Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 21:15:28 on March 31, 2008
Entry number 229240
keyword=Start_Run_20037,Run_type=Cosmics,target_type=Empty,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,rightarm_p=0.9823,rightarm_theta=25,rightarm_colli=out,comment_text=DAQ and Detector check out
Run Timestamp: Mon Mar 31 21:13:29 EDT 2008
Beginning-of-run EPICS data for Run Number 20037 at Mon Mar 31 21:14:32 EDT 2008
Run_type=Cosmics
target_type=Empty
beam_e0=0.9574
beam_raster=on
beam_halfwaveplate=out
rightarm_p=0.9823
rightarm_theta=25
rightarm_colli=out
comment_text=DAQ and Detector check out
; RIGHT SPECTROMETER on adaql1/adev account.
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; Default factor is (2^24)-1 = 16.7M for ps1-4 and (2^16)-1 = 65K for ps5-8.
; T1 = main trigger S1.and.S2
; T2 = efficiency trigger (recommend to keep ~5 Hz)
; T8 = 1024 Hz pulser
; All other prescales should be maxed out.
ps1=1,ps2=1,ps3=16777215,ps4=16777215,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 momentum : 0.969342
Left Arm Q1 power supply : 729.267
Left Arm Q1 gauss meter : -0.06146
Left Arm Q2 power supply current : 417.398
Left Arm Q2 momentum : 0.969342
Left Arm Q2 gauss meter : 0.16515
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 322.43
Left Arm D1 momentum : 0.969294
Left Arm D1 NMR : 0.358903
Left Arm Q3 power supply current : 385.98
Left Arm Q3 momentum : 0.96951
Left Arm Q3 gauss meter : -0.19569
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.3464
Right Arm Q1 momentum : 0.473456
Right Arm Q1 power supply : 356.062
Right Arm Q1 gauss meter : -0.008989
Right Arm Q2 power supply current : 203.923
Right Arm Q2 momentum : 0.473835
Right Arm Q2 gauss meter : 0.10728
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 163.061
Right Arm D1 momentum : 0.473357
Right Arm D1 NMR : 0.175657
Right Arm Q3 power supply current : 188.41
Right Arm Q3 momentum : 0.473499
Right Arm Q3 gauss meter : 0.08436
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.17378
Left Arm Top VDC Current : 1.07422
Left Arm Bottom VDC Current : -0.0976562
Left Arm Top VDC voltage : 3.98535
Left Arm Bottom VDC voltage : 3.99658
Right Arm Top VDC voltage : 4.00244
Right Arm Bottom VDC voltage : 4.00928
-----
Average current of the two cavities : 0.0428782
Current on Unser monitor : 11.4877
Current on Upstream bcm : 0.0643988
Current on Downstream bcm : 0.0214994
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 1.03649
Hall C Current : 1.02
Hall A momentum (Tiefenbach) (HALLA:p) : 1193.97
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1193.97
Hall C energy (hallc_MeV) : 5714.18
