Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 12:44:38 on March 31, 2008
Entry number 229185
keyword=End_of_Run_2060
****************************
Run Number: 2060
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=cosmic run
PRESCALE FACTORS:ps1=16777215 ps2=16777215 ps3=1 ps4=16777215 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS : [0]: 9850 [+]: 4799 [-]: 4916
TIME : [0]: 9.912 mins [+]: 4.918 mins [-]: 4.916 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.78260 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: -20.76% [+]: -19.70% [-]: -19.89%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/95.6 Hz T2[0] : 0.0/1310.3 Hz T3[0] :13.7/13.7 Hz T4[0] : 0.0/7.5 Hz T5[0] : 3.6/3.6 Hz T6[0] : 0.0/3.8 Hz T7[0] : 0.0/2.5 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 0.0/96.2 Hz T2[+] : 0.0/1311.3 Hz T3[+] :13.6/13.6 Hz T4[+] : 0.0/7.5 Hz T5[+] : 3.4/3.4 Hz T6[+] : 0.0/3.7 Hz T7[+] : 0.0/2.5 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 0.0/94.9 Hz T2[-] : 0.0/1309.1 Hz T3[-] :13.9/13.9 Hz T4[-] : 0.0/7.4 Hz T5[-] : 3.7/3.7 Hz T6[-] : 0.0/3.8 Hz T7[-] : 0.0/3.8 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/56837 T2[0] : 0/779247 T3[0] : 8148/8148 T4[0] : 0/4461 T5[0] : 2119/2119 T6[0] : 0/2231 T7[0] : 0/1516 T8[0] : 9/608981
T1[+] : 0/28383 T2[+] : 0/386911 T3[+] : 4005/4005 T4[+] : 0/2216 T5[+] : 1016/1016 T6[+] : 0/1101 T7[+] : 0/752 T8[+] : 4/302151
T1[-] : 0/28001 T2[-] : 0/386146 T3[-] : 4096/4096 T4[-] : 0/2191 T5[-] : 1088/1088 T6[-] : 0/1122 T7[-] : 0/1122 T8[-] : 4/302060
AVERAGE CURRENT
BCM x1 : 0.0064 uA BCM x3 : -0.0178uA BCM x10: -0.0006uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-2.801E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.92E+04 ppm
BCM d1 :-9.991E+04 ppm BCM d3 :-1.77E+04 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:5.84E-06 BCM u3 [0]:-2.834E-05 BCM u10[0]:1.046E-06
BCM u1 [+]:2.818E-06 BCM u3 [+]:-1.406E-05 BCM u10[+]:5.091E-07
BCM u1 [-]:2.98E-06 BCM u3 [-]:-1.406E-05 BCM u10[-]:5.289E-07
BCM d1 [0]:1.723E-06 BCM d3 [0]:7.115E-06 BCM d10[0]:-1.748E-06
BCM d1 [+]:7.679E-07 BCM d3 [+]:3.506E-06 BCM d10[+]:-8.749E-07
BCM d1 [-]:9.381E-07 BCM d3 [-]:3.631E-06 BCM d10[-]:-8.568E-07
****************************
End-of-run EPICS data for Run Number 2060 at Mon Mar 31 12:44:24 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.29953
Left Arm arm angle : 35.5008
Right Arm D1 momentum : 0.294062
Right Arm arm angle : 101.514
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : 5.22461
Left Arm Bottom VDC Current : -0.244141
-----
Left Arm Q1 momentum : 0.134104
Left Arm Q1 power supply : 99.0158
Left Arm Q1 gauss meter : -0.008262
Left Arm Q2 gauss meter : 0.6287
Left Arm Q2 power supply current : 1596.62
Left Arm Q2 momentum : 3.70789
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 98.542
Left Arm D1 momentum : 0.29953
Left Arm D1 NMR : 0.156667
Left Arm Q3 gauss meter : -9.45e-05
Left Arm Q3 power supply current : -3.76154e-05
Left Arm Q3 momentum : -9.4483e-08
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00157476
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -3.29e-05
Right Arm Q2 power supply current : -0.0147415
Right Arm Q2 momentum : -3.53702e-05
Right Arm Q2 gauss meter : 0.0006273
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.316
Right Arm D1 momentum : 0.294089
Right Arm D1 NMR : 7.51956
Right Arm Q3 power supply current : -0.00034374
Right Arm Q3 momentum : -8.63866e-07
Right Arm Q3 gauss meter : 0.0001515
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0430872
Current on Unser monitor : 12.4396
Current on Upstream bcm : 0.0646385
Current on Downstream bcm : 0.021536
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 5.21272
Hall C Current : 5.22
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5712.23
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.167969
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.220215
-----
Right Arm Collimator : -0.00483398
HacR_HPE1313A:0_Ch58 : -0.560547
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.862793
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : 5.85198e+06
Target type : 5.85198e+06
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 282.2
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.5
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.011068
-----