Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 08:32:20 on April 29, 2008
Entry number 235759
keyword=End_of_Run_4372
****************************
Run Number: 4372
End of Run Comment:
Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.1923,beam_raster=off,leftarm_p=1.007,leftarm_theta=12.5,leftarm_colli=out,bbarm_i=390,bbarm_theta=48,bbarm_colli=out,comment_text=Production Kinematic E
PRESCALE FACTORS:ps1=43900 ps2=78000 ps3=4500 ps4=130 ps5=1 ps6=1 ps7=3700 ps8=100
EVENTS : [0]: 1003935 [+]: 495682 [-]: 493388
TIME : [0]: 7.602 mins [+]: 3.778 mins [-]: 3.777 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -4.43157 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 20.25% [+]: 20.93% [-]: 20.94%
TRIGGER RATES: PRES/REAL
T1[0] :10.0/439642.0 Hz T2[0] :10.0/781293.4 Hz T3[0] :10.2/45702.8 Hz T4[0] :10.0/1295.8 Hz T5[0] :1631.6/1631.6 Hz T6[0] :2700.7/2700.7 Hz T7[0] :10.2/37749.3 Hz T8[0] :10.2/1024.0 Hz
T1[+] :10.0/439935.8 Hz T2[+] :10.0/781809.1 Hz T3[+] :10.2/45736.6 Hz T4[+] :10.0/1295.8 Hz T5[+] :1638.5/1638.5 Hz T6[+] :2706.6/2706.6 Hz T7[+] :10.2/37775.8 Hz T8[+] :10.2/1024.0 Hz
T1[-] :10.0/439377.8 Hz T2[-] :10.0/780868.9 Hz T3[-] :10.1/45670.4 Hz T4[-] :10.0/1297.1 Hz T5[-] :1624.8/1624.8 Hz T6[-] :2694.2/2694.2 Hz T7[-] :10.2/37724.7 Hz T8[-] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 4567/200531704 T2[0] : 4568/356367447 T3[0] : 4632/20846167 T4[0] : 4546/591037 T5[0] : 744230/744230 T6[0] :1231843/1231843 T7[0] : 4653/17218420 T8[0] : 4670/467072
T1[+] : 2271/99714638 T2[+] : 2271/177202679 T3[+] : 2303/10366531 T4[+] : 2259/293698 T5[+] : 371372/371372 T6[+] : 613467/613467 T7[+] : 2314/8562169 T8[+] : 2320/232097
T1[-] : 2268/99583442 T2[-] : 2268/176981195 T3[-] : 2300/10351031 T4[-] : 2261/293974 T5[-] : 368247/368247 T6[-] : 610624/610624 T7[-] : 2310/8550181 T8[-] : 2320/232086
AVERAGE CURRENT
BCM x1 : 2.9660 uA BCM x3 : 2.9724 uA BCM x10: 2.9980 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 589.1 ppm BCM u3 : 648.8 ppm BCM u10: 689.5 ppm
BCM d1 : 550.3 ppm BCM d3 : 646.5 ppm BCM d10: 688.4 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001346 BCM u3 [0]:0.001348 BCM u10[0]:0.001359
BCM u1 [+]:0.000669 BCM u3 [+]:0.0006703 BCM u10[+]:0.0006757
BCM u1 [-]:0.0006682 BCM u3 [-]:0.0006694 BCM u10[-]:0.0006747
BCM d1 [0]:0.00136 BCM d3 [0]:0.001364 BCM d10[0]:0.001376
BCM d1 [+]:0.0006764 BCM d3 [+]:0.0006781 BCM d10[+]:0.0006844
BCM d1 [-]:0.0006756 BCM d3 [-]:0.0006772 BCM d10[-]:0.0006834
****************************
End-of-run EPICS data for Run Number 4372 at Tue Apr 29 08:32:16 EDT 2008
Wien angle : -40.2035
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 1.00699
Left Arm arm angle : 12.4507
Right Arm D1 momentum : 0.459612
Right Arm arm angle : 104.998
HALLA:p : 1192.38
HALLA:dpp : 0
Tiefenbach Hall A energy : 1192.38
Left Arm Top VDC Current : -5.85938
Left Arm Bottom VDC Current : -4.05273
-----
Left Arm Q1 momentum : 1.00711
Left Arm Q1 power supply : 757.679
Left Arm Q1 gauss meter : -0.06395
Left Arm Q2 gauss meter : 0.17151
Left Arm Q2 power supply current : 433.611
Left Arm Q2 momentum : 1.00699
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 334.436
Left Arm D1 momentum : 1.00699
Left Arm D1 NMR : 0.372841
Left Arm Q3 gauss meter : -0.2035
Left Arm Q3 power supply current : 400.82
Left Arm Q3 momentum : 1.00679
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.459677
Right Arm Q1 power supply : 345.647
Right Arm Q1 gauss meter : -0.008732
Right Arm Q2 power supply current : 197.778
Right Arm Q2 momentum : 0.459555
Right Arm Q2 gauss meter : 0.10406
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 158.186
Right Arm D1 momentum : 0.459612
Right Arm D1 NMR : 0.170556
Right Arm Q3 power supply current : 182.887
Right Arm Q3 momentum : 0.459621
Right Arm Q3 gauss meter : 0.08185
Right Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 390
BigBite magnet current readback : 388.1
BigBite Gaussmeter readback : -0.3177
-----
Average current of the two cavities : 3.01439
Current on Unser monitor : 14.324
Current on Upstream bcm : 2.96165
Current on Downstream bcm : 3.06712
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 80.8531
Hall C Current : 80.19
MBSY1c magnet current (amp) : 49.4539
MBSY1c Bdl : 297794
Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 1193.56
Hall A energy (halla_MeV) : 1192.38
Hall C energy (hallc_MeV) : 5710.71
Delta(E)/E width (MV_AI_DXWID) : 1.27184
IPM1C12.XPOS : -0.00957
IPM1H04A.XPOS : -0.774716
IPM1H04A.YPOS : 0.771266
IPM1H04B.XPOS : -1.28868
IPM1H04B.YPOS : 1.69386
-----
Left Arm Collimator : 0.871289
HacL_HPE1313A:0_Ch58 : -0.248047
HacL_HPE1313A:0_Ch55 : 24.2188
HacL_HPE1313A:0_Ch54 : 0.174316
-----
Right Arm Collimator : -0.00864258
HacR_HPE1313A:0_Ch58 : -0.575195
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.833496
-----
Wien angle : -40.2035
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -934.12
Wien field : 26.736
Laser attenuation Hall A : 96
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Cycle Rate Set : 30 Hz
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.41491
SLI vert. size mm : 0
SLI y position : 2.38873
-----
Target : L1 6cm
fan frequency loop 1 : 31
fan frequency loop 2 : 14
Encoder position : 3.13948e+07
Target type : 3.13948e+07
temperature loop 1(1) : 20
temperature loop 1(2) : 19.99
temperature loop 1(3) : 20.3
Heat exchange LH : 22.4
temperature loop 2(1) : 23.57
temperature loop 2(2) : 95.14
temperature loop 2(3) : 119.99
Heat exchange H2 : 22.4
Heat exchange D2 : 24.1
HPH H2 loop 1 : 35.6379
HPH D2 loop 2 : 0.0118473
-----