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c magnet current (amp) : 49.5203
MBSY1c Bdl : 298189
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.165527
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.216797
Left Arm Angle Floor Angle : 35.5
Left Arm Angle Vernier : 31.2
Left Arm Scattering Angle : 35.5008
Right Arm Arm Collimator : -0.00439453
HacR_HPE1313A:0_Ch58 : -0.564453
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.865234
Right Arm Angle Floor Angle : 101.5
Right Arm Angle Vernier : -31.8
Right Arm Scattering Angle : 101.514
-----
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : -26.1977
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 17.378
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
Target : Clear
Vacuum Pressure : 2.57633e-07
fan frequency loop 1 : 59.5
fan frequency loop 2 : 47.5
fan frequency loop 3 : 0
Encoder position : 19
Target type : 19
temperature loop 1(1) : 20.03
temperature loop 1(2) : 20.02
temperature loop 1(3) : 20.34
Heat exchange He : 22.5
temperature loop 3(1) : 99.99
temperature loop 3(2) : 99.99
temperature loop 3(3) : 99.99
Heat exchange H2 : 287.3
pressure loop He : 17.7168
pressure loop H2 before : 23.1113
pressure loop H2 return : 23.5782
HPH He loop 1 : 61.9367
HPH He loop 2 : 41.5514
HPH H2 loop 3 : 0.011068
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.745342
SLI vert. size mm : 0
SLI y position : 1.39718
Right S2 HV
S2 Slot1 ch0 : -2275
S2 Slot1 ch1 : -2120.7
S2 Slot1 ch2 : -2275.3
S2 Slot1 ch3 : -2050.6
S2 Slot1 ch4 : -2175.8
S2 Slot1 ch5 : -1991
S2 Slot1 ch6 : -2401.6
S2 Slot1 ch7 : -2451.9
S2 Slot1 ch8 : -2250.8
S2 Slot1 ch9 : -2451.9
S2 Slot1 ch10 : -2266.5
S2 Slot1 ch11 : -2001.6
-----
Right S1 HV
S1 Slot2 ch0 : -1720.9
S1 Slot2 ch1 : -1901.6
S1 Slot2 ch2 : -1750.7
S1 Slot2 ch3 : -1746.2
S1 Slot2 ch4 : -1697.7
S1 Slot2 ch5 : -2051
S1 Slot2 ch6 : -1812.1
S1 Slot2 ch7 : -1976.6
S1 Slot2 ch8 : -1827
S1 Slot2 ch9 : -1866.7
S1 Slot2 ch10 : -1876.6
S1 Slot2 ch11 : -1947.2
-----
Right Preshower HV
PS Slot4 ch0 : -976.2
PS Slot4 ch1 : -975.6
PS Slot4 ch2 : -975.9
PS Slot4 ch3 : -1001.5
PS Slot4 ch4 : -989
PS Slot4 ch5 : -988.7
PS Slot4 ch6 : -975.4
PS Slot4 ch7 : -960.9
PS Slot4 ch8 : -975.7
PS Slot4 ch9 : -977.1
PS Slot4 ch10 : -977
PS Slot4 ch11 : -976.7
PS Slot5 ch0 : -975.5
PS Slot5 ch1 : -937
PS Slot5 ch2 : -936.7
PS Slot5 ch3 : -975.5
PS Slot5 ch4 : -975.9
PS Slot5 ch5 : -975.3
PS Slot5 ch6 : -976.5
PS Slot5 ch7 : -976.2
PS Slot5 ch8 : -1061.8
PS Slot5 ch9 : -1002.5
PS Slot5 ch10 : -976.2
PS Slot5 ch11 : -976.6
PS Slot7 ch0 : -1098.1
PS Slot7 ch1 : -1008.1
PS Slot7 ch2 : -1001.9
PS Slot7 ch3 : -987.9
