     Run Number: 2062
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=cosmic run  F1/767 test
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=1   ps4=16777215   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 9910         [+]: 4916         [-]: 4844         
    TIME     : [0]: 9.795 mins  [+]: 4.863 mins  [-]: 4.863 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -5.21035 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]: -18.25%      [+]: -16.82%      [-]: -17.71%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/95.5 Hz   T2[0] : 0.0/1299.1 Hz   T3[0] :14.2/14.2 Hz   T4[0] : 0.0/7.3  Hz   T5[0] : 3.6/3.6  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.6  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 0.0/95.6 Hz   T2[+] : 0.0/1299.2 Hz   T3[+] :14.4/14.4 Hz   T4[+] : 0.0/7.3  Hz   T5[+] : 3.6/3.6  Hz   T6[+] : 0.0/3.8  Hz   T7[+] : 0.0/2.7  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 0.0/95.4 Hz   T2[-] : 0.0/1298.6 Hz   T3[-] :14.1/14.1 Hz   T4[-] : 0.0/7.4  Hz   T5[-] : 3.7/3.7  Hz   T6[-] : 0.0/3.7  Hz   T7[-] : 0.0/3.7  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/56123    T2[0] :      0/763516   T3[0] :   8372/8372     T4[0] :      0/4291     T5[0] :   2142/2142     T6[0] :      0/2206     T7[0] :      0/1554     T8[0] :      9/601813   
    T1[+] :      0/27893    T2[+] :      0/379095   T3[+] :   4204/4204     T4[+] :      0/2134     T5[+] :   1054/1054     T6[+] :      0/1095     T7[+] :      0/780      T8[+] :      4/298805   
    T1[-] :      0/27822    T2[-] :      0/378918   T3[-] :   4111/4111     T4[-] :      0/2155     T5[-] :   1076/1076     T6[-] :      0/1089     T7[-] :      0/1089     T8[-] :      4/298782   
    
    AVERAGE CURRENT
    BCM x1 : 0.0056 uA  BCM x3 : -0.0212uA  BCM x10: -0.0005uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.355E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.429E+04 ppm     
    BCM d1 :-1.293E+05 ppm     BCM d3 :-3.925E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:5.342E-06      BCM u3 [0]:-2.8E-05       BCM u10[0]:1.122E-06      
    BCM u1 [+]:2.591E-06      BCM u3 [+]:-1.39E-05      BCM u10[+]:5.499E-07      
    BCM u1 [-]:2.77E-06       BCM u3 [-]:-1.39E-05      BCM u10[-]:5.658E-07      
    
    BCM d1 [0]:1.256E-06      BCM d3 [0]:3.055E-06      BCM d10[0]:-1.746E-06     
    BCM d1 [+]:5.418E-07      BCM d3 [+]:1.553E-06      BCM d10[+]:-8.77E-07      
    BCM d1 [-]:7.027E-07      BCM d3 [-]:1.68E-06       BCM d10[-]:-8.594E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2062 at Mon Mar 31 13:05:02 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.29953
    Left Arm arm angle : 35.5008
    Right Arm D1 momentum : 0.294007
    Right Arm arm angle : 101.514
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : -1.5625
    Left Arm Bottom VDC Current : -0.0976562
    -----
    Left Arm Q1 momentum : 0.134214
    Left Arm Q1 power supply : 99.0158
    Left Arm Q1 gauss meter : -0.008272
    Left Arm Q2 gauss meter : 0.6287
    Left Arm Q2 power supply current : 1596.6
    Left Arm Q2 momentum : 3.70785
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 98.5275
    Left Arm D1 momentum : 0.29953
    Left Arm D1 NMR : 0.156653
    Left Arm Q3 gauss meter : -8.42e-05
    Left Arm Q3 power supply current : 1.88077e-05
    Left Arm Q3 momentum : -4.62967e-07
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00255037
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -5.5e-05
    Right Arm Q2 power supply current : -0.0150114
    Right Arm Q2 momentum : -3.40901e-05
    Right Arm Q2 gauss meter : 0.0006144
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 102.316
    Right Arm D1 momentum : 0.294034
    Right Arm D1 NMR : 7.51949
    Right Arm Q3 power supply current : -0.000937812
    Right Arm Q3 momentum : -2.45075e-06
    Right Arm Q3 gauss meter : 0.0001522
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.043065
    Current on Unser monitor : 11.0852
    Current on Upstream bcm : 0.0646812
    Current on Downstream bcm : 0.0214488
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 4.81797
    Hall C Current : 4.86
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5714.19
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871582
    HacL_HPE1313A:0_Ch58 : -0.165039
    HacL_HPE1313A:0_Ch55 : 23.5352
    HacL_HPE1313A:0_Ch54 : -0.217773
    -----
    Right Arm Collimator : -0.00229492
    HacR_HPE1313A:0_Ch58 : -0.55957
    HacR_HPE1313A:0_Ch55 : 22.168
    HacR_HPE1313A:0_Ch54 : -0.862305
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 5.85198e+06
    Target type : 5.85198e+06
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 282.2
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.5
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00634721
    -----