User name a-onl
Log entry time 12:34:05 on March 31, 2008
Entry number 229182
keyword=End_of_Run_2059
****************************
Run Number: 2059
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=cosmic run
PRESCALE FACTORS:ps1=16777215 ps2=16777215 ps3=1 ps4=16777215 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS : [0]: 845 [+]: 400 [-]: 431
TIME : [0]: 0.900 mins [+]: 0.478 mins [-]: 0.478 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.28568 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: -13.61% [+]: -7.41% [-]: -5.53%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/96.0 Hz T2[0] : 0.0/1313.6 Hz T3[0] :13.8/13.8 Hz T4[0] : 0.0/8.1 Hz T5[0] : 2.2/2.2 Hz T6[0] : 0.0/3.7 Hz T7[0] : 0.0/2.7 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 0.0/96.7 Hz T2[+] : 0.0/1313.3 Hz T3[+] :13.0/13.0 Hz T4[+] : 0.0/8.3 Hz T5[+] : 2.3/2.3 Hz T6[+] : 0.0/3.8 Hz T7[+] : 0.0/2.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 0.0/94.7 Hz T2[-] : 0.0/1320.7 Hz T3[-] :14.2/14.2 Hz T4[-] : 0.0/8.1 Hz T5[-] : 2.2/2.2 Hz T6[-] : 0.0/3.7 Hz T7[-] : 0.0/3.7 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/5181 T2[0] : 0/70906 T3[0] : 743/743 T4[0] : 0/439 T5[0] : 121/121 T6[0] : 0/202 T7[0] : 0/144 T8[0] : 0/55272
T1[+] : 0/2772 T2[+] : 0/37638 T3[+] : 372/372 T4[+] : 0/239 T5[+] : 65/65 T6[+] : 0/109 T7[+] : 0/66 T8[+] : 0/29346
T1[-] : 0/2718 T2[-] : 0/37886 T3[-] : 408/408 T4[-] : 0/231 T5[-] : 64/64 T6[-] : 0/107 T7[-] : 0/107 T8[-] : 0/29375
AVERAGE CURRENT
BCM x1 : 0.0062 uA BCM x3 : -0.0178uA BCM x10: -0.0006uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-2.698E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.027E+04 ppm
BCM d1 :-9.396E+04 ppm BCM d3 :-2.468E+04 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:5.187E-07 BCM u3 [0]:-2.572E-06 BCM u10[0]:9.317E-08
BCM u1 [+]:2.666E-07 BCM u3 [+]:-1.367E-06 BCM u10[+]:4.885E-08
BCM u1 [-]:2.816E-07 BCM u3 [-]:-1.365E-06 BCM u10[-]:4.991E-08
BCM d1 [0]:1.492E-07 BCM d3 [0]:6.517E-07 BCM d10[0]:-1.584E-07
BCM d1 [+]:7.201E-08 BCM d3 [+]:3.411E-07 BCM d10[+]:-8.466E-08
BCM d1 [-]:8.702E-08 BCM d3 [-]:3.587E-07 BCM d10[-]:-8.372E-08
****************************
End-of-run EPICS data for Run Number 2059 at Mon Mar 31 12:33:57 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.299502
Left Arm arm angle : 35.5008
Right Arm D1 momentum : 0.294062
Right Arm arm angle : 101.514
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : 4.6875
Left Arm Bottom VDC Current : 0.830078
-----
Left Arm Q1 momentum : 0.134182
Left Arm Q1 power supply : 99.0158
Left Arm Q1 gauss meter : -0.008267
Left Arm Q2 gauss meter : 0.6287
Left Arm Q2 power supply current : 1596.69
Left Arm Q2 momentum : 3.70806
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 98.5414
Left Arm D1 momentum : 0.299502
Left Arm D1 NMR : 0.156659
Left Arm Q3 gauss meter : -9.65e-05
Left Arm Q3 power supply current : -0.000252023
Left Arm Q3 momentum : -6.33036e-07
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00115589
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -5.1e-05
Right Arm Q2 power supply current : -0.0161095
Right Arm Q2 momentum : -3.70455e-05
Right Arm Q2 gauss meter : 0.0006262
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.315
Right Arm D1 momentum : 0.294034
Right Arm D1 NMR : 7.51944
Right Arm Q3 power supply current : -0.00134133
Right Arm Q3 momentum : -2.41319e-06
Right Arm Q3 gauss meter : 0.0001515
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0429115
Current on Unser monitor : 11.984
Current on Upstream bcm : 0.0642843
Current on Downstream bcm : 0.0215387
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00406784
Hall C Current : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5712.19
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.22168
-----
Right Arm Collimator : -0.00214844
HacR_HPE1313A:0_Ch58 : -0.561035
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.864746
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : 5.85198e+06
Target type : 5.85198e+06
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 282.2
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.5
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.011068
-----