    keyword=End_of_Run_20036
    ****************************
     Run Number: 20036
     End of Run Comment:
    Run_type=Cosmics,target_type=Empty,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,rightarm_p=0.9823,rightarm_theta=25,rightarm_colli=out,comment_text=DAQ and Detector check out
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 293149       [+]: 146924       [-]: 146225       
    TIME     : [0]: 362.653 mins  [+]: 181.629 mins  [-]: 181.046 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =      -349.44260 seconds
    
    
    DEAD TIME: [0]:   4.04%      [+]:   4.14%      [-]:   3.93%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 7.4/7.4  Hz   T2[0] : 6.6/6.6  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 7.4/7.4  Hz   T2[+] : 6.6/6.6  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 7.4/7.4  Hz   T2[-] : 6.6/6.6  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 160902/160902   T2[0] : 144272/144272   T8[0] :    339/22281421  
    T1[+] :  80647/80647    T2[+] :  72460/72460    T8[+] :    170/11159281  
    T1[-] :  80250/80250    T2[-] :  71797/71797    T8[-] :    169/11123446  
    
    AVERAGE CURRENT
    BCM x1 : 0.0046 uA  BCM x3 : 0.0111 uA  BCM x10: -0.0115uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-7.323E+04 ppm     BCM u3 :-6.029E+04 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :-3.882E+05 ppm     BCM d3 :-1.567E+04 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0001741      BCM u3 [0]:6.585E-05      BCM u10[0]:-0.0004368     
    BCM u1 [+]:8.075E-05      BCM u3 [+]:3.097E-05      BCM u10[+]:-0.0002188     
    BCM u1 [-]:9.321E-05      BCM u3 [-]:3.483E-05      BCM u10[-]:-0.0002181     
    
    BCM d1 [0]:2.713E-05      BCM d3 [0]:0.000418       BCM d10[0]:-6.428E-05     
    BCM d1 [+]:8.293E-06      BCM d3 [+]:0.0002125      BCM d10[+]:-3.273E-05     
    BCM d1 [-]:1.876E-05      BCM d3 [-]:0.0002186      BCM d10[-]:-3.157E-05     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20036 at Mon Mar 31 20:40:14 EDT 2008
    
    Wien angle : -26.1977
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.969319
    Left Arm arm angle : 35.5008
    Right Arm D1 momentum : 0.497527
    Right Arm arm angle : 101.514
    HALLA:p : 1193.97
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1193.97
    Left Arm Top VDC Current : -2.00195
    Left Arm Bottom VDC Current : 4.44336
    Left Arm Q1 momentum : 0.969342
    Left Arm Q1 power supply : 729.267
    Left Arm Q1 gauss meter : -0.06147
    Left Arm Q2 gauss meter : 0.16515
    Left Arm Q2 power supply current : 417.399
    Left Arm Q2 momentum : 0.969344
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 322.441
    Left Arm D1 momentum : 0.969319
    Left Arm D1 NMR : 0.358912
    Left Arm Q3 gauss meter : -0.19568
    Left Arm Q3 power supply current : 385.98
    Left Arm Q3 momentum : 0.96951
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.473527
    Right Arm Q1 power supply : 356.062
    Right Arm Q1 gauss meter : -0.009011
    Right Arm Q2 power supply current : 203.923
    Right Arm Q2 momentum : 0.473835
    Right Arm Q2 gauss meter : 0.10729
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 182.093
    Right Arm D1 momentum : 0.49738
    Right Arm D1 NMR : 0.184572
    Right Arm Q3 power supply current : 188.41
    Right Arm Q3 momentum : 0.4735
    Right Arm Q3 gauss meter : 0.08436
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.04296
    Current on Unser monitor : 11.4387
    Current on Upstream bcm : 0.0646854
    Current on Downstream bcm : 0.0214045
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 1.00592
    Hall C Current : 0.96
    MBSY1c magnet current (amp) : 49.5203
    MBSY1c Bdl : 298189
    Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1193.97
    Hall C energy (hallc_MeV) : 5714.19
    Delta(E)/E width (MV_AI_DXWID) : 0.821997
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.166992
    HacL_HPE1313A:0_Ch55 : 23.3887
    HacL_HPE1313A:0_Ch54 : -0.216309
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.745342
    SLI vert. size mm : 0
    SLI y position : 1.39718
    -----
    Target : Clear
    Vacuum Pressure : 2.64698e-07
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 19
    Target type : 19
    temperature loop 1(1) : 19.98
    temperature loop 1(3) : 20.3
    Heat exchange He : 22.4
    temperature loop 3(1) : 99.99
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 288.5
    HPH He loop 1 : 56.2574
    HPH H2 loop 3 : 0.011068