Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 13:55:55 on March 31, 2008

    Entry number 229193

    keyword=End_of_Run_2064
    ****************************
     Run Number: 2064
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=cosmic run  F1/767 test
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : [0]: 30647        [+]: 15092        [-]: 15074        
    TIME     : [0]: 1.926 mins  [+]: 0.992 mins  [-]: 0.992 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -5.34655 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  74.10%      [+]:  75.24%      [-]:  75.25%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/94.7 Hz   T2[0] : 0.0/1241.8 Hz   T3[0] : 0.0/14.1 Hz   T4[0] : 0.0/7.5  Hz   T5[0] : 0.0/3.5  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/2.6  Hz   T8[0] :1024.0/1024.0 Hz   
    T1[+] : 0.0/92.9 Hz   T2[+] : 0.0/1241.2 Hz   T3[+] : 0.0/13.8 Hz   T4[+] : 0.0/7.1  Hz   T5[+] : 0.0/3.2  Hz   T6[+] : 0.0/3.6  Hz   T7[+] : 0.0/2.4  Hz   T8[+] :1024.0/1024.0 Hz   
    T1[-] : 0.0/95.9 Hz   T2[-] : 0.0/1240.5 Hz   T3[-] : 0.0/14.4 Hz   T4[-] : 0.0/7.9  Hz   T5[-] : 0.0/4.0  Hz   T6[-] : 0.0/3.9  Hz   T7[-] : 0.0/3.9  Hz   T8[-] :1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/10944    T2[0] :      0/143515   T3[0] :      0/1635     T4[0] :      0/871      T5[0] :      0/408      T6[0] :      0/434      T7[0] :      0/306      T8[0] : 118342/118342   
    T1[+] :      0/5527     T2[+] :      0/73874    T3[+] :      0/821      T4[+] :      0/421      T5[+] :      0/191      T6[+] :      0/216      T7[+] :      0/141      T8[+] :  60947/60947    
    T1[-] :      0/5708     T2[-] :      0/73801    T3[-] :      0/854      T4[-] :      0/468      T5[-] :      0/236      T6[-] :      0/232      T7[-] :      0/232      T8[-] :  60920/60920    
    
    AVERAGE CURRENT
    BCM x1 : 0.0059 uA  BCM x3 : -0.0221uA  BCM x10: -0.0005uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-2.431E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:-1.358E+04 ppm     
    BCM d1 :-2.095E+05 ppm     BCM d3 :-1.772E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:1.093E-06      BCM u3 [0]:-5.506E-06     BCM u10[0]:2.227E-07      
    BCM u1 [+]:5.511E-07      BCM u3 [+]:-2.838E-06     BCM u10[+]:1.132E-07      
    BCM u1 [-]:5.784E-07      BCM u3 [-]:-2.832E-06     BCM u10[-]:1.163E-07      
    
    BCM d1 [0]:2.819E-07      BCM d3 [0]:3.909E-07      BCM d10[0]:-3.374E-07     
    BCM d1 [+]:1.154E-07      BCM d3 [+]:2.328E-07      BCM d10[+]:-1.752E-07     
    BCM d1 [-]:1.764E-07      BCM d3 [-]:2.411E-07      BCM d10[-]:-1.73E-07      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2064 at Mon Mar 31 13:55:47 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0
    Left Arm arm angle : 35.5008
    Right Arm D1 momentum : 0.393917
    Right Arm arm angle : 101.514
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 2.29492
    Left Arm Bottom VDC Current : 3.66211
    -----
    Left Arm Q1 momentum : 1.00022
    Left Arm Q1 power supply : 752.499
    Left Arm Q1 gauss meter : -0.06342
    Left Arm Q2 gauss meter : 0.16982
    Left Arm Q2 power supply current : 430.529
    Left Arm Q2 momentum : 0.999836
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 333.605
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.16981
    Left Arm Q3 gauss meter : -0.0001024
    Left Arm Q3 power supply current : -0.000263308
    Left Arm Q3 momentum : -6.61381e-07
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 1.00011
    Right Arm Q1 power supply : 752.018
    Right Arm Q1 gauss meter : -0.018909
    Right Arm Q2 power supply current : 430.402
    Right Arm Q2 momentum : 1.00008
    Right Arm Q2 gauss meter : 0.22493
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 194.342
    Right Arm D1 momentum : 0.394326
    Right Arm D1 NMR : 7.51934
    Right Arm Q3 power supply current : 397.878
    Right Arm Q3 momentum : 0.999922
    Right Arm Q3 gauss meter : 0.17746
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.0429375
    Current on Unser monitor : 12.4279
    Current on Upstream bcm : 0.0644413
    Current on Downstream bcm : 0.0214337
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 4.80689
    Hall C Current : 4.8
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5714.19
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.165527
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.214844
    -----
    Right Arm Collimator : -0.0019043
    HacR_HPE1313A:0_Ch58 : -0.5625
    HacR_HPE1313A:0_Ch55 : 22.168
    HacR_HPE1313A:0_Ch54 : -0.861328
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 5.85198e+06
    Target type : 5.85198e+06
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 282.2
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.6
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00356948
    HPH H2 loop 3 : 0.00634721
    -----