Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:42:09 on March 31, 2008

    Entry number 229166

    keyword=End_of_Run_2053
    ****************************
     Run Number: 2053
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=vme stress test: Vth = 6.00V, monitor rate ~ 55 Hz
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 30397        [+]: 14971        [-]: 14975        
    TIME     : [0]: 4.942 mins  [+]: 2.470 mins  [-]: 2.471 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.63758 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   2.87%      [+]:   4.11%      [-]:   4.47%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :95.6/95.6 Hz   T2[0] : 0.0/1500.9 Hz   T3[0] :13.3/13.3 Hz   T4[0] : 0.0/7.6  Hz   T5[0] : 3.4/3.4  Hz   T6[0] : 0.0/3.7  Hz   T7[0] : 0.0/2.6  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :95.5/95.5 Hz   T2[+] : 0.0/1501.9 Hz   T3[+] :13.3/13.3 Hz   T4[+] : 0.0/7.4  Hz   T5[+] : 3.4/3.4  Hz   T6[+] : 0.0/3.7  Hz   T7[+] : 0.0/2.7  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :95.8/95.8 Hz   T2[-] : 0.0/1499.6 Hz   T3[-] :13.3/13.3 Hz   T4[-] : 0.0/7.8  Hz   T5[-] : 3.4/3.4  Hz   T6[-] : 0.0/3.8  Hz   T7[-] : 0.0/3.8  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  28357/28357    T2[0] :      0/445083   T3[0] :   3948/3948     T4[0] :      0/2247     T5[0] :   1010/1010     T6[0] :      0/1112     T7[0] :      0/777      T8[0] :      4/303663   
    T1[+] :  14148/14148    T2[+] :      0/222578   T3[+] :   1973/1973     T4[+] :      0/1090     T5[+] :    509/509      T6[+] :      0/545      T7[+] :      0/398      T8[+] :      2/151757   
    T1[-] :  14205/14205    T2[-] :      0/222306   T3[-] :   1972/1972     T4[-] :      0/1159     T5[-] :    502/502      T6[-] :      0/565      T7[-] :      0/565      T8[-] :      2/151798   
    
    AVERAGE CURRENT
    BCM x1 : 0.0061 uA  BCM x3 : -0.0242uA  BCM x10: -0.0004uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.055E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.21E+04 ppm     
    BCM d1 :-1.818E+05 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.836E-06      BCM u3 [0]:-1.413E-05     BCM u10[0]:6.041E-07      
    BCM u1 [+]:1.381E-06      BCM u3 [+]:-7.06E-06      BCM u10[+]:2.969E-07      
    BCM u1 [-]:1.469E-06      BCM u3 [-]:-7.064E-06     BCM u10[-]:3.042E-07      
    
    BCM d1 [0]:7.929E-07      BCM d3 [0]:-1.949E-07     BCM d10[0]:-8.231E-07     
    BCM d1 [+]:3.275E-07      BCM d3 [+]:-8.965E-08     BCM d10[+]:-4.155E-07     
    BCM d1 [-]:4.731E-07      BCM d3 [-]:-8.088E-08     BCM d10[-]:-4.068E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2053 at Mon Mar 31 02:42:00 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.0034148
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.294034
    Right Arm arm angle : 0.197
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : -2.09961
    Left Arm Bottom VDC Current : -1.41602
    -----
    Left Arm Q1 momentum : 0.0015881
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002075
    Left Arm Q2 gauss meter : 0.0008535
    Left Arm Q2 power supply current : 0.0101494
    Left Arm Q2 momentum : 0.00308555
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.36939
    Left Arm D1 momentum : 0.0034148
    Left Arm D1 NMR : 0.156659
    Left Arm Q3 gauss meter : -7.7e-05
    Left Arm Q3 power supply current : -0.000571755
    Left Arm Q3 momentum : -1.43614e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00168611
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -4.75e-05
    Right Arm Q2 power supply current : -0.0155549
    Right Arm Q2 momentum : -3.61434e-05
    Right Arm Q2 gauss meter : 0.0006277
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.317
    Right Arm D1 momentum : 0.294007
    Right Arm D1 NMR : 7.51889
    Right Arm Q3 power supply current : -0.000489456
    Right Arm Q3 momentum : -1.23007e-06
    Right Arm Q3 gauss meter : 0.0001514
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0426619
    Current on Unser monitor : 10.6523
    Current on Upstream bcm : 0.0638405
    Current on Downstream bcm : 0.0214769
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00426446
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5717.78
    Delta(E)/E width (MV_AI_DXWID) : 1.56296
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.294922
    HacL_HPE1313A:0_Ch55 : 23.4375
    HacL_HPE1313A:0_Ch54 : -0.392578
    -----
    Right Arm Collimator : -0.00263672
    HacR_HPE1313A:0_Ch58 : -0.55957
    HacR_HPE1313A:0_Ch55 : 22.3145
    HacR_HPE1313A:0_Ch54 : -0.861328
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : -385557
    Target type : -385557
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 282
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.4
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00356948
    HPH H2 loop 3 : 0.00634721
    -----