    keyword=End_of_Run_4375
    ****************************
     Run Number: 4375
     End of Run Comment:
    Run_type=Production,target_type=Loop 1 LH2 6 cm,beam_e0=1.1923,beam_raster=off,leftarm_p=1.007,leftarm_theta=12.5,leftarm_colli=out,bbarm_i=390,bbarm_theta=48,bbarm_colli=out,comment_text=Production Kinematic E
     
    
    PRESCALE FACTORS:ps1=43900   ps2=78000   ps3=4500   ps4=130   ps5=1   ps6=1   ps7=3700   ps8=100   
    
    EVENTS   : [0]: 1006903      [+]: 496529       [-]: 495567       
    TIME     : [0]: 8.969 mins  [+]: 4.450 mins  [-]: 4.452 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -4.59147 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  18.54%      [+]:  19.29%      [-]:  19.24%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.7/379871.9 Hz   T2[0] : 8.7/675512.2 Hz   T3[0] : 8.8/39528.7 Hz   T4[0] : 8.5/1107.2 Hz   T5[0] :1358.7/1358.7 Hz   T6[0] :2244.5/2244.5 Hz   T7[0] : 8.8/32654.3 Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] : 8.7/380599.9 Hz   T2[+] : 8.7/676796.8 Hz   T3[+] : 8.8/39612.0 Hz   T4[+] : 8.5/1109.0 Hz   T5[+] :1362.8/1362.8 Hz   T6[+] :2251.2/2251.2 Hz   T7[+] : 8.8/32719.3 Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] : 8.7/379946.4 Hz   T2[-] : 8.7/675696.3 Hz   T3[-] : 8.8/39531.1 Hz   T4[-] : 8.5/1108.2 Hz   T5[-] :1358.9/1358.9 Hz   T6[-] :2244.4/2244.4 Hz   T7[-] : 8.8/32661.8 Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   4656/204414467  T2[0] :   4660/363502720  T3[0] :   4726/21270934  T4[0] :   4583/595813   T5[0] : 731111/731111   T6[0] :1207783/1207783  T7[0] :   4749/17571743  T8[0] :   5510/551029   
    T1[+] :   2314/101628340  T2[+] :   2316/180719293  T3[+] :   2350/10577265  T4[+] :   2277/296117   T5[+] : 363895/363895   T6[+] : 601125/601125   T7[+] :   2361/8736749  T8[+] :   2734/273430   
    T1[-] :   2312/101498018  T2[-] :   2314/180503963  T3[-] :   2346/10560250  T4[-] :   2277/296033   T5[-] : 363020/363020   T6[-] : 599562/599562   T7[-] :   2358/8725195  T8[-] :   2735/273549   
    
    AVERAGE CURRENT
    BCM x1 : 2.5632 uA  BCM x3 : 2.5692 uA  BCM x10: 2.5914 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    598.2 ppm     BCM u3 :    720.3 ppm     BCM u10:      757 ppm     
    BCM d1 :    638.3 ppm     BCM d3 :    711.4 ppm     BCM d10:    754.4 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001372       BCM u3 [0]:0.001375       BCM u10[0]:0.001386       
    BCM u1 [+]:0.000682       BCM u3 [+]:0.0006834      BCM u10[+]:0.0006889      
    BCM u1 [-]:0.0006814      BCM u3 [-]:0.0006827      BCM u10[-]:0.0006882      
    
    BCM d1 [0]:0.001387       BCM d3 [0]:0.00139        BCM d10[0]:0.001403       
    BCM d1 [+]:0.0006893      BCM d3 [+]:0.0006913      BCM d10[+]:0.0006977      
    BCM d1 [-]:0.0006887      BCM d3 [-]:0.0006906      BCM d10[-]:0.0006969      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4375 at Tue Apr 29 08:59:01 EDT 2008
    
    Wien angle : -40.2035
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 1.00698
    Left Arm arm angle : 12.4507
    Right Arm D1 momentum : 0.459612
    Right Arm arm angle : 104.998
    HALLA:p : 1192.38
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1192.38
    Left Arm Top VDC Current : -6.15234
    Left Arm Bottom VDC Current : -4.88281
    -----
    Left Arm Q1 momentum : 1.00704
    Left Arm Q1 power supply : 757.679
    Left Arm Q1 gauss meter : -0.06394
    Left Arm Q2 gauss meter : 0.17146
    Left Arm Q2 power supply current : 433.607
    Left Arm Q2 momentum : 1.00698
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 334.432
    Left Arm D1 momentum : 1.00698
    Left Arm D1 NMR : 0.372841
    Left Arm Q3 gauss meter : -0.2035
    Left Arm Q3 power supply current : 400.819
    Left Arm Q3 momentum : 1.00678
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.459677
    Right Arm Q1 power supply : 345.647
    Right Arm Q1 gauss meter : -0.008738
    Right Arm Q2 power supply current : 197.777
    Right Arm Q2 momentum : 0.459553
    Right Arm Q2 gauss meter : 0.10407
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 158.187
    Right Arm D1 momentum : 0.459613
    Right Arm D1 NMR : 0.170557
    Right Arm Q3 power supply current : 182.887
    Right Arm Q3 momentum : 0.45962
    Right Arm Q3 gauss meter : 0.08185
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 390
    BigBite magnet current readback : 388.1
    BigBite Gaussmeter readback : -0.3177
    -----
    Average current of the two cavities : 2.94923
    Current on Unser monitor : 14.0871
    Current on Upstream bcm : 2.90044
    Current on Downstream bcm : 2.99801
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 79.9736
    Hall C Current : 79.8
    MBSY1c magnet current (amp) : 49.4539
    MBSY1c Bdl : 297794
    Hall A momentum (Tiefenbach) (HALLA:p) : 1192.38
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1193.56
    Hall A energy (halla_MeV) : 1192.38
    Hall C energy (hallc_MeV) : 5710.71
    Delta(E)/E width (MV_AI_DXWID) : 1.26964
    IPM1C12.XPOS : 0.00154361
    IPM1H04A.XPOS : -0.778862
    IPM1H04A.YPOS : 0.780803
    IPM1H04B.XPOS : -1.28094
    IPM1H04B.YPOS : 1.71558
    -----
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.249023
    HacL_HPE1313A:0_Ch55 : 24.2676
    HacL_HPE1313A:0_Ch54 : 0.173828
    -----
    Right Arm Collimator : -0.00834961
    HacR_HPE1313A:0_Ch58 : -0.574219
    HacR_HPE1313A:0_Ch55 : 22.7539
    HacR_HPE1313A:0_Ch54 : -0.834473
    -----
    Wien angle : -40.2035
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -934.12
    Wien field : 26.736
    Laser attenuation Hall A : 98
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Cycle Rate Set : 30 Hz
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.41491
    SLI vert. size mm : 0
    SLI y position : 2.38873
    -----
    Target : L1 6cm
    fan frequency loop 1 : 31
    fan frequency loop 2 : 15.5
    Encoder position : 3.13948e+07
    Target type : 3.13948e+07
    temperature loop 1(1) : 20
    temperature loop 1(2) : 19.99
    temperature loop 1(3) : 20.3
    Heat exchange LH : 22.4
    temperature loop 2(1) : 23.58
    temperature loop 2(2) : 95.14
    temperature loop 2(3) : 119.99
    Heat exchange H2 : 22.4
    Heat exchange D2 : 24.1
    HPH H2 loop 1 : 35.3235
    HPH D2 loop 2 : 0.00123869
    -----