Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 00:38:17 on March 31, 2008
Entry number 229133
keyword=End_of_Run_2037
****************************
Run Number: 2037
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=tdc reference channel test
PRESCALE FACTORS:ps1=65535 ps2=16777215 ps3=16777215 ps4=16777215 ps5=65535 ps6=65535 ps7=65535 ps8=1
EVENTS : [0]: 4630 [+]: 2277 [-]: 2284
TIME : [0]: 0.250 mins [+]: 0.156 mins [-]: 0.157 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.10725 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 69.82% [+]: 76.25% [-]: 76.33%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/98.5 Hz T2[0] : 0.0/1522.8 Hz T3[0] : 0.0/13.3 Hz T4[0] : 0.0/7.7 Hz T5[0] : 0.0/3.8 Hz T6[0] : 0.0/3.7 Hz T7[0] : 0.0/2.5 Hz T8[0] :1024.0/1024.0 Hz
T1[+] : 0.0/100.2 Hz T2[+] : 0.0/1523.1 Hz T3[+] : 0.0/12.7 Hz T4[+] : 0.0/8.5 Hz T5[+] : 0.0/3.3 Hz T6[+] : 0.0/4.0 Hz T7[+] : 0.0/2.7 Hz T8[+] :1024.0/1024.0 Hz
T1[-] : 0.0/98.4 Hz T2[-] : 0.0/1529.4 Hz T3[-] : 0.0/14.6 Hz T4[-] : 0.0/7.2 Hz T5[-] : 0.0/3.7 Hz T6[-] : 0.0/3.6 Hz T7[-] : 0.0/3.6 Hz T8[-] :1024.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/1476 T2[0] : 0/22813 T3[0] : 0/200 T4[0] : 0/116 T5[0] : 0/57 T6[0] : 0/56 T7[0] : 0/37 T8[0] : 15341/15341
T1[+] : 0/938 T2[+] : 0/14261 T3[+] : 0/119 T4[+] : 0/80 T5[+] : 0/31 T6[+] : 0/37 T7[+] : 0/25 T8[+] : 9588/9588
T1[-] : 0/927 T2[-] : 0/14414 T3[-] : 0/138 T4[-] : 0/68 T5[-] : 0/35 T6[-] : 0/34 T7[-] : 0/34 T8[-] : 9651/9651
AVERAGE CURRENT
BCM x1 : 0.0058 uA BCM x3 : -0.0175uA BCM x10: -0.0008uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-2.647E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.649E+04 ppm
BCM d1 :-1.588E+05 ppm BCM d3 : 4284 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:1.354E-07 BCM u3 [0]:-7.142E-07 BCM u10[0]:2.049E-08
BCM u1 [+]:8.043E-08 BCM u3 [+]:-4.461E-07 BCM u10[+]:1.322E-08
BCM u1 [-]:8.536E-08 BCM u3 [-]:-4.496E-07 BCM u10[-]:1.376E-08
BCM d1 [0]:3.767E-08 BCM d3 [0]:1.889E-07 BCM d10[0]:-4.35E-08
BCM d1 [+]:1.933E-08 BCM d3 [+]:1.183E-07 BCM d10[+]:-2.762E-08
BCM d1 [-]:2.681E-08 BCM d3 [-]:1.181E-07 BCM d10[-]:-2.718E-08
****************************
End-of-run EPICS data for Run Number 2037 at Mon Mar 31 00:38:01 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.00343401
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.294007
Right Arm arm angle : 0.197
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : 2.00195
Left Arm Bottom VDC Current : 1.95312
-----
Left Arm Q1 momentum : 0.0014864
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.000214
Left Arm Q2 gauss meter : 0.0008425
Left Arm Q2 power supply current : 0.00992855
Left Arm Q2 momentum : 0.00303717
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.35953
Left Arm D1 momentum : 0.00342789
Left Arm D1 NMR : 0.156673
Left Arm Q3 gauss meter : -8.25e-05
Left Arm Q3 power supply current : -0.000635701
Left Arm Q3 momentum : -1.59676e-06
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00191941
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -6.97e-05
Right Arm Q2 power supply current : -0.0162353
Right Arm Q2 momentum : -3.77242e-05
Right Arm Q2 gauss meter : 0.0006294
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.316
Right Arm D1 momentum : 0.29398
Right Arm D1 NMR : 7.51907
Right Arm Q3 power supply current : -0.00157298
Right Arm Q3 momentum : -3.95313e-06
Right Arm Q3 gauss meter : 0.0001524
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0422536
Current on Unser monitor : 11.1042
Current on Upstream bcm : 0.0632569
Current on Downstream bcm : 0.0212502
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 28.9766
Hall C Current : 39.12
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5717.78
Delta(E)/E width (MV_AI_DXWID) : 1.55249
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.29541
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.392578
-----
Right Arm Collimator : -0.00239258
HacR_HPE1313A:0_Ch58 : -0.560547
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.862305
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : -385557
Target type : -385557
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 281.9
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.4
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.00710569
HPH H2 loop 3 : 0.011068
-----