    User name a-onl

    Log entry time 02:23:22 on March 31, 2008

    Entry number 229160

    keyword=End_of_Run_2050
    ****************************
     Run Number: 2050
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=vme stress test: Vth = 2.50V, monitor rate ~ 292 Hz
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 30324        [+]: 15105        [-]: 14746        
    TIME     : [0]: 4.866 mins  [+]: 2.431 mins  [-]: 2.432 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.49172 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   3.03%      [+]:   4.38%      [-]:   4.41%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :96.6/96.6 Hz   T2[0] : 0.0/1503.5 Hz   T3[0] :13.8/13.8 Hz   T4[0] : 0.0/7.4  Hz   T5[0] : 3.3/3.3  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.6  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :97.8/97.8 Hz   T2[+] : 0.0/1503.9 Hz   T3[+] :13.6/13.6 Hz   T4[+] : 0.0/7.3  Hz   T5[+] : 3.1/3.1  Hz   T6[+] : 0.0/3.7  Hz   T7[+] : 0.0/2.6  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :95.1/95.1 Hz   T2[-] : 0.0/1503.1 Hz   T3[-] :14.1/14.1 Hz   T4[-] : 0.0/7.5  Hz   T5[-] : 3.4/3.4  Hz   T6[-] : 0.0/3.9  Hz   T7[-] : 0.0/3.9  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  28192/28192    T2[0] :      0/438944   T3[0] :   4026/4026     T4[0] :      0/2163     T5[0] :    949/949      T6[0] :      0/1095     T7[0] :      0/766      T8[0] :      4/298964   
    T1[+] :  14273/14273    T2[+] :      0/219405   T3[+] :   1982/1982     T4[+] :      0/1060     T5[+] :    458/458      T6[+] :      0/535      T7[+] :      0/381      T8[+] :      2/149391   
    T1[-] :  13867/13867    T2[-] :      0/219283   T3[-] :   2055/2055     T4[-] :      0/1096     T5[-] :    496/496      T6[-] :      0/562      T7[-] :      0/562      T8[-] :      2/149392   
    
    AVERAGE CURRENT
    BCM x1 : 0.0063 uA  BCM x3 : -0.0237uA  BCM x10: -0.0005uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.167E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.493E+04 ppm     
    BCM d1 :-8.242E+04 ppm     BCM d3 :-1.358E+05 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.851E-06      BCM u3 [0]:-1.391E-05     BCM u10[0]:5.188E-07      
    BCM u1 [+]:1.383E-06      BCM u3 [+]:-6.952E-06     BCM u10[+]:2.55E-07       
    BCM u1 [-]:1.473E-06      BCM u3 [-]:-6.951E-06     BCM u10[-]:2.627E-07      
    
    BCM d1 [0]:8.475E-07      BCM d3 [0]:9.738E-08      BCM d10[0]:-8.25E-07      
    BCM d1 [+]:3.963E-07      BCM d3 [+]:6.13E-08       BCM d10[+]:-4.177E-07     
    BCM d1 [-]:4.674E-07      BCM d3 [-]:8.057E-08      BCM d10[-]:-4.077E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2050 at Mon Mar 31 02:23:16 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00343847
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.29398
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 0.78125
    Left Arm Bottom VDC Current : 2.39258
    -----
    Left Arm Q1 momentum : 0.00129082
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002265
    Left Arm Q2 gauss meter : 0.0007814
    Left Arm Q2 power supply current : 0.00993604
    Left Arm Q2 momentum : 0.00276842
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.36658
    Left Arm D1 momentum : 0.00343847
    Left Arm D1 NMR : 0.156678
    Left Arm Q3 gauss meter : -8.44e-05
    Left Arm Q3 power supply current : -0.000379916
    Left Arm Q3 momentum : -9.4483e-07
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00163309
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -6.85e-05
    Right Arm Q2 power supply current : -0.0160726
    Right Arm Q2 momentum : -3.73462e-05
    Right Arm Q2 gauss meter : 0.000624
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.316
    Right Arm D1 momentum : 0.29398
    Right Arm D1 NMR : 7.51926
    Right Arm Q3 power supply current : -9.71439e-05
    Right Arm Q3 momentum : -2.44136e-07
    Right Arm Q3 gauss meter : 0.0001516
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0426379
    Current on Unser monitor : 10.6574
    Current on Upstream bcm : 0.0637325
    Current on Downstream bcm : 0.0215432
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 59.0604
    Hall C Current : 59.91
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.55086
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.296387
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.391602
    -----
    Right Arm Collimator : -0.00288086
    HacR_HPE1313A:0_Ch58 : -0.560059
    HacR_HPE1313A:0_Ch55 : 22.2656
    HacR_HPE1313A:0_Ch54 : -0.860352
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 282
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.5
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00123869
    HPH H2 loop 3 : 0.011068
    -----