Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 01:32:36 on March 31, 2008

    Entry number 229144

    keyword=End_of_Run_2042
    ****************************
     Run Number: 2042
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=vme stress test: Vth = 1.52V, monitor rate ~ 20KHz
     
    
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 30119        [+]: 14794        [-]: 14874        
    TIME     : [0]: 4.819 mins  [+]: 2.407 mins  [-]: 2.407 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.32274 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   2.83%      [+]:   4.14%      [-]:   4.30%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :97.4/97.4 Hz   T2[0] : 0.0/1503.2 Hz   T3[0] :13.2/13.2 Hz   T4[0] : 0.0/7.3  Hz   T5[0] : 3.5/3.5  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.6  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :97.4/97.4 Hz   T2[+] : 0.0/1501.8 Hz   T3[+] :13.0/13.0 Hz   T4[+] : 0.0/7.0  Hz   T5[+] : 3.5/3.5  Hz   T6[+] : 0.0/3.7  Hz   T7[+] : 0.0/2.6  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :97.6/97.6 Hz   T2[-] : 0.0/1505.5 Hz   T3[-] :13.5/13.5 Hz   T4[-] : 0.0/7.6  Hz   T5[-] : 3.4/3.4  Hz   T6[-] : 0.0/3.8  Hz   T7[-] : 0.0/3.8  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  28169/28169    T2[0] :      0/434649   T3[0] :   3825/3825     T4[0] :      0/2116     T5[0] :   1000/1000     T6[0] :      0/1086     T7[0] :      0/743      T8[0] :      4/296086   
    T1[+] :  14065/14065    T2[+] :      0/216918   T3[+] :   1879/1879     T4[+] :      0/1014     T5[+] :    512/512      T6[+] :      0/541      T7[+] :      0/374      T8[+] :      2/147901   
    T1[-] :  14092/14092    T2[-] :      0/217417   T3[-] :   1944/1944     T4[-] :      0/1093     T5[-] :    494/494      T6[-] :      0/545      T7[-] :      0/545      T8[-] :      2/147879   
    
    AVERAGE CURRENT
    BCM x1 : 0.0061 uA  BCM x3 : -0.0235uA  BCM x10: -0.0004uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.336E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.155E+04 ppm     
    BCM d1 :-1.295E+05 ppm     BCM d3 :-1.535E+05 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.796E-06      BCM u3 [0]:-1.378E-05     BCM u10[0]:5.893E-07      
    BCM u1 [+]:1.345E-06      BCM u3 [+]:-6.883E-06     BCM u10[+]:2.898E-07      
    BCM u1 [-]:1.438E-06      BCM u3 [-]:-6.883E-06     BCM u10[-]:2.965E-07      
    
    BCM d1 [0]:7.54E-07       BCM d3 [0]:1.827E-07      BCM d10[0]:-8.064E-07     
    BCM d1 [+]:3.275E-07      BCM d3 [+]:9.46E-08       BCM d10[+]:-4.073E-07     
    BCM d1 [-]:4.248E-07      BCM d3 [-]:1.289E-07      BCM d10[-]:-3.979E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2042 at Mon Mar 31 01:32:28 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00340005
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.29398
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 5.17578
    Left Arm Bottom VDC Current : 4.29688
    -----
    Left Arm Q1 momentum : 0.00132211
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.000216
    Left Arm Q2 gauss meter : 0.0008282
    Left Arm Q2 power supply current : 0.00980875
    Left Arm Q2 momentum : 0.00291005
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.36628
    Left Arm D1 momentum : 0.00340005
    Left Arm D1 NMR : 0.156654
    Left Arm Q3 gauss meter : -8.43e-05
    Left Arm Q3 power supply current : -0.000594324
    Left Arm Q3 momentum : -1.28497e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00114528
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -4.16e-05
    Right Arm Q2 power supply current : -0.0158766
    Right Arm Q2 momentum : -3.72431e-05
    Right Arm Q2 gauss meter : 0.0006288
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.318
    Right Arm D1 momentum : 0.294007
    Right Arm D1 NMR : 7.51873
    Right Arm Q3 power supply current : -0.000907922
    Right Arm Q3 momentum : -1.99065e-06
    Right Arm Q3 gauss meter : 0.0001516
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0428964
    Current on Unser monitor : 11.8703
    Current on Upstream bcm : 0.0642396
    Current on Downstream bcm : 0.0215491
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 59.1353
    Hall C Current : 60.72
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.36645
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.29541
    HacL_HPE1313A:0_Ch55 : 23.3887
    HacL_HPE1313A:0_Ch54 : -0.393066
    -----
    Right Arm Collimator : -0.00703125
    HacR_HPE1313A:0_Ch58 : -0.55957
    HacR_HPE1313A:0_Ch55 : 22.2656
    HacR_HPE1313A:0_Ch54 : -0.861328
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 282
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00356948
    HPH H2 loop 3 : 0.00634721
    -----