    keyword=End_of_Run_2032
    ****************************
     Run Number: 2032
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=vme stress test: V=3.0V, Rate= 105.3 Hz; ps1=1, ps3=1, ps5=1, ps8=1
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : [0]: 82520        [+]: 40674        [-]: 40612        
    TIME     : [0]: 5.026 mins  [+]: 2.511 mins  [-]: 2.512 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.64414 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  75.80%      [+]:  76.13%      [-]:  76.17%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :96.7/96.7 Hz   T2[0] : 0.0/1503.7 Hz   T3[0] :13.5/13.5 Hz   T4[0] : 0.0/7.2  Hz   T5[0] : 3.4/3.4  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.6  Hz   T8[0] :1024.0/1024.0 Hz   
    T1[+] :96.9/96.9 Hz   T2[+] : 0.0/1503.1 Hz   T3[+] :13.4/13.4 Hz   T4[+] : 0.0/7.4  Hz   T5[+] : 3.4/3.4  Hz   T6[+] : 0.0/3.8  Hz   T7[+] : 0.0/2.6  Hz   T8[+] :1024.0/1024.0 Hz   
    T1[-] :96.8/96.8 Hz   T2[-] : 0.0/1505.4 Hz   T3[-] :13.5/13.5 Hz   T4[-] : 0.0/7.1  Hz   T5[-] : 3.5/3.5  Hz   T6[-] : 0.0/3.7  Hz   T7[-] : 0.0/3.7  Hz   T8[-] :1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  29173/29173    T2[0] :      0/453440   T3[0] :   4067/4067     T4[0] :      0/2169     T5[0] :   1029/1029     T6[0] :      0/1131     T7[0] :      0/788      T8[0] : 308782/308782   
    T1[+] :  14596/14596    T2[+] :      0/226478   T3[+] :   2023/2023     T4[+] :      0/1110     T5[+] :    511/511      T6[+] :      0/570      T7[+] :      0/389      T8[+] : 154289/154289   
    T1[-] :  14584/14584    T2[-] :      0/226862   T3[-] :   2034/2034     T4[-] :      0/1066     T5[-] :    522/522      T6[-] :      0/559      T7[-] :      0/559      T8[-] : 154311/154311   
    
    AVERAGE CURRENT
    BCM x1 : 0.0061 uA  BCM x3 : -0.0175uA  BCM x10: -0.0008uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.276E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.874E+04 ppm     
    BCM d1 :-1.188E+05 ppm     BCM d3 :-1.443E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.819E-06      BCM u3 [0]:-1.437E-05     BCM u10[0]:4.172E-07      
    BCM u1 [+]:1.348E-06      BCM u3 [+]:-7.18E-06      BCM u10[+]:2.051E-07      
    BCM u1 [-]:1.44E-06       BCM u3 [-]:-7.18E-06      BCM u10[-]:2.129E-07      
    
    BCM d1 [0]:8.623E-07      BCM d3 [0]:3.803E-06      BCM d10[0]:-8.756E-07     
    BCM d1 [+]:3.716E-07      BCM d3 [+]:1.886E-06      BCM d10[+]:-4.399E-07     
    BCM d1 [-]:4.719E-07      BCM d3 [-]:1.942E-06      BCM d10[-]:-4.33E-07      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2032 at Sun Mar 30 23:33:42 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00342789
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.294034
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 3.27148
    Left Arm Bottom VDC Current : -0.195312
    -----
    Left Arm Q1 momentum : 0.00121728
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.000234
    Left Arm Q2 gauss meter : 0.0007915
    Left Arm Q2 power supply current : 0.0104302
    Left Arm Q2 momentum : 0.00281284
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.36215
    Left Arm D1 momentum : 0.00339532
    Left Arm D1 NMR : 0.156686
    Left Arm Q3 gauss meter : -8.4e-05
    Left Arm Q3 power supply current : -0.00041377
    Left Arm Q3 momentum : -1.03931e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.000588547
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -3.11e-05
    Right Arm Q2 power supply current : -0.0141758
    Right Arm Q2 momentum : -3.43135e-05
    Right Arm Q2 gauss meter : 0.0006202
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.316
    Right Arm D1 momentum : 0.294007
    Right Arm D1 NMR : 7.51939
    Right Arm Q3 power supply current : -0.00020176
    Right Arm Q3 momentum : -5.07052e-07
    Right Arm Q3 gauss meter : 0.0001523
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0425057
    Current on Unser monitor : 11.7066
    Current on Upstream bcm : 0.0636609
    Current on Downstream bcm : 0.0213505
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.0396748
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.56297
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.296387
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.39209
    -----
    Right Arm Collimator : -0.00610352
    HacR_HPE1313A:0_Ch58 : -0.55957
    HacR_HPE1313A:0_Ch55 : 22.2168
    HacR_HPE1313A:0_Ch54 : -0.861328
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.9
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00356948
    HPH H2 loop 3 : 0.011068
    -----