Run Number: 2065
End of Run Comment:
Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=cosmic run F1/767 test
PRESCALE FACTORS:ps1=16777215 ps2=16777215 ps3=16777215 ps4=16777215 ps5=65535 ps6=65535 ps7=65535 ps8=1
EVENTS : [0]: 30442 [+]: 15009 [-]: 14987
TIME : [0]: 1.913 mins [+]: 0.979 mins [-]: 0.979 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.57077 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 74.09% [+]: 75.04% [-]: 75.08%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/96.6 Hz T2[0] : 0.0/1243.8 Hz T3[0] : 0.0/14.2 Hz T4[0] : 0.0/8.0 Hz T5[0] : 0.0/1.4 Hz T6[0] : 0.0/3.7 Hz T7[0] : 0.0/2.4 Hz T8[0] :1024.0/1024.0 Hz
T1[+] : 0.0/97.8 Hz T2[+] : 0.0/1243.3 Hz T3[+] : 0.0/13.9 Hz T4[+] : 0.0/7.5 Hz T5[+] : 0.0/1.3 Hz T6[+] : 0.0/3.7 Hz T7[+] : 0.0/2.2 Hz T8[+] :1024.0/1024.0 Hz
T1[-] : 0.0/95.5 Hz T2[-] : 0.0/1248.6 Hz T3[-] : 0.0/14.4 Hz T4[-] : 0.0/8.3 Hz T5[-] : 0.0/1.3 Hz T6[-] : 0.0/3.8 Hz T7[-] : 0.0/3.8 Hz T8[-] :1024.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/11090 T2[0] : 0/142752 T3[0] : 0/1627 T4[0] : 0/917 T5[0] : 0/156 T6[0] : 0/430 T7[0] : 0/280 T8[0] : 117523/117523
T1[+] : 0/5745 T2[+] : 0/73019 T3[+] : 0/817 T4[+] : 0/443 T5[+] : 0/77 T6[+] : 0/216 T7[+] : 0/130 T8[+] : 60139/60139
T1[-] : 0/5608 T2[-] : 0/73332 T3[-] : 0/845 T4[-] : 0/486 T5[-] : 0/77 T6[-] : 0/223 T7[-] : 0/223 T8[-] : 60140/60140
AVERAGE CURRENT
BCM x1 : 0.0058 uA BCM x3 : -0.0208uA BCM x10: -0.0005uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-3.075E+04 ppm BCM u3 : 1E+39 ppm BCM u10:-1.18E+04 ppm
BCM d1 :-1.915E+05 ppm BCM d3 :-3.52E+04 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:1.074E-06 BCM u3 [0]:-5.472E-06 BCM u10[0]:2.264E-07
BCM u1 [+]:5.09E-07 BCM u3 [+]:-2.802E-06 BCM u10[+]:1.148E-07
BCM u1 [-]:5.413E-07 BCM u3 [-]:-2.798E-06 BCM u10[-]:1.175E-07
BCM d1 [0]:2.609E-07 BCM d3 [0]:7.012E-07 BCM d10[0]:-3.347E-07
BCM d1 [+]:1.077E-07 BCM d3 [+]:3.661E-07 BCM d10[+]:-1.729E-07
BCM d1 [-]:1.587E-07 BCM d3 [-]:3.928E-07 BCM d10[-]:-1.692E-07
****************************
End-of-run EPICS data for Run Number 2065 at Mon Mar 31 14:00:57 EDT 2008
Wien angle : -26.1977
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0
Left Arm arm angle : 35.5008
Right Arm D1 momentum : 0
Right Arm arm angle : 101.514
HALLA:p : 1193.97
HALLA:dpp : 0
Tiefenbach Hall A energy : 1193.97
Left Arm Top VDC Current : 4.83398
Left Arm Bottom VDC Current : 2.00195
-----
Left Arm Q1 momentum : 1.00022
Left Arm Q1 power supply : 752.499
Left Arm Q1 gauss meter : -0.06341
Left Arm Q2 gauss meter : 0.16978
Left Arm Q2 power supply current : 430.532
Left Arm Q2 momentum : 0.999841
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 333.6
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.160015
Left Arm Q3 gauss meter : -9.07e-05
Left Arm Q3 power supply current : 0.000206885
Left Arm Q3 momentum : 0.00433503
Left Arm Q3 power supply polarity : enabled
-----
Right Arm Q1 momentum : 1.00011
Right Arm Q1 power supply : 752.018
Right Arm Q1 gauss meter : -0.018886
Right Arm Q2 power supply current : 430.402
Right Arm Q2 momentum : 1.00008
Right Arm Q2 gauss meter : 0.22494
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 226.366
Right Arm D1 momentum : 0
Right Arm D1 NMR : 7.51926
Right Arm Q3 power supply current : 397.872
Right Arm Q3 momentum : 0.999908
Right Arm Q3 gauss meter : 0.17745
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
-----
Average current of the two cavities : 0.0430276
Current on Unser monitor : 11.1643
Current on Upstream bcm : 0.0644307
Current on Downstream bcm : 0.0216245
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00296493
Hall C Current : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 298189
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5712.19
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.164551
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.21582
-----
Right Arm Collimator : -0.00473633
HacR_HPE1313A:0_Ch58 : -0.560059
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.862305
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -606.46
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
-----
Target : Home
fan frequency loop 1 : 0
fan frequency loop 3 : 0
Encoder position : 5.85198e+06
Target type : 5.85198e+06
temperature loop 1(1) : 4
temperature loop 1(3) : 119.99
Heat exchange He : 282.2
temperature loop 3(1) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 295.5
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.011068
-----