Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:38:32 on March 31, 2008

    Entry number 229209

    keyword=End_of_Run_2071
    ****************************
     Run Number: 2071
     End of Run Comment:
    Run_type=Test,target_type=Empty,beam_e0=0.956,beam_raster=on,leftarm_p=0.9823,leftarm_theta=25,leftarm_colli=out,bbarm_i=0.0,bbarm_theta=30,bbarm_colli=out,comment_text=cosmic run  F1/767 test
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=1   
    
    EVENTS   : [0]: 10946        [+]: 5398         [-]: 5393         
    TIME     : [0]: 0.656 mins  [+]: 0.357 mins  [-]: 0.356 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.10073 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  72.85%      [+]:  75.37%      [-]:  75.38%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/93.6 Hz   T2[0] : 0.0/1323.9 Hz   T3[0] : 0.0/13.5 Hz   T4[0] : 0.0/7.2  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/3.7  Hz   T7[0] : 0.0/2.7  Hz   T8[0] :1024.0/1024.0 Hz   
    T1[+] : 0.0/92.7 Hz   T2[+] : 0.0/1322.9 Hz   T3[+] : 0.0/12.9 Hz   T4[+] : 0.0/7.1  Hz   T5[+] : 0.0/0.0  Hz   T6[+] : 0.0/3.7  Hz   T7[+] : 0.0/2.2  Hz   T8[+] :1024.0/1024.0 Hz   
    T1[-] : 0.0/93.2 Hz   T2[-] : 0.0/1323.4 Hz   T3[-] : 0.0/14.4 Hz   T4[-] : 0.0/6.5  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/3.7  Hz   T7[-] : 0.0/3.7  Hz   T8[-] :1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/3686     T2[0] :      0/52133    T3[0] :      0/533      T4[0] :      0/282      T5[0] :      0/0        T6[0] :      0/147      T7[0] :      0/107      T8[0] :  40324/40324    
    T1[+] :      0/1985     T2[+] :      0/28318    T3[+] :      0/276      T4[+] :      0/151      T5[+] :      0/0        T6[+] :      0/80       T7[+] :      0/47       T8[+] :  21919/21919    
    T1[-] :      0/1994     T2[-] :      0/28307    T3[-] :      0/308      T4[-] :      0/140      T5[-] :      0/0        T6[-] :      0/80       T7[-] :      0/80       T8[-] :  21903/21903    
    
    AVERAGE CURRENT
    BCM x1 : 0.0056 uA  BCM x3 : -0.0229uA  BCM x10: -0.0005uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-3.653E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:    -9470 ppm     
    BCM d1 :-2.568E+05 ppm     BCM d3 :-1.392E+05 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:3.537E-07      BCM u3 [0]:-1.876E-06     BCM u10[0]:7.246E-08      
    BCM u1 [+]:1.891E-07      BCM u3 [+]:-1.021E-06     BCM u10[+]:3.925E-08      
    BCM u1 [-]:2.033E-07      BCM u3 [-]:-1.018E-06     BCM u10[-]:3.997E-08      
    
    BCM d1 [0]:8.626E-08      BCM d3 [0]:7.379E-08      BCM d10[0]:-1.152E-07     
    BCM d1 [+]:3.254E-08      BCM d3 [+]:4.043E-08      BCM d10[+]:-6.388E-08     
    BCM d1 [-]:5.499E-08      BCM d3 [-]:5.347E-08      BCM d10[-]:-6.149E-08     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2071 at Mon Mar 31 14:38:22 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.999976
    Left Arm arm angle : 35.5008
    Right Arm D1 momentum : 0.875935
    Right Arm arm angle : 101.514
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : 0.0976562
    Left Arm Bottom VDC Current : 4.05273
    -----
    Left Arm Q1 momentum : 0.999938
    Left Arm Q1 power supply : 752.338
    Left Arm Q1 gauss meter : -0.06352
    Left Arm Q2 gauss meter : 0.1699
    Left Arm Q2 power supply current : 430.643
    Left Arm Q2 momentum : 1.0001
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 332.025
    Left Arm D1 momentum : 0.999976
    Left Arm D1 NMR : 0.370249
    Left Arm Q3 gauss meter : -0.5903
    Left Arm Q3 power supply current : 1137.36
    Left Arm Q3 momentum : 2.89774
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.999826
    Right Arm Q1 power supply : 751.804
    Right Arm Q1 gauss meter : -0.018909
    Right Arm Q2 power supply current : 430.414
    Right Arm Q2 momentum : 1.00011
    Right Arm Q2 gauss meter : 0.225
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 342.768
    Right Arm D1 momentum : 0.876203
    Right Arm D1 NMR : 0.325447
    Right Arm Q3 power supply current : 398.004
    Right Arm Q3 momentum : 1.00024
    Right Arm Q3 gauss meter : 0.17755
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    -----
    Average current of the two cavities : 0.043361
    Current on Unser monitor : 11.6751
    Current on Upstream bcm : 0.0652212
    Current on Downstream bcm : 0.0215008
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00276958
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5712.19
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.162598
    HacL_HPE1313A:0_Ch55 : 23.4375
    HacL_HPE1313A:0_Ch54 : -0.215332
    -----
    Right Arm Collimator : -0.00166016
    HacR_HPE1313A:0_Ch58 : -0.55957
    HacR_HPE1313A:0_Ch55 : 22.2168
    HacR_HPE1313A:0_Ch54 : -0.862793
    -----
    Wien angle : -26.1977
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -606.46
    Wien field : 17.378
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Home
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 5.85198e+06
    Target type : 5.85198e+06
    temperature loop 1(1) : 4
    temperature loop 1(3) : 119.99
    Heat exchange He : 282.2
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 295.5
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00123869
    HPH H2 loop 3 : 0.00634721
    -----