     Run Number: 4374
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.1923,beam_raster=off,leftarm_p=1.007,leftarm_theta=12.5,leftarm_colli=out,bbarm_i=390,bbarm_theta=48,bbarm_colli=out,comment_text=Production Kinematic E
     
    
    PRESCALE FACTORS:ps1=43900   ps2=78000   ps3=4500   ps4=130   ps5=1   ps6=1   ps7=3700   ps8=100   
    
    EVENTS   : [0]: 1005215      [+]: 495069       [-]: 495229       
    TIME     : [0]: 8.015 mins  [+]: 3.982 mins  [-]: 3.984 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.69437 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  19.74%      [+]:  20.48%      [-]:  20.41%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 9.6/420461.9 Hz   T2[0] : 9.6/747460.1 Hz   T3[0] : 9.7/43706.9 Hz   T4[0] : 9.4/1227.1 Hz   T5[0] :1539.7/1539.7 Hz   T6[0] :2547.2/2547.2 Hz   T7[0] : 9.8/36108.6 Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] : 9.6/420869.7 Hz   T2[+] : 9.6/748203.7 Hz   T3[+] : 9.7/43737.1 Hz   T4[+] : 9.4/1228.1 Hz   T5[+] :1539.0/1539.0 Hz   T6[+] :2548.4/2548.4 Hz   T7[+] : 9.8/36128.0 Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] : 9.6/420216.6 Hz   T2[-] : 9.6/747045.6 Hz   T3[-] : 9.7/43690.3 Hz   T4[-] : 9.4/1226.9 Hz   T5[-] :1540.5/1540.5 Hz   T6[-] :2546.1/2546.1 Hz   T7[-] : 9.8/36101.6 Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   4606/202209328  T2[0] :   4608/359469926  T3[0] :   4671/21019611  T4[0] :   4539/590160   T5[0] : 740482/740482   T6[0] :1224996/1224996  T7[0] :   4693/17365431  T8[0] :   4924/492464   
    T1[+] :   2290/100557442  T2[+] :   2291/178766615  T3[+] :   2322/10450016  T4[+] :   2257/293426   T5[+] : 367716/367716   T6[+] : 608889/608889   T7[+] :   2332/8631981  T8[+] :   2446/244662   
    T1[-] :   2288/100449008  T2[-] :   2289/178574544  T3[-] :   2320/10443777  T4[-] :   2255/293276   T5[-] : 368247/368247   T6[-] : 608614/608614   T7[-] :   2332/8629772  T8[-] :   2447/244778   
    
    AVERAGE CURRENT
    BCM x1 : 2.8263 uA  BCM x3 : 2.8327 uA  BCM x10: 2.8572 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :      642 ppm     BCM u3 :    732.8 ppm     BCM u10:    767.5 ppm     
    BCM d1 :    639.4 ppm     BCM d3 :    719.8 ppm     BCM d10:    763.9 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001352       BCM u3 [0]:0.001354       BCM u10[0]:0.001365       
    BCM u1 [+]:0.0006722      BCM u3 [+]:0.0006735      BCM u10[+]:0.000679       
    BCM u1 [-]:0.0006717      BCM u3 [-]:0.0006729      BCM u10[-]:0.0006783      
    
    BCM d1 [0]:0.001367       BCM d3 [0]:0.00137        BCM d10[0]:0.001383       
    BCM d1 [+]:0.0006796      BCM d3 [+]:0.0006814      BCM d10[+]:0.0006877      
    BCM d1 [-]:0.000679       BCM d3 [-]:0.0006807      BCM d10[-]:0.000687       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4374 at Tue Apr 29 08:49:31 EDT 2008
    
    Wien angle : -40.2035
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 1.00699
    Left Arm arm angle : 12.4507
    Right Arm D1 momentum : 0.459614
    Right Arm arm angle : 104.998
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : 0.585938
    Left Arm Bottom VDC Current : -3.56445
    -----
    Left Arm Q1 momentum : 1.00704
    Left Arm Q1 power supply : 757.679
    Left Arm Q1 gauss meter : -0.06393
    Left Arm Q2 gauss meter : 0.17149
    Left Arm Q2 power supply current : 433.613
    Left Arm Q2 momentum : 1.007
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 334.433
    Left Arm D1 momentum : 1.00698
    Left Arm D1 NMR : 0.372841
    Left Arm Q3 gauss meter : -0.2035
    Left Arm Q3 power supply current : 400.819
    Left Arm Q3 momentum : 1.00678
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.459677
    Right Arm Q1 power supply : 345.647
    Right Arm Q1 gauss meter : -0.008724
    Right Arm Q2 power supply current : 197.777
    Right Arm Q2 momentum : 0.459555
    Right Arm Q2 gauss meter : 0.10405
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 158.186
    Right Arm D1 momentum : 0.459612
    Right Arm D1 NMR : 0.170556
    Right Arm Q3 power supply current : 182.887
    Right Arm Q3 momentum : 0.45962
    Right Arm Q3 gauss meter : 0.08185
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 390
    BigBite magnet current readback : 388.1
    BigBite Gaussmeter readback : -0.3178
    -----
    Average current of the two cavities : 2.93801
    Current on Unser monitor : 13.6458
    Current on Upstream bcm : 2.89267
    Current on Downstream bcm : 2.98334
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 80.1672
    Hall C Current : 79.23
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5710.71
    Delta(E)/E width (MV_AI_DXWID) : 1.29032
    IPM1C12.XPOS : -0.0116329
    IPM1H04A.XPOS : -0.781396
    IPM1H04A.YPOS : 0.796049
    IPM1H04B.XPOS : -1.2917
    IPM1H04B.YPOS : 1.72085
    -----
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.249512
    HacL_HPE1313A:0_Ch55 : 24.2188
    HacL_HPE1313A:0_Ch54 : 0.174805
    -----
    Right Arm Collimator : -0.00854492
    HacR_HPE1313A:0_Ch58 : -0.575195
    HacR_HPE1313A:0_Ch55 : 22.7051
    HacR_HPE1313A:0_Ch54 : -0.833008
    -----
    Wien angle : -40.2035
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -934.12
    Wien field : 26.736
    Laser attenuation Hall A : 97
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.41491
    SLI vert. size mm : 0
    SLI y position : 2.39624
    -----
    Target : L1 6cm
    fan frequency loop 1 : 31.5
    fan frequency loop 2 : 16
    Encoder position : 3.13948e+07
    Target type : 3.13948e+07
    temperature loop 1(1) : 20
    temperature loop 1(2) : 19.99
    temperature loop 1(3) : 20.29
    Heat exchange LH : 22.4
    temperature loop 2(1) : 23.55
    temperature loop 2(2) : 89.2
    temperature loop 2(3) : 119.99
    Heat exchange H2 : 22.4
    Heat exchange D2 : 24.1
    HPH H2 loop 1 : 34.6988
    HPH D2 loop 2 : 0.000113315
    -----