Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 23:41:12 on March 30, 2008

    Entry number 229125

    keyword=End_of_Run_2033
    ****************************
     Run Number: 2033
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=vme stress test: V=3.0V, Rate= 172.5 Hz; ps1=1, ps3=1, ps5=1, ps8=1
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : [0]: 30773        [+]: 15188        [-]: 15160        
    TIME     : [0]: 1.840 mins  [+]: 0.941 mins  [-]: 0.941 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.36942 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  75.39%      [+]:  76.25%      [-]:  76.31%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :98.2/98.2 Hz   T2[0] : 0.0/1501.5 Hz   T3[0] :14.0/14.0 Hz   T4[0] : 0.0/7.3  Hz   T5[0] : 3.3/3.3  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.4  Hz   T8[0] :1024.0/1024.0 Hz   
    T1[+] :97.6/97.6 Hz   T2[+] : 0.0/1499.9 Hz   T3[+] :14.3/14.3 Hz   T4[+] : 0.0/7.3  Hz   T5[+] : 3.6/3.6  Hz   T6[+] : 0.0/4.1  Hz   T7[+] : 0.0/2.5  Hz   T8[+] :1024.0/1024.0 Hz   
    T1[-] :99.0/99.0 Hz   T2[-] : 0.0/1501.5 Hz   T3[-] :13.7/13.7 Hz   T4[-] : 0.0/7.3  Hz   T5[-] : 3.0/3.0  Hz   T6[-] : 0.0/3.4  Hz   T7[-] : 0.0/3.4  Hz   T8[-] :1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  10841/10841    T2[0] :      0/165726   T3[0] :   1541/1541     T4[0] :      0/811      T5[0] :    361/361      T6[0] :      0/414      T7[0] :      0/260      T8[0] : 113019/113019   
    T1[+] :   5513/5513     T2[+] :      0/84714    T3[+] :    807/807      T4[+] :      0/413      T5[+] :    204/204      T6[+] :      0/231      T7[+] :      0/142      T8[+] :  57835/57835    
    T1[-] :   5589/5589     T2[-] :      0/84763    T3[-] :    774/774      T4[-] :      0/411      T5[-] :    167/167      T6[-] :      0/194      T7[-] :      0/194      T8[-] :  57808/57808    
    
    AVERAGE CURRENT
    BCM x1 : 0.0062 uA  BCM x3 : -0.0175uA  BCM x10: -0.0006uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-2.879E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.668E+04 ppm     
    BCM d1 :-8.484E+04 ppm     BCM d3 :-1.351E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:1.046E-06      BCM u3 [0]:-5.263E-06     BCM u10[0]:1.887E-07      
    BCM u1 [+]:5.202E-07      BCM u3 [+]:-2.692E-06     BCM u10[+]:9.44E-08       
    BCM u1 [-]:5.508E-07      BCM u3 [-]:-2.693E-06     BCM u10[-]:9.756E-08      
    
    BCM d1 [0]:3.146E-07      BCM d3 [0]:1.402E-06      BCM d10[0]:-3.122E-07     
    BCM d1 [+]:1.498E-07      BCM d3 [+]:7.085E-07      BCM d10[+]:-1.623E-07     
    BCM d1 [-]:1.775E-07      BCM d3 [-]:7.276E-07      BCM d10[-]:-1.577E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2033 at Sun Mar 30 23:41:03 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00344654
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.293953
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 2.09961
    Left Arm Bottom VDC Current : 2.14844
    -----
    Left Arm Q1 momentum : 0.00131742
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002248
    Left Arm Q2 gauss meter : 0.000816
    Left Arm Q2 power supply current : 0.0102355
    Left Arm Q2 momentum : 0.00292061
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.36855
    Left Arm D1 momentum : 0.00344654
    Left Arm D1 NMR : 0.156683
    Left Arm Q3 gauss meter : -7.73e-05
    Left Arm Q3 power supply current : -0.000504047
    Left Arm Q3 momentum : -1.26607e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00173383
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -5.27e-05
    Right Arm Q2 power supply current : -0.0149227
    Right Arm Q2 momentum : -3.46743e-05
    Right Arm Q2 gauss meter : 0.0006283
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.316
    Right Arm D1 momentum : 0.293953
    Right Arm D1 NMR : 7.51933
    Right Arm Q3 power supply current : -0.000878032
    Right Arm Q3 momentum : -1.17373e-06
    Right Arm Q3 gauss meter : 0.0001522
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0425255
    Current on Unser monitor : 10.6468
    Current on Upstream bcm : 0.0634976
    Current on Downstream bcm : 0.0215535
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.0268018
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.37285
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.295898
    HacL_HPE1313A:0_Ch55 : 23.4375
    HacL_HPE1313A:0_Ch54 : -0.391113
    -----
    Right Arm Collimator : -0.00522461
    HacR_HPE1313A:0_Ch58 : -0.55957
    HacR_HPE1313A:0_Ch55 : 22.2168
    HacR_HPE1313A:0_Ch54 : -0.861328
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 281.9
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00123869
    HPH H2 loop 3 : 0.00634721
    -----