Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 12:45:49 on March 31, 2008

    Entry number 229186

    keyword=End_of_Run_20035
    ****************************
     Run Number: 20035
     End of Run Comment:
    Run_type=Cosmics,target_type=Empty,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,rightarm_p=0.9823,rightarm_theta=25,rightarm_colli=out,comment_text=DAQ and Detector check out
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 2338478      [+]: 1168474      [-]: 1170004      
    TIME     : [0]: 2899.689 mins  [+]: 1452.667 mins  [-]: 1447.429 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =     -2808.52370 seconds
    
    
    DEAD TIME: [0]:   4.05%      [+]:   4.05%      [-]:   4.05%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 7.4/7.4  Hz   T2[0] : 6.6/6.6  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 7.4/7.4  Hz   T2[+] : 6.6/6.6  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 7.4/7.4  Hz   T2[-] : 6.7/6.7  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1281312/1281312  T2[0] :1153389/1153389  T8[0] :   2718/178156917  
    T1[+] : 640957/640957   T2[+] : 575543/575543   T8[+] :   1361/89251882  
    T1[-] : 640336/640336   T2[-] : 577840/577840   T8[-] :   1356/88930048  
    
    AVERAGE CURRENT
    BCM x1 : 0.0057 uA  BCM x3 : 0.0123 uA  BCM x10: -0.0115uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-6.734E+04 ppm     BCM u3 :-5.799E+04 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :-2.107E+05 ppm     BCM d3 :-1.529E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001587       BCM u3 [0]:0.000596       BCM u10[0]:-0.003493      
    BCM u1 [+]:0.0007398      BCM u3 [+]:0.0002807      BCM u10[+]:-0.00175       
    BCM u1 [-]:0.0008435      BCM u3 [-]:0.0003141      BCM u10[-]:-0.001743      
    
    BCM d1 [0]:0.000412       BCM d3 [0]:0.003681       BCM d10[0]:-0.0005081     
    BCM d1 [+]:0.0001623      BCM d3 [+]:0.001913       BCM d10[+]:-0.0002592     
    BCM d1 [-]:0.000248       BCM d3 [-]:0.001965       BCM d10[-]:-0.0002493     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20035 at Mon Mar 31 12:45:42 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.29953
    Left Arm arm angle : 35.5008
    Right Arm D1 momentum : 0.294034
    Right Arm arm angle : 101.514
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 2.19727
    Left Arm Bottom VDC Current : 2.97852
    Left Arm Q1 momentum : 0.134104
    Left Arm Q1 power supply : 99.0158
    Left Arm Q1 gauss meter : -0.008262
    Left Arm Q2 gauss meter : 0.6287
    Left Arm Q2 power supply current : 1596.62
    Left Arm Q2 momentum : 3.7079
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 98.5405
    Left Arm D1 momentum : 0.29953
    Left Arm D1 NMR : 0.156666
    Left Arm Q3 gauss meter : -9.43e-05
    Left Arm Q3 power supply current : -0.000831301
    Left Arm Q3 momentum : -9.63726e-07
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.00126193
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -5.96e-05
    Right Arm Q2 power supply current : -0.0149781
    Right Arm Q2 momentum : -3.55592e-05
    Right Arm Q2 gauss meter : 0.0006272
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.315
    Right Arm D1 momentum : 0.294007
    Right Arm D1 NMR : 7.51957
    Right Arm Q3 power supply current : -0.000623963
    Right Arm Q3 momentum : -1.56811e-06
    Right Arm Q3 gauss meter : 0.0001516
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0430033
    Current on Unser monitor : 12.7847
    Current on Upstream bcm : 0.0646908
    Current on Downstream bcm : 0.0213158
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 5.20253
    Hall C Current : 5.22
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5712.34
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.167969
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.21875
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    Vacuum Pressure : 1.64203e-05
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 5.85198e+06
    Target type : 5.85198e+06
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 282.2
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.5
    HPH He loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00634721