Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 13:07:45 on March 31, 2008
Entry number 229191
keyword=End_of_Run_2063
****************************
Run Number: 2063
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=cosmic run F1/767 test
PRESCALE FACTORS:ps1=16777215 ps2=16777215 ps3=16777215 ps4=16777215 ps5=65535 ps6=65535 ps7=65535 ps8=1
EVENTS : [0]: 30730 [+]: 15163 [-]: 15118
TIME : [0]: 1.929 mins [+]: 0.986 mins [-]: 0.986 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.41512 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 74.08% [+]: 74.96% [-]: 75.03%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/94.6 Hz T2[0] : 0.0/1302.5 Hz T3[0] : 0.0/14.1 Hz T4[0] : 0.0/7.9 Hz T5[0] : 0.0/3.4 Hz T6[0] : 0.0/3.7 Hz T7[0] : 0.0/2.5 Hz T8[0] :1024.0/1024.0 Hz
T1[+] : 0.0/93.5 Hz T2[+] : 0.0/1299.7 Hz T3[+] : 0.0/14.4 Hz T4[+] : 0.0/7.9 Hz T5[+] : 0.0/3.6 Hz T6[+] : 0.0/3.6 Hz T7[+] : 0.0/2.4 Hz T8[+] :1024.0/1024.0 Hz
T1[-] : 0.0/95.8 Hz T2[-] : 0.0/1303.7 Hz T3[-] : 0.0/13.8 Hz T4[-] : 0.0/7.8 Hz T5[-] : 0.0/3.1 Hz T6[-] : 0.0/3.9 Hz T7[-] : 0.0/3.9 Hz T8[-] :1024.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/10952 T2[0] : 0/150785 T3[0] : 0/1633 T4[0] : 0/918 T5[0] : 0/390 T6[0] : 0/434 T7[0] : 0/294 T8[0] : 118547/118547
T1[+] : 0/5529 T2[+] : 0/76880 T3[+] : 0/853 T4[+] : 0/470 T5[+] : 0/210 T6[+] : 0/213 T7[+] : 0/140 T8[+] : 60572/60572
T1[-] : 0/5666 T2[-] : 0/77099 T3[-] : 0/819 T4[-] : 0/462 T5[-] : 0/184 T6[-] : 0/229 T7[-] : 0/229 T8[-] : 60558/60558
AVERAGE CURRENT
BCM x1 : 0.0056 uA BCM x3 : -0.0195uA BCM x10: -0.0005uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-3.673E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.016E+04 ppm
BCM d1 :-1.938E+05 ppm BCM d3 :-3.449E+04 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:1.061E-06 BCM u3 [0]:-5.518E-06 BCM u10[0]:2.303E-07
BCM u1 [+]:4.933E-07 BCM u3 [+]:-2.821E-06 BCM u10[+]:1.163E-07
BCM u1 [-]:5.308E-07 BCM u3 [-]:-2.817E-06 BCM u10[-]:1.186E-07
BCM d1 [0]:2.366E-07 BCM d3 [0]:1.013E-06 BCM d10[0]:-3.43E-07
BCM d1 [+]:9.791E-08 BCM d3 [+]:5.207E-07 BCM d10[+]:-1.763E-07
BCM d1 [-]:1.449E-07 BCM d3 [-]:5.578E-07 BCM d10[-]:-1.736E-07
****************************
End-of-run EPICS data for Run Number 2063 at Mon Mar 31 13:07:37 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.299502
Left Arm arm angle : 35.5008
Right Arm D1 momentum : 0.294062
Right Arm arm angle : 101.514
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : -1.02539
Left Arm Bottom VDC Current : -1.02539
-----
Left Arm Q1 momentum : 0.134167
Left Arm Q1 power supply : 99.0158
Left Arm Q1 gauss meter : -0.008266
Left Arm Q2 gauss meter : 0.6287
Left Arm Q2 power supply current : 1596.62
Left Arm Q2 momentum : 3.70791
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 98.5279
Left Arm D1 momentum : 0.299502
Left Arm D1 NMR : 0.15665
Left Arm Q3 gauss meter : -9.68e-05
Left Arm Q3 power supply current : -0.000504047
Left Arm Q3 momentum : -1.53062e-06
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 0.00116649
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -4.2e-05
Right Arm Q2 power supply current : -0.0150114
Right Arm Q2 momentum : -3.5121e-05
Right Arm Q2 gauss meter : 0.0006203
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.316
Right Arm D1 momentum : 0.294034
Right Arm D1 NMR : 7.51945
Right Arm Q3 power supply current : -0.000982648
Right Arm Q3 momentum : -2.4977e-06
Right Arm Q3 gauss meter : 0.0001519
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0429061
Current on Unser monitor : 11.7214
Current on Upstream bcm : 0.0644409
Current on Downstream bcm : 0.0213818
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 4.80025
Hall C Current : 4.86
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5714.14
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.164062
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.216797
-----
Right Arm Collimator : -0.00200195
HacR_HPE1313A:0_Ch58 : -0.55957
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.861816
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : 5.85198e+06
Target type : 5.85198e+06
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 282.2
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.5
HPH He loop 1 : 0.0813417
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.011068
-----