -0.0006uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-2.842E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.567E+04 ppm     
    BCM d1 :-1.408E+05 ppm     BCM d3 :-1.096E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:4.607E-06      BCM u3 [0]:-2.345E-05     BCM u10[0]:8.219E-07      
    BCM u1 [+]:2.26E-06       BCM u3 [+]:-1.165E-05     BCM u10[+]:4.019E-07      
    BCM u1 [-]:2.392E-06      BCM u3 [-]:-1.165E-05     BCM u10[-]:4.146E-07      
    
    BCM d1 [0]:1.314E-06      BCM d3 [0]:2.655E-06      BCM d10[0]:-1.4E-06       
    BCM d1 [+]:5.667E-07      BCM d3 [+]:1.363E-06      BCM d10[+]:-7.001E-07     
    BCM d1 [-]:7.525E-07      BCM d3 [-]:1.393E-06      BCM d10[-]:-6.901E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2030 at Sun Mar 30 23:10:56 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00343958
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.294007
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 3.22266
    Left Arm Bottom VDC Current : 1.36719
    -----
    Left Arm Q1 momentum : 0.00157871
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002145
    Left Arm Q2 gauss meter : 0.0008373
    Left Arm Q2 power supply current : 0.0103628
    Left Arm Q2 momentum : 0.00306312
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.3607
    Left Arm D1 momentum : 0.00340228
    Left Arm D1 NMR : 0.156672
    Left Arm Q3 gauss meter : -7.86e-05
    Left Arm Q3 power supply current : -0.00026707
    Left Arm Q3 momentum : -6.70829e-07
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00110286
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -4.08e-05
    Right Arm Q2 power supply current : -0.0152296
    Right Arm Q2 momentum : -3.68135e-05
    Right Arm Q2 gauss meter : 0.0006313
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.317
    Right Arm D1 momentum : 0.294007
    Right Arm D1 NMR : 7.51906
    Right Arm Q3 power supply current : -0.000724843
    Right Arm Q3 momentum : -2.25356e-06
    Right Arm Q3 gauss meter : 0.0001525
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0424171
    Current on Unser monitor : 11.8836
    Current on Upstream bcm : 0.0635355
    Current on Downstream bcm : 0.0212988
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.63902
    Hall C Current : 5.19
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 2.32575
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.294434
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.392578
    -----
    Right Arm Collimator : -0.00288086
    HacR_HPE1313A:0_Ch58 : -0.560059
    HacR_HPE1313A:0_Ch55 : 22.2168
    HacR_HPE1313A:0_Ch54 : -0.861816
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.9
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00356948
    HPH H2 loop 3 : 0.011068
    -----