PS Slot7 ch4 : -989.5
PS Slot7 ch5 : -989.1
PS Slot7 ch6 : -989.5
PS Slot7 ch7 : -975.4
PS Slot7 ch8 : -975.8
PS Slot7 ch9 : -976.5
PS Slot7 ch10 : -989.4
PS Slot7 ch11 : -989.9
PS Slot8 ch0 : -811.2
PS Slot8 ch1 : -976.4
PS Slot8 ch2 : -975.2
PS Slot8 ch3 : -976
PS Slot8 ch4 : -1126.6
PS Slot8 ch5 : -1002.5
PS Slot8 ch6 : -989.9
PS Slot8 ch7 : -1096.4
PS Slot8 ch8 : -976.5
PS Slot8 ch9 : -1098.4
PS Slot8 ch10 : -975
PS Slot8 ch11 : -974.7
-----
Right Cerenkov HV
GCER Slot14 ch0 : -2466.6
GCER Slot14 ch1 : -2571.6
GCER Slot14 ch2 : -2586.2
GCER Slot14 ch3 : -2458.2
GCER Slot14 ch4 : -2525.1
GCER Slot14 ch5 : -2400.1
GCER Slot14 ch6 : -2546.3
GCER Slot14 ch7 : -2501.2
GCER Slot14 ch8 : -2501.5
GCER Slot14 ch9 : -2399.9
GCER Slot14 ch10 : -14.2
GCER Slot14 ch11 : -24.6
-----
Right Shower HV
SH Slot1 ch0 : -699.3
SH Slot1 ch1 : -698.9
SH Slot1 ch2 : -699.4
SH Slot1 ch3 : -700.4
SH Slot1 ch4 : -700
SH Slot1 ch5 : -700.3
SH Slot1 ch6 : -699.5
SH Slot1 ch7 : -700.5
SH Slot1 ch8 : -700.5
SH Slot1 ch9 : -700.6
SH Slot1 ch10 : -699.7
SH Slot1 ch11 : -700.4
SH Slot2 ch0 : -700.7
SH Slot2 ch1 : -700.2
SH Slot2 ch2 : -699.9
SH Slot2 ch3 : -9.3
SH Slot2 ch4 : -700.9
SH Slot2 ch5 : -700.5
SH Slot2 ch6 : -691.1
SH Slot2 ch7 : -634.4
SH Slot2 ch8 : -666.6
SH Slot2 ch9 : -635.1
SH Slot2 ch10 : -634
SH Slot2 ch11 : -666.1
SH Slot4 ch0 : -662
SH Slot4 ch1 : -658.8
SH Slot4 ch2 : -664
SH Slot4 ch3 : -705.2
SH Slot4 ch4 : -691
SH Slot4 ch5 : -665.5
SH Slot4 ch6 : -826.4
SH Slot4 ch7 : -7.9
SH Slot4 ch8 : -700.2
SH Slot4 ch9 : -683.5
SH Slot4 ch10 : -687.6
SH Slot4 ch11 : -633.3
SH Slot5 ch0 : -644.5
SH Slot5 ch1 : -654.9
SH Slot5 ch2 : -595.4
SH Slot5 ch3 : -608.6
SH Slot5 ch4 : -673.5
SH Slot5 ch5 : -602.8
SH Slot5 ch6 : -655.8
SH Slot5 ch7 : -650.9
SH Slot5 ch8 : -690.8
SH Slot5 ch9 : -679.4
SH Slot5 ch10 : -750.3
SH Slot5 ch11 : -9.3
SH Slot7 ch0 : -759.1
SH Slot7 ch1 : -698.7
SH Slot7 ch2 : -679
SH Slot7 ch3 : -685.3
SH Slot7 ch4 : -671.8
SH Slot7 ch5 : -668.8
SH Slot7 ch6 : -657.4
SH Slot7 ch7 : -650.8
SH Slot7 ch8 : -676.1
SH Slot7 ch9 : -694
SH Slot7 ch10 : -688.2
SH Slot7 ch11 : -704
SH Slot8 ch0 : -674.1
SH Slot8 ch1 : -722.1
SH Slot8 ch2 : -730.8
SH Slot8 ch3 : -4
SH Slot8 ch4 : -730.9
SH Slot8 ch5 : -705.1
SH Slot8 ch6 : -697.2
SH Slot8 ch7 : -717.3
SH Slot8 ch8 : -668.1
SH Slot8 ch9 : -677.2
SH Slot8 ch10 : -692.6
SH Slot8 ch11 : -672.3
SH Slot10 ch0 : -675.3
SH Slot10 ch1 : -702.7
SH Slot10 ch2 : -697.7
SH Slot10 ch3 : -717
SH Slot10 ch4 : -750.6
SH Slot10 ch5 : -851
SH Slot10 ch6 : -751
SH Slot10 ch7 : -6
SH Slot10 ch8 : -9.9
SH Slot10 ch9 : -13.6
SH Slot10 ch10 : -16.3
SH Slot10 ch11 : -14.1
-----